HomeMy WebLinkAbout1996-03-13I�
1
MINUTES
HUNTINGTON BEACH OFFICE OF THE ZONING ADMINISTRATOR
Room B-6 - Civic Center
2000 Main Street
Huntington Beach, California
`NEDNESDAY, MARCH 13, 1996 - 1:30 P.M.
ZONING ADMINISTRATOR: Herb Fauland
STAFF MEMBERS: Jane Madera, Robert Franklin, Mary Beth Broeren, Lisa
Koch
MINUTES: None
ORAL COMMUNICATION: None
ITEM 1: CONDITIONAL USE PERMIT NO. 95-31(R)
COASTAL DEVELOPMENT PERMIT NO. 95-5(R)
Applicant: Freddie Leonard
Request: To permit a revision to a previously approved remodel and addition at an
existing single family residence. The revised project consists of a 388 square
foot second floor deck, a 1,511 square foot second floor addition and a 499
square foot third floor deck.
Location: 3342 Bounty (Admiralty Island, Huntington Harbor)
Jane Madera, project planner, stated that this was a request to permit a revision to a previously
approved remodel and addition at an existing single family residence. The revised project consists
of a 388 square foot second floor deck, a 1,511 square foot second floor addition and a 499
square foot third floor deck. Ms. Madera stated that all of the Code requirements are met, such
as setbacks, site coverage and building height. Staff recommended that the third story deck be
revised so that it is set back a minimum of five (5) feet from the second story facade in order to
protect the privacy of adjacent neighbors. It was noted that one letter had been received from the
Huntington Harbor Homeowners Association stating that a representative could not attend the
hearing. The association requested a continuance of this application because their architectural
committee had not reviewed and approved the revised plans. Ms. Madera stated that association
approval is not a requirement of the City. Staff recommended approval of this request with
standard conditions.
March 13, 1996 Zoning Administrator Meeting Minutes
Page 2
THE PUBLIC HEARING WAS OPENED.
THERE WERE NO PERSONS PRESENT TO SPEAK FOR OR AGAINST THE
REQUEST AND THE PUBLIC HEARING WAS CLOSED.
CONDITIONAL USE PERMIT NO. 95-31(R)/COASTAL DEVELOPMENT PERMIT
NO. 95-5(R) WAS CONDITIONALLY APPROVED BY THE ZONING
ADMINISTRATOR. HE STATED THAT THE ACTION TAKEN BY THE ZONING
ADMINISTRATOR CAN BE APPEALED TO THE PLANNING COMMISSION
WITHIN TEN (10) CALENDAR DAYS.
FINDINGS FOR APPROVAL - COASTAL DEVELOPMENT PERMIT NO. 95-5(R):
The request to permit the remodel, addition of 388 square feet of second floor deck, 1,511
square feet of new second floor, and 499 square foot third story deck addition to an
existing one-story single family residence conforms with the plans, policies, requirements
and standards of the Coastal Element of the General Plan. The proposed second and third
story additions will not impact public views or access as there are no public views or
access to coastal amenities and will be none after project completion.
2. Coastal Development Permit No. 95-5(R) is consistent with the CZ suffix zoning
requirements, the Rl Zoning District, as well as other provisions of the Huntington Beach
Local Coastal Program applicable to the property. The proposed development will
conform with all applicable City codes and is compatible with other single family homes in
the neighborhood.
At the time of occupancy, the proposed remodel, second and third story addition to an
existing one-story single family residence will be provided with infrastructure in a manner
that is consistent with the Coastal Element of the General Plan. All infrastructure
currently exist to the site.
4. The proposed remodel, second and third story addition to an existing one-story single
family residence conforms with the public access and public recreation policies of Chapter
3 of the California Coastal Act. The second and third story additions will have no impact
on public access to coastal areas and will have no effect on public recreation policies as
the use of the home will remain single family residential.
]FINDINGS FOR APPROVAL - CONDITIONAL USE PERMIT NO. 95-31(R):
1. Conditional Use Permit No. 95-31(R) for the establishment, maintenance and operation of
the 499 square foot third story deck in conjunction with a remodel and second story
addition will not be detrimental to the general welfare of persons residing or working in
the vicinity nor detrimental to the value of the property and improvements in the
neighborhood. With the conditions of approval imposed, the third story deck meets all
design and development standards of the Local Coastal Program to prevent intrusion of
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 3
privacy of adjacent neighbors. The deck is centered in the middle of the home to prevent
views directly into adjacent properties.
