Loading...
HomeMy WebLinkAboutAdministrative Permit APX2016001 - Project Implementation Code RequirementsLg @ HUNTINGTON BEACH PLANNING DIVISION HUNTINGTON BEACH PROJECT IMPLEMENTATION CODE REQUIREMENTS DATE: MARCH 22, 2016 PROJECT NAME: BLASINGAME RESIDENCE PLANNING APPLICATION NO.PLANNING APPLICATION NO. 16-020 ENTITLEMENTS: ADMINISTRATIVE PERMIT NO. 16-001 DATE OF PLANS: JANUARY 19, 2016 PROJECT LOCATION: 16381 S. PACIFIC AVE., 90742 PLAN REVIEWER: TELEPHONEIE-MAIL: PROJECT DESCRlPTlON:_ KIMO BURDEN, PLANNING AIDE (714)-536-5438 I kimo.burden@surfcity-hb.org To "approve in concept” the demolition of an existing two-story single- family residence and to construct a new three-story 3,915 sq. ft. single- family residence with a 600 sq. ft. attached garage. The following is a list of code requirements deemed applicable to the proposed project based on plans stated above. The list is intended to assist the applicant by identifying requirements which must be satisfied during the various stages of project permitting and implementation.A list of conditions of approval adopted by the Community Development Department in conjunction with the requested entitlement(s), if any, will also be provided should final project approval be received. If you have any questions regarding these requirements, please contact the Plan Reviewer. ADMINISTRATIVE PERMIT NO. 16-001: 1. During demolition, grading, site development, and/or construction, the following shall be adhered to: a. b. The site plan shall include all utility apparatus, such as but not limited to, backflow devices and Edison transformers. Utility meters shall be screened from view from public right-of-ways. Electric transformers in a required front or street side yard shall be enclosed in subsurface vaults. Backflow prevention devices shall be not be located in the front yard setback and shall be screened from view. (HBZSO Section 230.76) All exterior mechanical equipment shall be screened from view on all sides. Rooftop mechanical equipment shall be setback a minimum of 15 feet from the exterior edges of the building. Equipment to be screened includes, but is not limited to, heating, air conditioning, refrigeration equipment, plumbing lines, ductwork and transformers. Said screening shall be architecturally compatible with the building in terms of materials and colors. If screening is not designed specifically into the building, a rooftop mechanical equipment plan showing proposed screening AP No. 16-001 March 22, 2016 Page 2 of 3 2. 6. 7. C. d. must be submitted for review and approval with the application for building permit(s). (HBZSO Section 230.76) The site plan and elevations shall include the location of all gas meters, water meters, electrical panels, air conditioning units, mailboxes (as approved by the United States Postal Service), and similar items. If located on a building, they shall be architecturally integrated with the design of the building, non-obtrusive, not interfere with sidewalk areas and comply with required setbacks. (HBZSO Section 230.76) All parking area lighting shall be energy efficient and designed so as not to produce glare on adjacent residential properties. Security lighting shall be provided in areas accessible to the public during nighttime hours, and such lighting shall be on a time-clock or photo-sensor system. (HBZSO 231.18.C) Prior to issuance of demolition permits, the following shall be completed: 8. b. c. d. The applicant shall follow all procedural requirements and regulations of the South Coast Air Quality Management District (SCAQMD) and any other local, state, or federal law regarding the removai and disposal of any hazardous material including asbestos, lead, and PCB’s. These requirements include but are not limited to: survey, identification of removal methods, containment measures, use and treatment of water, proper truck hauling, disposal procedures, and proper notification to any and all involved agencies. (AQMD Rule 1403) Pursuant to the requirements of the South Coast Air Quality Management District, an asbestos survey shall be completed. (AQMD Rule 1403) The applicant shall complete all Notification requirements of the South Coast Air Quality Management District. (AQMD Rule 1403) The City of Huntington Beach shall receive written verification from the South Coast Air Quality Management District that the