Loading...
HomeMy WebLinkAboutInitial Plan IPZR2004025 - Plans'GENERAL NOTES SHEET INDEX 1. THE CONTRACTOR SHALL. FIELD VERIFY ALL CONDITIONS AND DIMENSIONS TITLE SHEET: PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR All WORK AND T-1 TITLE SHEET MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTOR. 2. THE CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERROR. INCONSISTENCY. OR OMISSION THEY MAY DISCOVER WITH THE PLANS, DOCUMENTS. NOTES,LS1 TOPI RAPHHSI)JEY • •OR SPECIFICATIONS PRIOR 10 STARTING CONSTRUCTION. INCLUDING BUT NOT •. • • • LIMITED TO DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR, INCONSISTENCY, OR OMISSION AFTER THE START OF • • • • '4L N,_ ' . EEMy1IEM1y • • • • •• • • ••CONSTRUCTION WHICH HAS NOT BEENBROUGHT TOTHE ATTENTION ireless i •v r n A-1 SITE LAN • • •. ARCHITECT AND SHALL INCUR ANY EXPENSES T TO RECTIFY THE SITUATION. THEEXPENSES • • • •weI7 A-2 ENfA C!D SRC PLAN, EQUIPMENT & ANTENNA LAYOUTS MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY ARCHITECT.mum A-3 ELEVATIONS 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING A-4 ELEVATIONS UTILITIES WHETHER SHOWN HEREIN OR NOT. AND TO PROTECT THEM FROM • • • •• •DAMAGE THE CONTRACTOR OR SUBCONTRACTOR AS MAY BE SPECIFIED IN THE •• • •.•CONTRACT BETWEEN THE CONTRACTOR AND SUBCONTRACTOR SHALL BEAR ALL G 0 E N W E S T COLLEGE • •• •EXPENSES OF REPAIR AND/OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY •• • • • •••DAMAGE BY OPERATIONS ICON JUNCTION WITH THE EXECUTION OF WORK. • •: : : •.. 4. APPROVED PLANS SHALL BE KEPT IN A PLACE ON THE PROJECT SITE.I15744 GOLDENWEST STSPECIFIED BY THE GOVERNING AGENCY AND SHALL NOT BE USED BY WORKMEN.. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION AS APPROVED HUNTINGTON BEACHCA 92647PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN. IN GOOD CONDITION, ONE , COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANCE ORDERS ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE DIRECT CAREOF THE SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY VERIZON WIRELESSWITH ALL REVISIONS. ADDENDA, APEUOR CHANGE ORDERS AT THE CONCLUSION OF THE WORK FOR AS-BUILT RECORD DRAWINGS CONDITIONS OF APPROVAL PROJECT PARTICIPANTS PROJECT DESCRIPTION. 5 THE CONTRACTOR SHALT. BE RESPONSIBLE FOR THE COMPLETE SECURITY CIVIL ENGINEER: SURVEYOR MODIFICATIONS TO AN UNMANNED WIRELESS TELECOMMUNICATIONS OF THE PROJECT AND SITE WHILE THE PROJECT IS IN PROGRESS AND T.B.D.CONNELL DESIGN GROUP SCHMIDT CONSULTING INC.FACILITY CONSISTING OF: UNTIL THE JOB IS COMPLETE.15615 ALTON PARKWAY, SUITE 360 17985 SKYPARK CR., STE G 6. ALL DEBRIS SHALL BE REMOVED FROM THE PROJECT PREMISES AND IRVINE. CA 92618 IRVINE. CA 92614 1. INSTALLATION OF FOUR (4) EQUIPMENT CABINETS AND ONE (1) SHALL BE LEFT IN CLEAN (BROOM SWEPT) CONDITION