Loading...
HomeMy WebLinkAboutInitial Plan; Zoning Review IPZR2012001 - Notice of action Letter with Findings & Conditions of Approval1 . • Plannin Division 714.536.5271 February 22, 2012 Application: Applicant: Property Owner: Request: Project Location Dear Mr. Santillan: Cit of Huntin ton Beach 2000 MAIN STREET Initial Plan Zoning & Review No. 2012-001 ,(Evangelical Free Church Addition) Buildin Division 714.536.5241 Michael Santillan, 19891 Beach Boulevard #239, Huntington Beach CA 92648 Evangelical Free Church, 19891 Beach Boulevard #205, Huntington Beach CA 92648 To review conceptual plans for the addition of classrooms, administrative offices, and a multi-purpose building to an existing church facility. 1912 Florida Street, 92648 (east side of Florida Street, south of Utica Avenue) We appreciate the opportunity to review your conceptual plans submitted on January 24, 2012 for the proposed addition to the church facility. The following comments provided in this letter reflect Planning review only and should be considered preliminary, subject to change upon receipt of any new information and/or submittal of an entitlement application. Zonin /General Plan: 1. The project is located within RM (Residential Medium Density) zoning district which allows for religious assembly uses. The project shall comply with the development standards within Chapter 210 of the Huntington Beach Zoning and Subdivision Ordinance (HBZSO). The HBZSO may be found online htt ://www.huntin tonbeachca. ov/ overnment/elected officials/cit clerk/zonin code/ index.cfm . CALIFORNIA 92648 DEPARTMENT OF PLANNING AND BUILDING www.huntin tonbeachca. ov 2. The General Plan designation for the subject property is RM-15 (Residential Medium Density - 15 dwelling units/acre). IPZR No. 12-001 • • February 22, 2012 Page 2 Re uired Entitlements: Based upon the proposed project, the following submittals are applicable: 1. An Entitlement Plan Amendment (EPA) application and a hearing before the City of Huntington Beach Planning Commission; the current application fee is $3,910. The application shall include the request to amend EPA No. 01-005, CUP No. 97-106, and CUP No. 87-037 to permit the addition of classrooms, administrative offices, and a multi- purpose building to an existing church facility. 2. The appropriate environmental review process will be determined after the submittal of the project. Code Re uirements Based on the preliminary review of conceptual plans for conformance with the development standards in the RM zoning district, the following issues have been identified. Please note that changes to your plans and receipt of new information will be reviewed for zoning compliance during entitlement processing and/or plan check. The code requirements applicable to your proposed project include: 1. Pursuant to HBZSO Section 210.06, the minimum front setback is 15 ft. The plans show the front setback is at 10 ft. The existing church building is considered a non-conforming structure as it relates to the front setback. Pursuant to HBZSO Section 236.06(E), the area of enlargement to a nonconforming structure in any five year period shall not exceed 50% of the area of the structure as it exists on the effective date of this ordinance. The existing building is approximately 11,729 sq. ft. and the proposed addition is approximately 8,967 sq. ft. (76% of the existing structure). Therefore, the addition to the structure exceeds the maximum allowable addition of 50%. 2. Pursuant to HBZSO Section 210.06(D), the minimum spacing between buildings shall be 10 ft. The plans do not show the building separation. The plans shall be amended to identify the minimum building separation. 3. Pursuant to HBZSO 230.76(A), all exterior mechanical equipment shall be screened from view on all sides. Equipment to be screened includes heating, air conditioning, refrigeration equipment, plumbing lines, ductwork, and transformers. The plans show mechanical equipment along the north property lines. The plans shall be provide the proper screening for mechanical equipments. 4. Pursuant to HBZSO Section 231.04(B), off-street parking spaces shall be provided in accord with the parking requirement (Schedule A). According to the schedule, the required parking will be calculated with the following rates: religious assembly use 1/35 ft. of public assembly area school use - preschools 1/staff member and 1/classroom - elementaryfjunior high 1.5/classroom - high school/college 7/classroom IPZR No. 12-001 February 22, 2012 Page 3 Based on the parking rates above and the proposed schedule of activities, the maximum required number of parking spaces for the site is 112 spaces. The proposed provision of 155 parking spaces (onsite and off-site) complies with the parking requirement. However, the parking requirement may change based on the proposed schedule of activities. 5. Pursuant to HBZSO Section 232.08(B), non-residential development shall have one 36- inch box tree for each 45 lineal feet of street frontage planted within the first 15 feet of the setback area adjacent to a street. The plans do not show the number of trees within the first 15 feet of the setback area adjacent to a street. Based on the site frontage of approximately 285 feet, seven 36-inch box trees within the first 15 feet of the front setback area will be required. Please provide the proper location, number of trees, and tree sizes as specified above. Desi n Guidelines The Huntington Beach Urban Design Guidelines do not include guidelines specific to religious assembly uses in the RM zoning district. The following guidelines for non-residential projects have been identified to ensure quality project design and compatibility with the surrounding uses. These guidelines include: 1. Establish attractive, inviting, imaginative and functional site arrangement of buildings and parking areas and high quality architectural and landscape design which provides for proper access, visibility an identity. Chapter 4.B. 2. The designer is expected to employ variations in form, building details and siting in order to create visual interest. In all cases, the selected architectural style should be employed on all building elevations. Chapter 4.D.1.d. 3. Buildings should be divided in distinct massing elements. Building facades should be articulated with architectural elements and details. Vertical and horizontal offsets should be provided to minimize building bulk. Chapter 4.D.2.a. 4. Vertical architectural elements such as towers should be used as focal points. Chapter 4. D.2. h. 5. Developments should incorporate plazas and courtyards into their design. Courtyards should be buffered from the street, parking areas and drive aisles. Chapter 4.C.7.a. and e. 6. Vertical building focal elements are encouraged. Towers, spires or domes become landmarks and serve as focal/orientation points for the community. Chapter 5.D.15. Other Relevant Information The following is provided for your information: There are several reciprocal parking agreements that affect the use and parking requirements of the properties located at 19891 Beach Boulevard and 1912 Florida IPZR No. 12-001 • • February 22, 2012 Page 4 Street. As part of the proposed addition to the church facility, information needs to be submitted to address these reciprocal parking agreements in terms of applicability and impact on future development. Thank you for submitting your Initial Plan Zoning & Review application. Please call me at (714) 374-1744 or via email at to u en surfcit -hb.or if you have any questions regarding the information in this letter or would like more information on the entitlement application process or submittal requirements. Sincerely, Tess aqzl'-' TESS NGUYEN Associate Planner Copy: Herb Fauland, Planning Manager Evangelical Free Church, Property owner Project File