Notification procedures have been completed. (AQMD Rule 1403) During demolition, grading, site development, and/or construction, the following shall be adhered to: 3.All Huntington Beach Zoning and Subdivision Ordinance and Municipal Code requirements including the Noise Ordinance. All activities including truck deliveries associated with construction, grading, remodeling, or repair shall be limited to Monday - Saturday 7:00 AM to 8:00 PM. Such activities are prohibited Sundays and Federal holidays. (HBMC 8.40.090) The structure(s) cannot be occupied, the final building permit(s) cannot be approved, and utilities cannot be released until the following has been completed: a. b. C. Complete all improvements as shown on the approved grading, landscape and improvement plans. (HBMC 17.05) All trees shall be maintained or planted in accordance to the requirements of Chapter 232. (HBZSO Chapter 232) The provisions of the, Water Efficient Landscape Requirements shall be implemented. (HBMC 14.52) ‘ I a AP No. 16-001 March 22, 2016 Page 3 of 3 9. 10. 11. 12. 13. 14. 15. The Development Services Departments (Community Development, Fire, and Public Works) shall be responsible for ensuring compliance with all applicable code requirements and conditions of approval. The Director of Planning may approve minor amendments to plans and/or conditions of approval as appropriate based on changed circumstances, new information or other relevant factors. Any proposed plan/project revisions shall be called out on the plan sets submitted for building permits. Permits shall not be issued until the Development Services Departments have reviewed and approved the proposed changes for conformance with the intent of the Community Development Department action. If the proposed changes are of a substantial nature, an amendment to the original entitlement reviewed by the Community Development Department may be required pursuant to the provisions of HBZSO Section 241.18. (HBZSO Section 241.18) Administrative Permit 16-O01 shall become null and void unless exercised within one year of the«date of final approval, or as modified by condition of approval. An extension of time may be granted by the Director pursuant to a written request submitted to the Community Development Department a minimum 30 days prior to the expiration date. (HBZSO Section 241.16.A) Administrative Permit No. 16-001 shall not become effective until the appeal period following the approval of the entitlement has elapsed. ((HBZSO Section 241.14) The Community Development Department réserves the right to revoke Administrative Permit No. 16- 001. pursuant to a public hearing for revocation, if any violation of the conditions of approval, Huntington Beach Zoning and Subdivision Ordinance or Municipal Code occurs. (HBZSO Section 241.16.D) The project shall comply with all applicable requirements of the Municipal Code, Community Development Department and Fire Department, as well as applicable local, State and Federal Fire Codes, Ordinances, and standards, except as noted herein. (City Charter, Article V) Construction shall be limited to Monday — Saturday 7:00 AM to 8:00 PM. Construction shall be prohibited Sundays and Federal holidays. (HBMC 8.40.090) All landscaping shall be maintained in a neat and clean manner, and in conformance with the HBZSO. Prior to removing or replacing any landscaped areas, check with the Community Development Department and Public Works for Code requirements. (HBZSO Section 232.04) /. J -1 L59 @ ¢5~:(“3‘.\/ED FEB Q9 2015 apt. o1Plannm9 HUNTINGTON BEAc§r—P““d‘“9 BUILDING DIVISION HUNTINGTON BEACH DATE: PROJECT NAME: PROJECT IMPLEMENTATION CODE REQUIREMENTS February 9, 2016 Blasingame Residence PLANNING APPLICATION NO. ENTITLEMENTS: DATE OF PLANS: PROJECT LOCATION: PLAN REVIEWER: TELEPHONEIE-MAIL: PROJECT DESCRIPTION: PLANNING APPLICATION NO. 2016-20 AP NO. 2016-01 January 19, 2016 16381 South Pacific Avenue, 90742 (north of 25"‘ St., south of Anderson St. — Sunset Beach) Khoa Duong, P.E (714) 872-6123/ khoa@csgengr.com To permit the demolition of an existing two—story single family dwelling unit with an attached garage and to construct a new three- story 3,915 sq. ft. single family dwelling unit with a 600 sq. ft. three car garage, with an overall maximum height of 35 ft. The following is a list of code requirements deemed applicable to the proposed project based on plans stated above. The list is intended to assist the applicant by identifying requirements which must be satisfied during the various stages of project permitting and implementation. A list of conditions of approval adopted by the Zoning Administrator in conjunction with the requested entitlement(s), if any, will also be provided upon final project approval. If you have any questions regarding these requirements, please contact the Plan Reviewer. I. REQUIREMENT: 1. 