Loading...
HomeMy WebLinkAboutKENNEDY/JENKS CONSULTANTS, INC. - 1992-10-05sU ►>y Contracts Submittal to City Clerk's Office II���� ia.,,h• To: Connie Brockway, City Clerk o J 1. Name of Contractor: Kennedy/Jenks Consultants 2. Purpose of Contract: For Example: :ludh.Semces or II''Wer Qualm Iesnng Ihmtington Luke !Huntington Centieit'Prrk Consultants to Prepare a supplemental stutiv to the Sewer .1lcrster Plan. 3. Amount of Contract: 560,500 Copy of contract distributed to: The ORIGINAL insurance certificate/waiver sent to Risk Management ye5 Initiating Dept.� Cite Treasurer ✓ ORIGINAL bonds sent to l reasurer RECORDS DIIV.- Ckeek Cltv Clerk's Database A►r F.aisdvw Flit. O DONF. g1Attymisc/forms/city clerk contract transmittal doc 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 PROFESSIONAL SERVICES CONTRACT BETWEEN THE CITY OF HU TINGTON BEACH AND KEN'NEDY/JENKS CONSULTANTS TO PREPARE A SUPPLEMENTAL STUDY TO THE SEWER MASTER PLAN Table of Contents Scope of Services CityStaff Assistance................................................................................................2 Term; Time of Performance.....................................................................................2 Compensation...........................................................................................2 ExtraWork...............................................................................................................2 Methodof Payment..................................................................................................3 Disposition of Plans, Estimates and Other Documents...........................................3 HoldHarmless.........................................................................................................3 Professional Liability Insurance.............................................................................4 Certificate of Insurance............................................................................................5 Independent Contractor............................................................................................6 Termination of Agreement.................................................................I... I.................6 Assignment and Delegation......................................................................................6 Copyrights/Patents...................................................................................................7 City Employees and Officials..................................................................................7 Notices.........................................................................................7 Consent....................................................................................................................8 Modification.............................................................................................................8 SectionHeadings.....................................................................................................8 Interpretation of this Agreement .................... .................... ..:................ I .............. I ... 8 DuplicateOriginal....................................................................................................9 Immigration...............................................................................................................9 Legal Services Subcontracting Prohibited................................................................9 Attorney's Fees..........................................................................................................10 Survival ...................... GoverningLaw....................................................................... ...10 Entirety......................................................................................................................10 PROFESSIONAL SERVICES CONTRACT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDY/JENKS CONSULTANTS TO PREPARE A SUPPLEMENTAL STUDY TO THE SEWER MASTER PLAN THIS AGREEMENT ("Agreement") is made and entered into this v"A% day of M OLec.c)2004. by and between the City of Huntington Beach, a municipal corporation of the State of California. hereinafter referred to as "CITY, and KENINEDY/JENKS CONSULTANTS, a California corporation hereinafter referred to as "CONSULTANT." WHEREAS, CITY desires to engage the services of a consultant to prepare a supplemental study to the Sewer 'Master Plan; and Pursuant to documentation on file in the office of the City Clerk, the provisions of the Huntington Beach Municipal Code, Chapter 3.03, relating to procurement of professional service contracts have been complied with; and CONSULTANT has been selected to perform these services, 1\0W, THEREFORE, it is agreed by CITY and CONSULTANT as follows: 1. SCOPE OF SERVICES CONSULTANT shall provide all services as described in Exhibit "A," which is attached hereto and incorporated into this Agreemenf by this reference. These services shall sometimes hereinafter be referred to as the "PROJECT." CONSULTANT hereby designates Roger Null who shall represent it and be its sole contact and agent in all consultations with CITY during the performance of this Agreement. 04aereeikennedy' 6.04 1 2. CITY STAFF ASSISTANCE CITY shall assign a staff coordinator to work directly with CONSULTANT in the performance of this Agreement. 3. TERM; TIME OF PERFORMANCE Time is of the essence of this Agreement. The services of CONSULTANT are to commence as soon as practicable after the execution of this Agreement by CITY (the "Commencement Date"). This Agreement shall expire on April 30. 