2. The granting of Conditional Use Permit No. 95-31(R) will not adversely affect the General
Plan of the City of Huntington Beach. The third story deck in conjunction with the
remodel and second story addition is consistent with the goals and objectives of the Low
Density Residential land use designation of the General Plan.
3. The proposed use will comply with the provisions of the base district and other applicable
provisions in Titles 20-25 and any. specific condition required for the proposed use in the
district in which it would be located.
SPECIAL CONDITIONS OF APPROVAL - COASTAL DEVELOPMENT PERMIT NO.
95-5(R) / CONDITIONAL USE PERMIT NO.95-31(R):
The site plan, floor plans, and elevations received and dated January 17, 1996, shall be the
conceptually approved layout with the following modifications:
a. The proposed side yard setback to the new second story addition shall be depicted on
site plan (minimum five [5] foot setback required).
b. The proposed rear yard setback to the second floor addition shall be depicted on site
plan (minimum five [5] foot setback required).
c. Maximum 25 feet to second story plate height and overall total height of structure
shall be depicted on elevations.
d. The third level deck shall be setback a minimum of five (5) feet on all sides from the
second story facade.
2. One (1) set of revised site plans, floor plans, and elevations shall be submitted depicting
the modifications described above prior to submittal for building permits.
3. Obtain permits for and install a backflow device.
4. All proposed cantilevered deck, dock, and ramp improvements shall require separate
permits for the improvements located within the public waterways.
5. All building spoils, such as unusable lumber, wire, pipe, and other surplus or unusable
material, shall be disposed of at an off -site facility equipped to handle them.
6. Low -volume heads shall be used on all spigots and water faucets.
7. The Zoning Administrator shall be notified in writing if any changes in building height,
floor area, setbacks, building elevations or open space are proposed as a result of the plan
check process. Building permits shall not be issued until the Zoning Administrator has
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 4
reviewed and approved the proposed changes. The Zoning Administrator reserves the
right to require that an amendment to the original entitlement be processed if the proposed
changes are of a substantial nature.
8. Conditions of approval shall be printed verbatim on the cover sheet of all working drawing
sets submitted for plancheck.
INFORMATION ON SPECIFIC CODE REQUIREMENTS:
The development shall comply with all applicable provisions of the Ordinance Code,
Building Division, and Fire Department.
2. The applicant shall meet all applicable local, State, and Federal Fire Codes, Ordinances,
and standards.
3. The applicant shall pay all applicable Public Works fees.
4. An encroachment permit shall be required for any work within the public right-of-way.
5. The Zoning Administrator reserves the right to revoke Coastal Development Permit No.
95-5(R) / Conditional Use Permit No. 95-31(R) if any violation of these conditions of the
Huntington Beach Ordinance Code occurs.
ITEM 2: CONDITIONAL USE PERMIT NO.96-2
TENTATIVE PARCEL MAP NO. 95-183
Applicant: Warren C. Pitt
Request: To construct a 3,930 square foot industrial building for automotive repair with
four (4) compact parking spaces and consolidate two (2) lots into one (1)
parcel.
Location: 17122 Gothard Street (east side of Gothard Street, approximately 250 feet
north of Cedar Avenue)
Robert Franklin, project planner, stated that this was a request to construct a 3,930 square foot
industrial building for automotive repair with four (4) compact parking spaces and consolidate
two (2) lots into one (1) parcel. Mr. Franklin stated that the building will have a single access
point off of Gothard Street with a security gate behind the setback. It was noted that there will be
adequate parking on site. Comments from other departments consisted of standard conditions.
Public Works stated that the security gate must be open during business hours to prevent stacking
on Gothard Street. In addition, a grading plan and Landscape Construction Set must be
submitted to Public Works for review and approval. The Fire Department required that one (1)
on -site fire hydrant be provided, as well as an automatic fire sprinkler system. It was noted that
all vehicles, vehicle parts, equipment and trailers must be stored inside the building and that all
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 5
repair work must be conducted within the building. Mr. Franklin stated that elevations were
subject to approval by the Design Review Board. Staff recommended approval of the request.
THE PUBLIC HEARING WAS OPENED.
Lee Gilstrand, adjacent property owner, questioned whether or not a new block wall or fence
would be constructed to partition his property from the proposed industrial building.