2. Development Impact Fees will be required for new construction. Submit separate plans for all disciplines; Building 3 sets, MEP 2 sets each. Landscape plan is a separate submittal for irrigation and plants only. No accessory structures or flat work will be reviewed on the landscape plans. All site work for accessibility will be reviewed and inspected based on the approved architectural plans. All accessory and minor accessory structures including site MEP will be on separate permits. II. CODE REQUIREMENTS BASED ON PLANS & DRAWINGS SUBMITTED: 1.Project shall comply with the current state building codes adopted by the city at the time of permit application submittal. Currently they are 2013 California Building Code (CBC), 2013 California Residential Code (CRC), 2013 California Mechanical Code, 2013 California Plumbing Code, 2013 California Electricar Code, 2013 California Energy Code, 2013 California Green Building Standards G ‘ 1 ;,-’ J P.0‘.0’.“.°°$9 13. 14. 15. Page 2 of 2 Code, and the Huntington Beach Municipal Code (HBMC). Compliance to all applicable state and local codes is required prior to issuance of building permit. Fire sprinkler system is required for all construction. Please specify on Project Data. Provide complete Roof plan showing: o Show the set back between roof projection and property line. 0 Length of eave projections. o Elevation plans - Show the set back between roof projection/projection and property line. Eave projections must comply with Table R302.1. Exterior walls must comply with Table R302.1. Check the required light, ventilation and egress window. With one exit serving the third floor, please check the distance of travel. Patio/Deck cannot construct on the other side of property line. Please clarify! Plans and calculations must be stamped and wet signed by architect/civil engineer licensed by State of California. . Energy calculations and structural calculations are required. 11. 12. Soil report is required. Review and provide compliance with Title 17 of the City of Huntington Beach Municipal Code, Building and Construction. This document can be found online on the city's website. For projects that will include multiple licensed professions in multiple disciplines, i.e. Architect and professional engineers for specific disciplines, a Design Professional in Responsible Charge will be requested per the 2013 CBC, Section 1073.4. In addition to all of the code requirements of the 2013 California Green Building Standards Code, specifically address Construction Waste Management per Sections 4.408.2, 4.408.3, 4.408.4, 5.408.1.1, 5408.12, and 5.408.1.3 and Building Maintenance and Operation, Section 5.410. Prior to the issuance of a building permit the permitee will be required to describe how they will comply with the sections described above. Prior to Building Final Approval, the city will require a Waste Diversion Report per Sections 4.408.5 and 5.408.1.4. The City of Huntington Beach has adopted the 2013 California Green Building Standards Code Appendices for Electric Vehicle Charging. This adopted Code may be found in the Huntington Beach Municipal Code under; Chapter 17.06.030 Residential Electric Vehicle (EV) Charging and 17.06.04O Non-Residential Electrical Vehicle (EV) Charging. III. COMMENTS: 1. 2. 