AT ALL TIMES CONTACT: DAN CONNELL CONTACT: ERICH SCHMIDT GENERATOR MOUNTED @ GRADE. BY EACH TRADE PERFORMING THEIR OWN PORTION OF THE PROJECT TEL- (949) 753-8807 OFFICE PHONE: (949) 955-3070.FAX: (949) 753-8833 OFFICE FAX: (949) 955-3077 2. INSTALLATION OF TWO (2) PANEL ANTENNAS PER SECTOR. THREE 7.1. REFCFERENCE OF DRAWINGS OR DETAILS ARE FOR CONVENIENCE AND DOES NOT EMAIL erichOpcssurveyors.com (3) TOTAL SECTORS, MOUNTED ON AN (E) MONOPOLEOFIO OF ANY DRAWING OR DETAILLIMIT 8. CONTRACTOR SHALL REFER TO, AND CROSS CHECK DETAILS, DIMENSIONS,3. POWER AND TELCO RUNS FROM EQUIPMENT TO SOURCE NOTES. AND REQUIREMENTS SHOWN ON THE DRAWINGS WITH RELATION TO THE STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING AND ANTENNA REQUIREMENTS 9. ARCHITECT MAKES NO GUARANTEE FOR PRODUCTS, FIXTURES, AND/OR EQUIP.LEGAL DESCRIPTIONNAMED BY TRADE OR MANUFACTURER. GUARANTEE OR WARRANTY THAT MAY BE PROVIDED IS SO DONE THROUGH THE COMPANY OR MANUFACTURER PROVIDING PENDING RECEIPT OF TITLE REPORT)(TjPRODUCT. FIXTURE, AND/OR EQUIPMENT ONLY UNLESS PROVIDED BY CONTRACTOR IN WRITTEN FORM ALSO. 10 ALL TRADES SHALL DO THEIR OWN CUTTING. FITTING, PATCHING. ETC. TO MAKE THE SEVERAL PARTS COME TOGETHER PROPERLY. 11. CONTRACTOR SHALL PROTECT ADJOINING PROPERTIES (PUBLIC OR PRIVATE) FROM NOSE, DUST, DIRT, FIRE HAZARD, ETC. PER CITY OR GOVERNING AGENCY REQMTS. 12. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN ENCROACH- MENT PERMIT HAS FIRST BEEN OBTAINED FROM THE LOCAL GOVERNING AGENCY. ABBREVIATIONS PROJECT DATA13. DO NOT SCALE DRAWINGS. ARCHITECT SHALL BE NOTIFIED PRIOR TO BEGINNING CONSTRUCTION OF ANY DISCREPANCIES FOUND.TR APPLICANT:14. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS. TYPICAL EA/C AIR CONDITIONING ELEV. ELEVATION O.C. ON CEN DETAILS AND GENERAL NOTES ARE MINIMUM REQUIREMENTS TO A.C. ASPHALT CONCRETE ENT. ENTRANCE 00. OUTSIDE DIAMETER VERIZON WIRELESS BE USED WHEN CONDITIONS ARE NOT SPECIFICALLY SHOWN OTHERWISE.ALUM. ALUMINUM EQ. EQUAL OPNG. OPENING 15505 SAND CANYON AVENUEARCH. ARCHITECT EQUIP. EQUIPMENT PIAS. PLASTER IRVINE, CA 9261815. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS,0 AT EXIST. EXISTING PLBG. PLUMBING AR) FCONTACT:SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA.R BD. BOARD EXT. EXTERIOR PLYWO. PLYWOOD D (XX XXXXONE: (K%%) XX%-XXXX16. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR DOT. BOTTOM F.S. FACE OF STUD R PROPERTY LANEOR ROOF. LOADS SHALL NOT EXCEED DESIGNED LIVE LOADS PER SQUARE FOOT.BLDG. BUILDING FIN. FINISH RM. ROOM CONSULTANT:PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE STRUCTURE HAS NOT E CENTER LANE GAL GALLON SEC. SECTIONATTAINED DESIGN STRENGTH.CMG, CEILING SIN. SHEET THE PLANNING CONSORTIUM17. ALL CONSTRUCTION MATERIALS, TECHNIQUES, AND FINISHES SHALL BE AS CONC. CONCRETE