Warren Pitt, applicant, stated that there will be a complete block wall constructed to secure the
industrial building.
THERE WERE NO OTHER PERSONS PRESENT TO SPEAK FOR OR AGAINST THE
]REQUEST AND THE PUBLIC HEARING WAS CLOSED.
CONDITIONAL USE PERMIT NO. 96-2 / TENTATIVE PARCEL MAP NO. 95-183 WAS
CONDITIONALLY APPROVED BY THE ZONING ADMINISTRATOR. HE STATED
THAT THE ACTION TAKEN BY THE ZONING ADMINISTRATOR CAN BE
APPEALED TO THE PLANNING COMMISSION WITHIN TEN (10) CALENDAR
]DAYS.
]FINDINGS FOR APPROVAL - CONDITIONAL USE PERMIT NO.96-2:
1. Conditional Use Permit No. 96-2 a request to construct a 3,930 square foot building for
automotive repair will not be detrimental to the general welfare of persons residing or
working in the vicinity nor detrimental to the value of the property and improvements in
the neighborhood.
2. The granting of Conditional Use Permit No. 96-2 will not adversely affect the General
Plan of the City of Huntington Beach.
3. The proposed 3,930 square foot building for automotive repair will comply with the
provisions of the General Industrial District and other applicable provisions in Titles 20-
25.
SPECIAL CONDITIONS OF APPROVAL - CONDITIONAL USE PERMIT NO.96-2:
The site plan and floor plan received and dated January 12, 1996 shall be the conceptually
approved layout.
2. Prior to submittal for building permits, the following shall be completed:
a. Conditions of approval shall be printed verbatim on the cover sheet of all working
drawing sets submitted for plancheck.
b. Depict utility apparatuses, such as but not limited to backflow devices and Edison
transformers on the site plan. They shall be prohibited in the front yard and
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 6
1
exterior sideyards unless properly screened by approved landscaping or any other
method approved by the Community Development Director.
c. Submit three (3) copies of the site plan to the Planning Division for addressing
purposes.
Prior to issuance of building permits, the following plans and items shall be submitted
and/or completed by the applicant:
a. A grading plan shall be submitted to the Department of Public Works for review
and approval.
b. A Landscape Construction Set submitted to the Department of Public Works. The
landscape construction set shall include a landscape plan prepared and signed by a
State Licensed Landscape Architect which includes all proposed/existing plant
materials (location, type, size, quantity), irrigation plan, grading plan and approved
site plan, and copy of conditions of approval.
The landscape plan shall be in conformance with Chapter 232 of the Huntington
Beach Zoning and Subdivision Ordinance. The set must be complete and
approved by both Departments of Community Development and Public Works
prior to issuance of building permits.
c. Rooftop Mechanical Equipment Plan. Said plan shall indicate screening of all
rooftop mechanical equipment and shall delineate the type of material proposed to
screen said equipment.
d. Elevations shall be subject to approval by the Design Review Board.
e. Obtain proper City clearance to demolish the existing structures on the property.
f. Obtain a demolition permit for the existing structures from the Building Division.
4. Prior to final inspection:
a. Street improvement plans, prepared by a registered civil engineer, shall be
submitted to the Department of Public Works for review and approval.
b. All building spoils, such as unusable lumber, wire, pipe, and other surplus or
unusable material, shall be disposed of at an off -site facility equipped to handle
them.
c. Compliance with all conditions of approval specified herein shall be accomplished.
d. Installation of required landscaping and irrigation systems.
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 7
e. Construct new block wall along rear and side property lines as indicated on the site
plan.
f. Tentative Parcel Map No. 98-183 shall be approved by the City Council.
g. Remove and replace existing sidewalks and gutters per Public Works review and
approval.
h. Public water improvements shall conform to the Water Division's standards.
i. Provide street lights as required by Public Works.
5. Fire Department Requirements:
a. One on -site fire hydrant shall be provided at the location specified by the Fire
Department.
b. An automatic fire sprinkler system shall be approved and installed pursuant to Fire
Department regulations.
c. Service roads and fire lanes, as determined by the Fire Department, shall be posted
and marked.
d. Fire access lanes shall be maintained. If fire lane violations occur and the services
of the Fire Department are required, the applicant will be liable for expenses
incurred.
e. Address numbers shall be installed to comply with City Specification #428.