3. Planning and Building Department encourage the use of pre-submittal building plan check meetings. Separate Building, Mechanical, Electrical and Plumbing Permits will be required for all exterior accessory elements of the project, including but not limited to: fireplaces, fountains, sculptures, light poles, walls and fences over 42" high, retaining walls over 2’ high, detached trellises/patio covers, gas piping, water service, backflow anti-siphon, electrical, meter pedestals/electrical panels, swimming pools, storage racks for industrial/commercial projects. It will be the design professional in charge, responsibility to coordinate and submit the documents for the work described above. Provide on all plan submittals for building, mechanical, electrical and plumbing permits, the Conditions of Approval and Code Requirements that are associated with the project through the entitlement process. If there is a WQMP, it is required to be attached to the plumbing plans for plan check. O J‘ HUNTINGTON BEACH FIRE DEPARTMENT . @ PROJECT IMPLEMENTATION CODE REQUIREMENTS HUNTINGTON BEACH ' DATE: FEBRUARY 1ST, 2016 R E L; PROJECT NAME: NEW SFR PLANNING APPLICATION: PLANNING APPLICATION NO. 2016-020 FEB 01 2015 ENTITLEMENTS: _ ADMINISTRATIVE PERMIT NO. 2016-O01 Dem of Planning & Building PROJECT LOCATION: 16381 s. PACIFIC AVE., SUNSET BEACH PLANNER: KIMO BURDEN, ASSISTANT PLANNER PLAN REVIEWER-FIRE: JAMES BROWN, FIRE PROTECTION ANALYST TELEPHONEIE-MAIL: (714) 374-5344/ jbrown@surfcity—hb.org PROJECT DESCRIPTION: TO CONSTRUCT A NEW THREE-STORY SINGLE FAMILY RESIDENCE WITHIN THE SUNSET BEACH AREA (APPROVAL IN CONCEPT TO THE COASTAL COMMISSION) T . The following is a list of code requirements deemed applicable to the proposed project based on plans received and dated JANUARY 19“, 2016. The list is intended to assist the applicant by identifying requirements which must be satisfied during the various stages of project permitting and implementation. A list of conditions of approval adopted by the Planning Commission in conjunction with the requested entitlement(s), if any, will also be provided upon final project approval. If you have any questions regarding these requirements, please contact the Plan Reviewer- Fire: JAMES BROWN, FIRE PROTECTION ANALYST. Automatic Fire Sprinklers are required. NFPA13d Automatic fire sprinkler systems are required per the California Fire Code and California Residential Code for new single family homes. Separate plans (two sets) shalkphés ubmitted to the Fire Department for permits and approval. $3 For Fire Department approval, reference that a fire sprinkler system will be installed in compliance with the California Fire Code, NFPA 13d, and City Specification # 420 - Automatic Fire Sprinkler Systems in the building plan notes. (FD) NOTE: THE STRUCTURE IS THREE STORIES IN HEIGHT. AS SUCH, THE PUBLIC WORKS DEPARTMENT WILL REQUIRE A BACKFLOW DEVICE (DCDA) ON THE WATER SERVICE. IT MUST BE DESIGNED AND CALCULATED INTO THE FIRE SPRINKLER SYSTEM. Residential (SFD) Address Numbers shall be installed to comply with City Specification #428, Premise Identification. Number sets are required on front of the structure in a contrasting color Page 2 of 2 with the background and shall be a minimum of four inches (4”) high with one and one half inch (W) brush stroke. For Fire Department approval, reference compliance with City Specification #428, Premise Identification in the plan notesand portray the address location on the building. (FD) THE FOLLOWING SHALL BE MAINTAINED DURING CONSTRUCTION: afr ' Fi're/’Ermergen'cy Acc'ess And Site Safety shall be maintained during project construction phases in complianbe with CFC Chapter 33, Fire Safety During Construction And Demolition. (FD) OTHER: a. Discovery of additional soil contamination or underground pipelines, etc., must be reported to the Fire Department immediately and the approved work plan modified accordingly in compliance with City Specification #431-92 Soil Clean-Up Standards. (FD) b. Outside City Consultants The Fire Department review of this project and subsequent plans may require the use of City consultants. The Huntington Beach City Council approved fee schedule allows the Fire Department to recover consultant fees from the applicant, developer or other responsible party. (FD) Fire Department City Specifications may be obtained at: Huntington Beach Fire Department Administrative Office City Hall 2000 Main Street, 5‘“ floor Huntington Beach, CA 92648 or through the City’s website at htt :llwww.huntin tonbeachca. ovl overnmentlde artmentsIFireIfire revention code enforce mentlfire de t ci s ecifications.cfm If you have any questions, please contact the Fire Prevention Division at (714) 536-5411. CIT-Y or HUNTINGTON BEACH PUBLIC WORKS INTERDVEPARTMENTAIL COIVKMUNICATION PROJECT IMPLEMENTATION CODE REQUIREMENTS DATE: FEBRUARY 11, 2016 REM.