GA GAUGE SIM. SIMILAR & COUNTRY ROAD1111 TOWNREQUIRED BY THE APPROPRIATE CODE AUTHORITIES, INSTALLATION SHALL P.BD.GY UM BOARD TR)ST ORANGE. CACFOLLOW THE MANUFACTURERS PUBLISHED SPECIFICATIONS AND/OR TRADE HS TRUCTURALSTRUCT SDIA. DIAMETER HT 0 ACT: FLO MEADSTANDARDS IN ADDITION TO MEETING OR EXCEEDING THE DESIGN STANDARDS.SUP. SUSPENDEDCENDEDM.H.METALHOLLOW 0327714) 569PHONE:18. ALL ITEMS, CONSTRUCTION FINISHES, EOUIPMENT,ETC. INDICATED TO BE P TYPICALNSODIM. DIMENSION HORIZ.HORIZONTAL FAX: ( 714 569-0327REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND AT. JOINT U.O.O UNLESS. OTHERWISEON. DOWNWSHALL BE REMOVED FROM THE SITE WITH THE EXCEPTIONS BELOW: B: ITEMS NOTED TO RETURNEDOWNER DWG. DRAWING MAX. MAXIMUM NOTED PROPERTY OWNER:BE RE B: ITEMS THAT ARE NOTED TO TO BE REMOVED BY OWNER.D.F. DRINKING FOUNTAIN MECH. MECHANICAL PERT. VERTICAL (E) EXISTING WW MICROWAVE VCT VINYL COMPOSITION OWNER: COAST COMMUNITY COLLEGE19. EXCEPT AS NOTED ON PLANS AND/OR DETAILS NEW CONSTRUCTION ADDED TO U EACH MIN. MINIMUM TILE ADDRESS: 2701 FAIRVIEW RDEXIST. SHALL MATCH EXIST. IN FORM, TEXTURE, MATERIALS AND OTHER RESPECTS.ELEC. ELECTRIC(AL) N.1 C. NOT IN CONTRACT W/ WITH COSTA MESA, CA 92626 0. THE BUILDING INSPECTOR SHALL BE NOTIFIED PRIOR TO ANY COMMENCEMENT EL ELEVATION N T.S. NOT TO SCALE WD.WOOD CONTACT: N/AOF CONSTRUCTION. AS MAY BE REQUIRED BY LOCAL GOVERNING AGENCY.NO./+NUMBER PHONE• (714) 438-4600 1. CONTRACTOR AND OWNER ARE TO VERIFY ALL NOTES, DIMENSIONS, DRAWINGS.FAX: TBD SPECIFICATIONS, ETC. PRIOR TO THE START OF CONSTRUCTION. 2. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS PROJECT ADDRESS: AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT.VICINITY MAP 15744 GOLDENWEST ST. BUILDING PERMIT APPLICATION WILL BE FILED BY VERIZON. CONTRACTOR HUNTINGTON BEACH, CA 92647 SHALL OBTAIN PERMIT AND MAKE FINAL PAYMENT FOR SAID DOCUMENT. \3. CONTRACTOR SHALL PROVIDE LIST OF SUBCONTRACTORS USED ON THE PROJECT ROLSA AVE.1 AND LIEN RELEASES FOR EACH SHOWING THAT EACH HAS BEEN PAID IN FULL.MUNICIPALITY: 4. ALL REQUIRED PERMITS MUST BE OBTAINED AND KEPT ON THE CONSTRUCTION JURISDICTION CRY OF HUNTINGTON BEACH SITE WITH THE AGENCY APPROVED PLANS, LOCATED PER CITY OR LOCAL LEASE AREA. ±600 SF. GOVERNING AGENCY. ALL APPROVED PLANS, PERMITS, INSPECTION CARDS o CODE: CBC 2001 EDITION TO BE RETURNED TO VERIZON UPON COMPLETION AND FINAL INSPECTION.CONSTRUCTION TYPE: V-IHR 25 ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH IT OCCUPANCY: B DESIGN CONCEPT 10 THE PROJECT. ARCHITECTS REV'IEW OF A SEPARATE DENT "A E;S CUN.RENT 2GUI,NG. P-PUBLIC P N: 142-012-01ASHALL NOT INDICATE REVIEW OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS.. 26. FIRE EXTINGUISHER REQUIREMENTS SHALL BE VERIFIED WITH THE LOCAL FIRE MARSHALL Geodetic Coordinates: 7. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL 44' 12.3'(1 2LATITUDE:83)REMEDY ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP 1 13'1 118 00' 21LONGITUDEOR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE (1) YEAR AFTER THE . COMPLETION AND ACCEPTANCE OF THE PROJECT UNDER IRS CONTRACT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN VERIZON AND CONTRACTOR. 8. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LOCAL CODE REGULATIONS AND STATE DEPARTMENT OF INDUSTRIAL REGULATIONS, DIVISION OF INDUSTRIAL SAFETY (O.S.HA) IEONREMENR E CONTR T R E PRT TTAHAC9.O SHALL PROVIDE DEQUAT OECION FOR THE SAFETY OF THE OWNER'S EMPLOYEES AND WORKMEN AND ALL OTHERS AT ALL PROPRIETARY INFORMATION NOT FOR USE OR DISCLOSURETIMES DURING CONSTRUCTION OF THE PROJECT.OUTSIDE VERIZON WIRELESS EXCEPT UNDER WRITTEN AGREEMENT z W O W - E- o u W Z Z 0 0t tt N N 0 1• C K- 0 0 0 ° ° ° +W7 i R$DD T-1 sh.d 4 t T BASE EL. 05' A6L (270 AM$L) GRAPE EL. 00' A61 (263 AM SL) BASEBALL FIELD 589'32'37E --_-----_1241 53' EDINGER AVENUE 100' R/W GRAPHIC SCALE ( IN FEET ) 1 inch • 200 fL MCFADDEN AVENUE -- 807/w--- R=30 00 ---- L=470 A=89'49'02• R=540 00 L=42_412 A= 45'00'OO• R•46000 L=36124 5=44.59'42 IN TOP eR ANTENNAS. 1150' AOL (11415 AM5L)Do TOP OP I'ONOPOIE EL•1120'A64, (1565AMSL) I I I ) ,A,012,3 „ o11 w 10 Q P F IV I 'I' R BOUNDARY DETAIL SCALE, 1" = 200' 20 NAG -N SIDEWALK LEGEND •It •.W ,I .IINx WI VYR6 VERTICAL CURB W C4MR R/IY OF w4Y AP ASPHALTD/w ACCESS DRIVEWAY TOP TOP C( SLEPT ltt T OF IBM TEMPORARY B BENCHMARK5W TP T TOP OP OP OF P0APEI IOU TOP WALL ® LOT .... ER BENLNMARA OR POSITION HRCEWETIC COORMNAIES .+'T' SPOT ELEVATOR •_ _ _-__ _ C.A. RNVEDLIN LVEE At Lux ON FEAL DISK ANRIMA Cw IRON D[NT MA[ M 8+F6[D MICROWAVE ANTENNA WIRE LAG[Hxxxxxxxxxxxw RAKROAD TRAQS FM.WN.W•L •WL MM•••AP POSITION OF GEODETIC COORDINATES LATITUDE 33' 44 12 1- NORTH LONGITUDE 118' 50' 21 3' WEST (NAD83)ELEVATION 26 5' (NAVD BB) 1120 MONOPOLE & POSITIONOF GEODETIC COORDINATES13. 20' (SEE VERTICAL DETAIL) NAG-N • 11 •tl11. L • 41. W W 5A WATER CONTROL VALVE O FIRE HYDRANT W, TIRE® FOUND AS NOTED '0j POWER POIE 0 LIGHT PPE0 ELECTRICAL TRANSFORMER NO AIR CONPRONING UNIT TELEPHONE PEDESTAL DID TELEPHONE VAU LT(1 TE LE-E .-OE CAS VA LA M CAS METER 70' GATE B 0' GATE UNIDENTIFIED VAULT POWER POLE NO 1680670E 80' CHAIILINK FENCE 80' CATE 1!FNA11 (URBANE DEPOSIT CQUIPMENT 120' BUILDING GARBAGE DEPOSIT EQUIPMENT FENCED AREA W/ 6' WROUGHTIRON FENCE BO' EMU WALL 10 0' CHAINLI CONCRETE 1 BUILDING MECHANICAL EOIPMENT (NOT SHOWN) ASPHALT BENCHMARK PROJECT FOUND ORANGE COUNTY ALUMINUM DISK STAMPED 'HB-256-83' LOCATED AT THE NORTHEASTERLY CORNEROF THE INTERSECTION OF COLDENWEST STREET AND EDINGER AVENUE ELEVATION- 22 46 FEET (NAVDEN DATUM) BASIS OF BEARING BEARINGS SHOWED HEREON ARE