2005 unless sooner terminated as provided herein. All tasks specified in Exhibit "A" shall be completed no later than 365 days from the Commencement Date of this Agreement. These times may be extended with the written permission of CITY. The time for performance of the tasks identified in Exhibit "A" are generally to be shown in Exhibit "A." This schedule may be amended to benefit the PROJECT if mutually agreed to in writing by CITY and CONSULTANT. 4. COMPENSATIOI\ In consideration of the performance of the services described herein, CITY agrees to pay CONSULTANT, a fee, including all costs and expenses, not to exceed Sixty Thousand Five Hundred Dollars ($60,500.00). 5. EXTRA WORK In the event CITY requires additional services not included in Exhibit "A" or changes in the scope of services described in Exhibit "A," CONSULTANT will undertake such work only after receiving written authorization from CITY. Additional compensation for such extra work shall be allowed only if the prior written approval of CITY is obtained. 04 agree/kennedy/21W4 2 • G. METHOD OF PAYMENT CONSULTANT shall be paid pursuant to the terms of Exhibit "B." 7. DISPOSITION OF PLANS, ESTIMATES AND OTHER DOCUMENTS CONSULTANT agrees that title to all non-proprietary materials prepared hereunder, including, without limitation, all original drawings, designs, reports, both field and office notices, calculations, computer code, language, data or programs, maps, memoranda, letters and other documents, shall belong to CITY, and CONSULTANT shall turn these materials over to CITY upon expiration or termination of this Agreement or upon PROJECT completion, whichever shall occur first. These materials may be used by CITY as it sees fit, but any reuse for other than its intended use shall be at CITY'S sole risk. 8. HOLD HARMLESS CONSULTANT hereby agrees to protect, defend, indemnify and hold harmless CITY, its officers, elected or appointed officials, employees, agents and volunteers from and against any and all claims, damages, losses, expenses, judgments, demands and defense costs (including, without limitation, costs and fees of litigation of every nature or liability of any kind or nature) arising out of or in connection with CONSULTANT's (or CONSULTANT's subcontractors, if any) negligent performance of this Agreement or its failure to comply with any of its obligations contained in this Agreement by CONSULTANT, its officers, agents or employees except such loss or damage which was caused by the negligence or willful misconduct of CITY. CONSULTANT will conduct all defense at its sole cost and expense and CITY shall approve selection of CONSULTANT's counsel which shall not be unreasonably withheld. 04asreelkennedy/M104 3 This indemnity shall apply to all claims and liability regardless of whether any insurance policies are applicable. The policy limits do not act as limitation upon the amount of indemnification to be provided by CONSULTANT. 9. PROFESSIONAL LIABILITY INSURANCE CONSULTANT shall obtain and furnish to CITY a professional liability insurance policy covering the work performed by it hereunder. This policy shall provide coverage for CONSULTANT's professional liability in an amount not less than One Million Dollars ($1,000,000.00) per occurrence and in the aggregate. A claims -made policy shall be acceptable if the policy further provides that: A. The policy retroactive date coincides with or precedes the initiation of the scope of work (including subsequent policies purchased as renewals or replacements). B. CONSULTANT shall notify CITY of circumstances or incidents that might give rise to future claims. CONSULTANT will make every effort to maintain similar insurance during the required extended period of coverage following PROJECT completion. If insurance is terminated for any reason, CONSULTANT agrees to purchase an extended reporting provision of at least two (2) years to report claims arising from work performed in connection with this Agreement. 04agrce/kennedy/2/6/04 4 10. CERTIFICATE OF INSURANCE Prior to commencing performance of the work hereunder, CONSULTANT shall furnish to CITY a certificate of insurance subject to approval of the City Attorney evidencing the foregoing insurance coverage as required by this Agreement: the certificate IMIM1 G A. provide the name and policy number of each carrier and policy; B. shall state that the policy is currently in force; and C. shall promise that such policy shall not be suspended, voided or canceled by either party;, reduced in coverage or in limits except after thirty (30) days' prior written notice; however, ten (10) days' prior written notice in the event of cancellation for nonpayment of premium. CONSULTANT shall maintain the foregoing insurance coverage in force until the work under this Agreement is fully completed and accepted by CITY. The requirement for carrying the foregoing insurance coverage shall not derogate from CONSULTANT's defense, hold harmless and indemnification obligations as set forth in this Agreement. CITY or its representative shall at all times have the right to demand the original or a copy of the relevant portions of the policy of insurance. CONSULTANT shall pay, in a prompt and timely manner, the premiums on the insurance hereinabove required. 11. 'PNDEPENDENT CONTRACTOR CONSULTANT is, and shall be, acting at all times in the performance of this Agreement as an independent contractor herein and not as an employee of CITY. O;-agsee/kennedy/V6/04 5 CONSULTANT shall secure at its own cost and expense, and be responsible for any and all payment of all taxes, social security, state disability insurance compensation, unemployment compensation and other payroll deductions for CONSULTANT and its officers, agents and employees and all business licenses, if any, in connection with the PROJECT and/or the services to be performed hereunder. 