6. There shall be no outside storage of vehicles, vehicle parts, equipment or trailers.
7. All repair work shall be conducted wholly within the building.
8. If lighting is included in the parking lot, high-pressure sodium vapor lamps shall be used
for energy savings. All outside lighting shall be directed to prevent "spillage" onto
adjacent properties.
9. The Zoning Administrator shall be notified in writing if any changes in building height,
floor area, setbacks, building elevations or open space are proposed as a result of the plan
check process. Building permits shall not be issued until the Zoning Administrator has
reviewed and approved the proposed changes. The Zoning Administrator reserves the
right to require that an amendment to the original entitlement be processed if the proposed
changes are of a substantial nature.
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page S
]FINDINGS FOR APPROVAL - TENTATIVE PARCEL MAP NO. 95-183:
1. The proposed map is consistent with the General Plan and the General Industrial zoning
district.
2. The site is physically suitable for the type of development.
3. The design of the subdivision will not cause serious health problems or substantial
environmental damage.
4. The design of the subdivision will not conflict with easements, acquired by the public at
large, for access.
SPECIAL CONDITIONS OF APPROVAL - TENTATIVE PARCEL MAP NO. 95-183:
A. TO BE COMPLETED PRIOR TO USE OR OCCUPANCY OF SAID PARCELS(S)
FOR ANY PURPOSE
1. Tentative Parcel Map No. 95-183 received by the Department of Community
Development on March 10, 1996 shall be the approved layout.
2. The following conditions are required to be completed prior to recordation of the
final map:
a. All vehicular access rights to Gothard Street shall be released and relinquished to
the City of Huntington Beach except at locations approved by the Zoning
Administrator.
b. The surveyor/engineer preparing the map shall tie the boundary of the map into
the Horizontal Control System established by the County Surveyor in a manner
described in Sections 7-9-330 and 7-9-337 of the Orange County Subdivision
Code and Orange County Subdivision Manual, Subarticle 18.
The surveyor/engineer preparing the map shall submit to the County Surveyor a
digital -graphics file of said map in a manner described in Sections 7-9-330 and 7-
9-337 of the Orange County Subdivision Code and Orange County Subdivision
Manual, Subarticle 18.
]INFORMATION ON SPECIFIC CODE REQUIREMENTS:
1. The development shall comply with all applicable provisions of the Huntington Beach
Zoning and Subdivision Ordinance, Building Division, and Fire Department.
2. The applicant shall meet all applicable local, State, and Federal Fire Codes, Ordinances,
and standards.
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 9
3. The applicant shall obtain applicable permits from the South Coast Air Quality
Management District.
4. All applicable Public Works fees shall be paid.
5. Traffic Impact fees shall be paid at the time of issuance of a Certificate of Occupancy.
6. An encroachment permit shall be required for all work within the City right-of-way.
7. If applicable, the development shall meet all local and State regulations regarding
installation and operation of all underground storage tanks.
A detailed soils analysis shall be prepared by a registered Soils Engineer. This analysis
shall include on -site soil sampling and laboratory testing of materials to provide detailed
recommendations regarding grading, chemical and fill properties, foundations, retaining
walls, streets, and utilities.
9. All signs shall conform with the Huntington Beach Zoning.
10. Construction shall be limited to Monday through Saturday, 7:00 AM to 8:00 PM.
Construction shall be prohibited Sundays and federal holidays.
11. The Zoning Administrator reserves the right to revoke Conditional Use Permit No. 96-2
and Tentative Parcel Map No. 95-183 if any violation of these conditions of the
Huntington Beach Zoning and Subdivision Ordinance occurs.
ITEM 3: COASTAL DEVELOPMENT PERMIT NO. 96-2
Applicant: Dr. Leon Lis / Frank Mirjahangir
Request: To permit the remodel of an existing single family dwelling, including the
addition of 728 square feet on the second floor and 57 square feet on the first
floor; enclosure of a 154 square foot entry area and widening of the driveway
and approach.
Location: 16767 Bolero (Davenport Island, Huntington Harbor)
Mary Beth Broeren, project planner, stated that this was a request to permit the remodel of an
existing single family dwelling, including the addition of 728 square feet on the second floor and
57 square feet on the first floor; enclosure of a 154 square foot entry area and widening of the
driveway and approach. Public Works reviewed the request to expand the driveway and
approach and the only recommended condition was that the applicant submit for an encroachment
permit for work that will affect the public right-of-way. Ms. Broeren stated that standard
conditions of approval apply. It was noted that the project is compatible with the surrounding
area. There have been no phone calls or letters received from adjacent property owners. One
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 10
letter from the Huntington Harbor Homeowners Association was received in support of the
remodel. Staff recommended approval of the request.