BASED UPON US STATE PLANE NAD83 COORDINATE SYSTEM UIIFONNU STATEFLWECOORDALLTEIOMEI. DETERMINE BY CPS C'Y'EPVA'r.N: '6URVEY DATE 10/20/04 SURVEYOR'S NOTE FIE PEPrlT ISR$ 1111 --1,,^ Al Tin TIVE 1.15 LRVEY WAS FESFOPM[D A'.Y EAIW'LNI> Un VIIILI ITEMS CONTAINED WITHIN THE TITLE REPORT WHICH MAY AFFECT THE LEASE AREA HAVE NOT BEEN PLOTTED THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONS TITUTE A BOUNDARY SURVEY OF THE PROPERTY UTILITY NOTES SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS IT IS THERESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY 07HER INVOLVED AGENCIES 70 LOCATE ALL UTILITIES PRIOR 70 CONSTRUCTION REMOVAL. RELOCATION AND/ ORREPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR 50' R/W TAKE 1-405 NOR/SAN DIEM FWY TOWARDS LONG BEACHTAKE THE BEACH BLVD/CA-39 NORTH EXIT TOWARDS WESTMINSTER CONTINUE ON CA-39 NORTH TURN LEFT ON 1CFADDEN AVE. TURN LEFT COLDENIMEST ST ? B _u o WZaW GOLDENWEST STREETf9nOD 0O 1 0<ZYOOrn<DCJZ183'-11-110ZRENSIONS000DLEASE EXH181Tvpc001V/25104ISSUED FOR REVIEWJDW002111904ISSUED FOR ZONING0004194ISSUED FOR ZONINGLrcGOLDENWEST COLLEGE15744 GOLDENWEST STREETHUNTINGTON BEACH. CA 92647COUNTY OF ORANGESheet TileSITE PLANveriZen wireless15505 SAND CANYON AVE.IRVINE, CA. 92618(949) 286-7000CNn En9o.el@0Job J. 04-719 CortenoelCONNELL DESIGN GROUPS LL.CCONSULTING CIVIL ENGINEERSJSEIS 4LTONPIIMT. SURE J4A IRtWE C4 92618099171J3W17 OFFICE-9191 »J-WJF XDEPT APPROVED DATEA&CRERETNTE INOPSEE\DUT d' t SECTOR'G'(E) SHELTER (BELOW) 0°1 .. •..• . • (E) NEXTELMONOPOLE '' •f•(E) BLOC •• •••• SECTORG0° •(E) TREE TO REMAIN • • • • • • • •• ••• (N) CABLE BRIDGE (BELOW)(E) GATE (N) VERIZON PANEL ANTENNAS (2 ANTENNAS PER SECTOR.II'-D' VERIZON WIRELESS LEASE AREA 3 SECTORS TOTAL) (N) 8' HIGH CHAIN LINK FENCE SECTOR'B'SECTOR'A'------------------x- I 240°120°N I I I IxI "(E) STOOP I i I 1 (E) CURB T BE REMOVED - - - - - - - - - - - - - - -1 I xl•I ANTENNA LAYOUT PLAN 1.' SCALE 2 ()x1 (E) SHED TO BE REMOVED, EXACT0 1 r iyE ,O'LOCATION TO CI I 1 ETERMINED BYD OWNER I x PROPOSED VERIZON I l EMERGENCY PROPOSED vER120N I` GENERATOR MOUNTED ON CONCRETE PADGPS ANTENNA I i I xI InI (E) CHAIN LINK FENCE I I I TO BE REMOVED PROPOSED VERIZON M' I 1 IxI ICABLE BRIDGE I I I W (E) CHAINUNN FENCE W W I xl I (E) NEXTEL SHELTER a I (1 w _L -- - - - - - - - - - -J IxI o ON /I SED VERIZONPRPwIOOCPNTENNA EDGE OF PAVEMENT J ix -I pa 1 I w I IIN°/x I w I 8 PROPOSED VERIZON I EOUIPMENT CABINETS MOUNTED ON (E) MONOPOLE >I I °- •o I IIxI (E) BLDGE`- / CONCRETE PAD. 4 I 2 /TOTALw Iw "' I xI (N) VERIZON PANEL ANTENNAS I I I SECTOR. (EC PROPOSED VERIZONSTORS TOTAL)3 i w IPMENT CABINETSEQU DE w e I I IxI MOUNTED ON CONCRETPAD10TAL / P ROPOSED VERIZON I x( e I E CTRICAL TRANSFORMER wI i/I I (E) BLDG MOUNTED ON ( , I 001 /CONCRETE PAD I oo /IxI I I w/ lwI/xg//I PROPOSED VERIZON I ELECTRICAL I I TRANSFORMER I I MOUNTED ON o w W " w x 1 CONCRETE PAD Y 3'-Y PROPOSED VERIZON TFTELCO PnXES i&E - EI.