12. TERMINATION OF AGREEMENT All work required hereunder shall be performed in a good and workmanlike manner. CITY may terminate CONSULTANT's services hereunder at any time with or without cause, and whether or not the PROJECT is fully complete. Any termination of this Agreement by CITY shall be made in writing, notice of which shall be delivered to CONSULTANT as provided herein. In the event of termination, all finished and unfinished documents, exhibits, report, and evidence shall, at the option of CITY, become its property and shall be promptly delivered to it by CONSULTANT. Should CITY modify any aforementioned documents, CITY shall remove CONSULTANT's name from the impacted documents. 13. ASSIGNMENT AND DELEGATION This Agreement is a personal service contract and the work hereunder shall not be assigned, delegated or subcontracted by CONSULTANT to any other person or entity without the prior express written consent of CITY. If an assignment, delegation or subcontract is approved, all approved assignees, delegates and subconsultants must satisfy the insurance requirements as set forth in Sections 9 and 10 hereinabove. 04agree/kennedy/2W04 6 14. COPYRIGHTSIPATENTS CITY shall own all rights to any patent or copyright on any work, item or material produced as a result of this Agreement. 15, CITY EMPLOYEES AND OFFICIALS CONSULTANT shall employ no CITY official nor any regular CITY employee in the work performed pursuant to this Agreement. No officer or employee of CITY shall have any financial interest in this Agreement in violation of the applicable provisions of the California Government Code. 16. NOTICES Any notices, certificates, or other communications hereunder shall be given either by personal delivery to CONSULTANT's agent (as designated in Section I hereinabove) or to CITY as the situation shall warrant. or by enclosing the same in a sealed envelope, postage prepaid, and depositing the same in the United States Postal Service, to the addresses specified below. CITY and CONSULTANT may designate different addresses to which subsequent notices, certificates or other communications will be sent by notifying the other party via personal delivery, a reputable overnight carrier or U. S. certified mail -return receipt requested: TO CITY: City of Huntington Beach ATTN: Todd Broussard 2000 Main Street Huntington Beach, CA 92648 04agrcu'kenned%1.2:'6 04 7 TO CONSULTANT: Roger Null Kennedy/Jenks Consultants 2151 Michelson Drive, Suite 200 Irvine, CA 92612-1311 • • 17. CONSENT When CITY's consent/approval is required under this Agreement, its consent/approval for one transaction or event shall not be deemed to be a consentlapproval to any subsequent occurrence of the same or any other transaction or event. 18. MODIFICATION No waiver or modification of any language in this Agreement shall be valid unless in writing and duly executed by both parties. 19. SECTIO>\ HEADINGS The titles, captions, section, paragraph and subject headings, and descriptive phrases at the beginning of the various sections in this Agreement are merely descriptive and are incl- .ded solely for convenience of reference only and are not representative of matt--;--. included or excluded from such provisions, and do not interpret, define. limit or describe, or construe the intent of the parties or affect the construction or interpretation of any provision of this Agreement. 20, INTERFRETATIONT OF THIS AGREEMENT The Ianguage of all parts of this Agreement shall in all cases be construed as a whole, according to its fair meaning, and not strictly for or against any of the parties. If any provision of this Agreement is held by an arbitrator or court of competent jurisdiction to be unenforceable, void, illegal or invalid, such holding shall not invalidate or affect the remaining covenants and provisions of this Agreement. No covenant or provision shall be deemed dependent upon any other unless so expressly provided here. As used in this Agreement, the masculine or neuter gender and singular or plural number shall be deemed to include the other whenever the context so indicates or requires. 04aeree.`kenned%--2r'6 01 8 • Nothing contained herein shall be construed so as to require the commission of any act contrary to law, and wherever there is any conflict between any provision contained herein and any present or future statute, law, ordinance or regulation contrary to which the parties have no right to contract, then the latter shall prevail, and the provision of this Agreement which is hereby affected shall be curtailed and limited only to the extent necessary to bring it within the requirements of the law. 21. DUPLICATE ORIGINAL The original of this Agreement and one or more copies hereto have been prepared and signed in counterparts as duplicate originals, each of which so executed shall, irrespective of the date of its execution and delivery, be deemed an original. Each duplicate original shall be deemed an original instrument as against any party who has signed it. 22. IMMIGRATION CONSULTANT shall be responsible for full compliance with the immigration and naturalization laws of the United States and shall, in particular, comply with the provisions of the United States Code regarding employment verification. 23. LEGAL SERVICES SUBCONTRACTING PROHIBITED CONSULTANT and CITY agree that CITY is not liable for payment of any subcontractor work involving legal services, and that such legal services are expressly outside the scope of services contemplated hereunder. CONSULTANT understands that pursuant to Huntington Beach City Charter Section 309, the City Attorney is the exclusive legal counsel for CITY; and CITY shall not be liable for payment of any legal services expenses incurred by CONSULTANT. 