‘ ,.._D PROJECT NAME: VON BLASINGAME RESIDENCE - ENTITLEMENTS: AP 16-O1 % FEB 1 1 2015 PLNG APPLICATION NO: 2016-0020 V U:‘p§l:3i'-dri'I;Z1r‘wIIrn9 DATE OF PLANS: JANUARY 19, 2016 PROJECT LOCATION: 16361 SOUTH PACIFIC PROJECT PLANNER: KIMO BURDEN, ASSISTANT PLANNER PLAN REVIEWER: BOB MILANI, SENIOR CIVIL ENGINEER TELEPHONE/E-MAIL: 714-374-1735 / BOBMILANI SURFCITY-HB.ORG PROJECTDESCRIPTION: REQUEST TO CONSTRUCT A NEW SINGLE FAMILY RESIDENCE WITHIN SUNSE-T BEACH The following is a list of code requirements deemed applicable to the proposed project based on plans as stated above. The items below are to meet the City of Huntington Beach’s Municipal Code (HBMC), Zoning and Subdivision Ordinance (ZSO), Department of Public Works‘ Standard Plans (Civil, Water and Landscaping) and the American Public Works Association (APWA) .................a.-—.m 'Standards Specifications for Public Works Construction (Green Book), the Orange County Drainage Area management Plan (DAMP), and the City Arboricultural and Landscape Standards and Specifications. The list is intended to assist the applicant by identifying requirements which shall be satisfied during the various stages of project permitting, implementation and construction. If you have any questions regarding these requirements, please Contact the Plan Reviewer or Project Planner. . THE FOLLOWING DEVELOPMENT REQUIREMENTS SHALL BE COMPLETED PRIOR TO ISSUANCE OF A GRADING PERMIT: 1. A Precise Grading Plan, prepared by a Licensed Civil Engineer, shall be submitted to the Public Works Department for review and approval. (MC 17.05/Z-SO 230.84) The plans shall comply with Public Works plan preparation guidelines and include the following improvements on the plan: ' a. The existing sewer lateral may potentially be utilized if it is of adequate size, conforms to current Public Works Standards and is determined to be in serviceable condition by submitting a video of the lateral. If the sewer is determined to be inadequate, a new sewer lateral shall be installed, connecting to the main in the alley, per Public Works Standards. (ZSO 230.84) b. A new domestic water service and meter shall be installed per Water Division Standards, and sized to meet the minimum requirements set by the California 2. 3. 4. 5. Page 2 of 3 Plumbing Code (CPC) if residential add: and Uniform Fire Code (UFC). (ZSO 230.84) (MC 14.08.020) c. The irrigation water service may be combined with the domestic water service. (ZSO 230.84) M d. Separate backflow protection devices shall be installed per Water Division Standards for domestic, irrigation and fire water services, and shall be screened from view. (Resolution 5921 and State of California Administrative Code, Title 17) 'e. The existing domestic water service and meter, if not being used shall be abandoned per Water Division Standards. (ZSO 230.84) - A detailed soils and geological/seismic analysis shall be prepared by a registered engineer. This analysis shall include on~site soil sampling and laboratory testing of materials to provide detailed recommendations for grading, over excavation, engineered fill, dewatering, settlement, protection of adjacent structures, chemical and fill properties, liquefaction, retaining walls, streets, and utilities. (MC 17.05150) The applicanfs gradinglerosion control plan shall abide by the. provisions of AQMD's Ruie 403 as related to fugitive dust control. (AQMD Rule 403) The name and phone number of an on—site field supervisor hired by the developer shall be submitted to the Planning and Public Works Departments. In addition, dearly visible signs shall be posted on the perimeter of the site every 250 feet indicating who shall be contacted for information regarding this development and any construction/grading—related concerns. This contact person shall be available immediately ‘to address any concerns or issues raised by adjacent property owners during the construction activity. He/She will be responsible for ensuring compliance with the conditions herein, specifically, grading activities, truck routes, construction hours, noise, etc. Signs shall include the applicant's contact number, regarding grading and construction activities, and “1—800-CUTSMOG” in the event there are concerns regarding fugitive dust and compliance with AQMD Rule No. 403. - The applicant shall notify all property owners and tenants within 300 feet of the perimeter of the property of a tentative grading schedule at least 30 days prior to such grading. THE FOLLOWING DEVELOPMENT REQUIREMENTS SHALL BE COMPLIED WITH DURING 6. 