•, •IIED 10 (El I All `l 11 l I T&E r / GLOLN WALL / 1 JJ 'IIIVVV///" (E) CNU BLOCK WALL PROPOSED VERIZON E CMU B WALL SECTOR B 'PROPOSED VERIZON CABLE BRIDGE ELEC/TELCO BOXES MOUNTED (E) CMU - N - ()LOCK 2400 BLOCK WALLLLAF*SECTOR'A'(E) CNAINUNK FENCE 120° EQUIPMENT LAYOUT PLAN A`3 NLARGED SITE PLAN 1,®0 E ,3/I 0, 9 0 Q ^ C K W W B- (y Odd zq 7 zV Flu CA Z a.o Z=zs Fw z w 0 .°' Cp w PSpS Shoot I A-2 T.0 E XTE ANTENNAS L0. E NEXTEL ANTENNAS (E) NEXTEL ANTENNAS (E) NEKTEL ANTENNAS • • • ••• • •• •••• • • • • ••• • •• • • • • •••• •••••• • 00 0 0 :0:9 9 .. •••• •• • (E) MONOPOLE • •••• •• • (E) MONOPOLE PROPOSED VERIZON ANTENNA CENTERLINE PROPOSED VERIZON ANTENNA CENTERLINE o (N) VERIZON PANEL ANTENNAS a (2 ANTENNAS PER SECTOR. PROPOSED YER20N ANTENNA CENTERLINE_(N) VERIZON PANEL ANTENNAS (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL)PROPOSED VERIZON ANTENNA CENTERLINE M O M I 'Q^ I 3 SECTORS TOTAL) M H 0IOIN ^ (C) NEKTEL SHELTER (C) NEXTEL SHELTER PROPOSED VERIZON CABLE BRIDGE PROPOSED VERIZON CABLE BRIDGE (E) 6' HIGH CHAINLINK FENCE PROPOSED VERIZON CPS ANTENNA PROPOSED VER IZON CPS ANTENNA PROPOSED VERIZON PROPOSED VERIZON EQUIPMENT EQUIPMENT CABINETS MOUNTED ON CONCRETECABINETS MOUNTED ON CONCRETE PAD. 4 TOTAL M PAD. 4 TOTAL M 0 PROPOSED VERIZON 0 EMERGENCY GENERATOR 'ol (E) BUILDINGS TO MOUNTED ON CONCRETE PAD REMAIN (E) 8' HIGH CMU BLOC (E) 8' HIGH CMU BLOCK WALK WALL. BEYOND ._LEIBUILEANOS TO REMAIN TO E NEKTEL SHELTER ---Z -i ' -' -' -(T [ '-rTTTIT TO E FENCE 1 - - - -'_..-. I-IT , 0 0 -H SOUTH EL VATI NEO xAL 2 NORTH ELEVATION •w _ 5 0 B z z G z z t C N N B KI0 0 00o W 0 W 6 S n A-3 a TO E NEXTEL ANTENNAS lqw T0. C NEXTEL ANTENNAS TO F MONOPOLE • ••(E) NEXTEL ANTENNAS (E) NEXTEL ANTENNAS • •• •• •• • •• • ••••• 000 *so • 0 00:0 : •• ••(E) MONOPOLE (E) MONOPOLE • • •• ••••• PROPOSED VERIZON ANTENNA CENTERLINE PROPOSED VERIZON ANTENNA CENTERLINE o PROPOSED VERIZON ANTENNA CENTER LINE- - - - - (N) VERIZON PANEL ANTENNAS (2 ANTENNAS PER SECTOR. a PROPOSED VERIZON ANTENNA CENTERLINE -_ -_-(N) VERIZON PANEL ANTENNAS(2 ANTENNAS PER SECTOR. A 'I H o 3 SECTORS TOTAL) x M 0 a 3 SECTORS TOTAL) ((F)) NNE%TEL SHELTER.D BEYON PROPOSED VERtZON CABLE BRIDGE a N 4I PROPOSED VERIZON EQUIPMENT CABINETS MOUNTED ON CONCRETE,N PAD, 4 TOTAL h PROPOSED VERIZON GPS 0I ANTENNA (E) NEXTEL SHELTER (E) 6- HIGH CHAINLINK FENCE. BEYOND ILL fi HI'?I LHAINLIIIK UiGE--- PROPOSED VERIZON EMERGENCY GENERATOR MOUN'EO ON CONC°ETE PAD (E) BUILDINGS IN To. (E) NEXTEL SHELTER FOREGROUND LEFT OFF FOR CLARITY TO E NEXTEL SHELTER T.O. E BLOCK WALL TO E FENCE EAST ELEVATION 2 W S 13C AL m,E T ELEVATION 221 B Sheet I A-4