THE PUBLIC HEARING WAS OPENED.
Frank Mirjahangir, co -applicant, was present and reiterated the fact that the Huntington Harbor
Homeowners Association was in support of his application.
THERE WERE NO OTHER PERSONS PRESENT TO SPEAK FOR OR AGAINST THE
]REQUEST AND THE PUBLIC HEARING WAS CLOSED.
COASTAL DEVELOPMENT PERMIT NO. 96-2 WAS CONDITIONALLY APPROVED
BY THE ZONING ADMINISTRATOR. HE STATED THAT THE ACTION TAKEN BY
THE ZONING ADMINISTRATOR CAN BE APPEALED TO THE PLANNING
COMMISSION WITHIN TEN (10) CALENDAR DAYS.
]FINDINGS FOR APPROVAL - COASTAL DEVELOPMENT PERMIT NO. 96-2:
1. The request for Coastal Development Permit No. 96-2 to permit the remodel and addition
to an existing two-story single family residence conforms with the plans, policies,
requirements and standards of the Coastal Element of the General Plan. The proposed
project will not impact public views or access as none exist in the vicinity.
2. Coastal Development Permit No. 96-2 is consistent with the CZ suffix zoning
requirements, the RI Zoning District, as well as other provisions of the Huntington Beach
Ordinance Code applicable to the property. The proposed development will conform with
all applicable City codes, including height, setbacks and parking.
3. At the time of occupancy, the proposed remodel and addition to an existing two-story
single family residence will be provided with infrastructure in a manner that is consistent
with the Coastal Element of the General Plan. All infrastructure currently exist to the site.
4. The proposed remodel and addition to an existing two story single family residence
conforms with the public access and public recreation policies of Chapter 3 of the
California Coastal Act. No public access or recreational opportunities will be affected by
the new construction.
SPECIAL CONDITIONS OF APPROVAL - COASTAL DEVELOPMENT PERMIT
NO.96-2:
The site plan, floor plans, and elevations received and dated February 2, 1996 shall be the
conceptually approved layout.
2. All proposed dock and ramp improvements shall require separate permits for the
improvements located within the public waterways.
(g:za:min:0313)
March 13, 1996 Zoning Administrator Meeting Minutes
Page 11
3. All proposed cantilevered deck improvements require separate permits for the
improvements.
4. All building spoils, such as unusable lumber, wire, pipe, and other surplus or unusable
material, shall be disposed of at an off -site facility equipped to handle them.
Natural gas shall be stubbed in at the locations of cooking facilities, water heaters, and
central heating units.
6. , Low -volume heads shall be used on all spigots and water faucets.
7. The Zoning Administrator shall be notified in writing if any changes in building height,
floor area, setbacks, building elevations or open space are proposed as a result of the plan
check process. Building permits shall not be issued until the Zoning Administrator has
reviewed and approved the proposed changes. The Zoning Administrator reserves the
right to require that an amendment to the original entitlement be processed if the proposed
changes are of a substantial nature.
]INFORMATION ON SPECIFIC CODE REQUIREMENTS:
1. The development shall comply with all applicable provisions of the Ordinance Code,
Building Division, and Fire Department.
2. The applicant shall meet all applicable local, State, and Federal Fire Codes, Ordinances,
and standards.
3. The applicant shall pay all applicable Public Works fees.
4. An encroachment permit shall be required for any work within the public right-of-way.
The applicant shall obtain the necessary permits from the South Coast Air Quality
Management District.
6. Landscaping shall comply with Section 9607 of the Huntington Beach Ordinance Code.
7. The Zoning Administrator reserves the right to revoke Coastal Development Permit No.
96-2 if any violation of these conditions of the Huntington Beach Ordinance Code occurs.
THE MEETING WAS ADJOURNED AT 2:00 P.M. BY THE ZONING
ADMINISTRATOR TO THE NEXT REGULARLY SCHEDULED MEETING OF THE
ZONING ADM ISTRATOR ON WEDNESDAY, MARCH 20, 1996.
�R
Herb Fauland, Zoning Administrator
(g:za:min:0313)