7. 8. 9. GRADING OPERATIONS: An Encroachment Permit is required for all work within the City’s right—of-way. 12.38010/MC 14.36.030) - The developer shall coordinate the development of a truck haul route with the Department of Public Works if the import or export of material in excessof 5000 cubic yards is required. This plan shall include the approximate number of truck trips and the proposed truck haul routes. It shall specify the hours in which transport activities can occur and methods to mitigate construction—related impacts to adjacent residents. These plans must be submitted for approval to the Department of Public Works. (MC 17.05210) Water trucks will be utilized on the site and shall be available to be used throughout the day during site grading to keep the soil damp enough to prevent dust being raised by the operations. (California Stormwater BMP Handbook, Construction Wind Erosion WE—1) (MC AH haul trucks shall arrive at the site no earlier than 8:00 a.m. or leave the site no later than 5:00 p.m., and shall be limited to Monday through Friday only. (MC 17.05) L . Q I 'v I iII I 1 I 10. 11. 12. 13. 14. 15. 16. Page 3 of 3 Wet down the areasthat are to be graded or that is being graded, in the late morning and after work is completed for the day. (WE—1/MC 17.05) The construction disturbance area shall be kept as small as possible. (California Stormwater BMP Handbook, Construction Erosion Control EC—1) (DAMP) [All haul trucks shall be covered or have water applied to the exposed surface prior to leaving the site to prevent dust from impacting the surrounding areas. (DAMP) Prior to leaving the site, all haul trucks shall be washed off on-site on a gravel surface to prevent dirt and dust from leaving the site and impacting public streets. (DAMP) Comply with appropriate sections of AQMD Rule 403, particularly to minimize fugitive dust and noise to surrounding areas. (AQMD Rule 403) Wind barriers shall be installed along the perimeter of the site. (DAMP) All construction matérials, wastes, grading or demolition debris and stockpiles of- soils, aggregates, soil amendments, etc. shall‘ be. properly covered, stored and secured-to ; prevent transport into surface or ground waters by.wind, rain, tracking, tidal erosion or dispersion. (DAMP) THE FOLLOWING DEVELOPMENT REQUIREMENTS SHALL BE COMPLETED PRIOR TO 17. 18. ISSUANCE OF A BUILDING PERMIT: - A Precise Grading Permit shall be issued. (MC 17.05) The applicable Orange County Sanitation District Capital Facility Capacity Charge shall be paid to the City Department of Public Works. (Ordinance OCSD-40) ' THE FOLLOWING DEVELOPMENT REQUIREMENTS SHALL BE COMPLETED PRIOR TO 19. 20. -21. FINAL INSPECTION OR OCCUPANCY: Complete all improvements as shown on the approved grading plans. (MC_f17.05) All new utilities shall be undergrounded. (MC 17.64) All applicable Public Works feesshall be paid at the current rate unless otherwise stated, per the Public Works Fee Schedule adopted by the City Counc_iI and available on the city web site at htt ://www.surfcit -hb.or /files/users/ ublic works/fee schedule. df. (ZSO 240.06/ZSO 250.16) .4’ ‘ PLANNING DIVISION be M,4,91420 DEVELOPMENT REVIEW REQUEST Pt orp,a, /6‘ II I" 0' - U//d/n TO: Josh McDonald, Public Works Steve Eros, Fire Mark Carnahan, Building Dave Dominguez, Community Services FROM: Kirpo Burden Ext: 5438 DATE: JANUARY 28, 2016 III PC El ZA El DRB LZI STAFF PETITION(S): Planning Application No. 2016-20: Administrative Permit No. 2016-01 REQUEST(S): To permit the demolition of an existing two-story single family dwelling unit with an attached garage and to construct a new three-story 3,915 sq. ft. single family _dwelling unit with a 600 sq. ft. three car garage, with an overall maximum height of 35 ft. LOCATION: . 16381 South Pacific Avenue, 90742 (north of 25”‘ St., south of Anderson St. — Sunset Beach) V ZONE: Specific Plan No. 17 Coastal Zone (SP17-CZ) GENERAL PLAN: Sunset Beach EXISTING USE: existing SFR Please submit your concerns and recommended changes or conditions in writing on or before February 12, 2016. V (Use attachments or back side of sheet if necessary) V Rmmwv ‘nwlcn ‘ $ -rncnmmanqécf cm?» iormm V TF3 % In mrtne ma ad pact. RESPONSE BY: :D°Ve' ’D°‘'‘’‘’‘'‘’‘ “'92 r C°'"’“"'- S°"ViwSExtension 530°‘ Attachments: 1. Plans 2. Narrative