04agrec:'kenned}-2 6/04 9 24. ATTORNEY'S FEES In the event suit is brought by either party to construe, interpret and/or enforce the terms and/or provisions of this Agreement or to secure the performance hereof, each party shall bear its own attorney's fees, such that the prevailing party shall not be entitled to recover its attorney's fees from the non -prevailing party. 25. SURVIVAL Terms and conditions of this Agreement, which by their sense and context survive the expiration or termination of this Agreement, shall so survive. 26. GOVERNING LAW This Agreement shall be governed and construed in accordance with the laws of the State of California. 27. ENTIRETY The parties acknowledge and agree that they are entering into this Agreement freely and voluntarily following extensive arm's length negotiation, and that each has had the opportunity to consult with legal counsel prior to executing this Agreement. The parties also acknowledge and agree that no representations, inducements, promises, agreements or warranties, oral or otherwise. have been made by that party or anyone acting on that party's behalf, which are not embodied in this Agreement, and that that party has not executed this Agreement in reliance on any representation, inducement, promise. agreement, warranty, fact or circumstance not expressly set forth in this Agreement. This Agreement, and the attached exhibits, contain the entire agreement between the parties respecting the subject matter of this Agreement, and supercede all prior 04agrcc/kcnnedp/216iO4 10 understandings and agreements whether oral or in writing between the parties respecting the subject matter hereof. N WITNESS WHEREOF, the parties hereto have caused this Agreement to be executed by and through their authorized offices the day, month and year first above v&Titten. KENNEDY/JENKS CONSULTANTS (_ L print name ITS: (circle one) ChairmanlPresidcn ice President Ali D Bv: �2Z print name ITS: (circle one S�hief Financial Officer/Asst. Secretary - Treasurer 04agree/kennedy/216,'04 I i CITY OF HLNTNGTON BEACH, a municipal corporation of the State of CalifornLa.-- /J Director of /�c'6Xc. GJpr y � (Pursuant To HBAIC §3. 03.100) APPOVED AS TO FORM: CJ r ^C City At ey . REVIEWED AND APPROVED: sty Administrator (only for contracts S50, 000.00 and over) 16 �x141ZIT "W r Kennedy/Jenks Consultants Engineers & Sciendsts 2151 Michelson Drive, Suite 100 Irvine, California 92612-1311 949-261-1577 949-261-2134 (Fax) 18 December 2003 Mr. Todd Broussard, P.E. Engineering Division, Public Works Department City of Huntington Beach, City Hall 2000 Main Street Huntington Beach, Califomia 92648 Subject: Request for Proposal - Sewer Master Plan Additional Hydraulic Evaluations and Financial Services Dear Mr. Broussard: In accordance with our discussions, Kennedy/Jenks Consultants is pleased to present this proposal for additional services related to hydraulic and financial evaluations of the City's sewer system. As the consultant for the City's recent Sewer Master Plan, the additional evaluations can be readily integrated. The associated scope of work, project schedule, and engineering budget are provided in the following. SCOPE OF WORK Task 1 - Perform Hydraulic Evaluations of Storm Diversion Facilities 1.1 Evaluate the hydraulic implications of including dry weather flows from each of the 15 (9 existing and 6 future) storm water diversion facilities on the City's sewer system. Extract additional sewer pipeline data as necessary to extend the sewer model to each of the identified diversion facilities. Integrate the City provided measured and estimated flows as un-peaked point loads on the existing and future sewer system models to asses the hydraulic implications of continuing the use of these facilities. Meet with the City to discuss the hydraulic modeling findings. 1.2 Based on the findings of Task 1.1 and subsequent direction from City staff, perform a localized field flow study for up to 15 sites to assess the current hydraulic flow conditions downstream of each facility. The localized field study will be based on a data obtained during a 7-day dry weather field flow -monitoring program of the downstream sewer pipeline. The data will be correlated with the diversion facility operation for the existing 9 sites. 1.3 Based on the findings of the above analysis, review the need for a potential modification to the City's design criteria to provide adequate allowance for this additional sewage flow. 1.4 Prepare a letter report of findings to document the findings and recommendations of the previous subtasks. Task 2 — Perform an Incremental Sewer Cost Study In this task, the Consultant will support the City in the performance of a sewer cost study to assess the incremental rate impact of the O&M costs for the identified diversion facilities and to review and develop a cost recovery strategy for the harbor sewer pump out facilities. The cost recovery program shall consider integrating the cost in the existing maintenance fee, developing a surcharge rate, and/or the use of an annual dock/sticker fee. These services are described in the following subtasks. 2.1 Diversion Facility O&M Cost Recovery Program. In this subtask, the Consultant will integrate the City's costs associated with the diversion facilities into the existing revenue requirements of the sewer maintenance fee. The costs to be identified and integrated shall include the City's 0&M costs, applicable permit fees, outside agency pass -through wastewater treatment costs, and other costs related to the management and administration of the diversion program. Once the un-funded costs have been identified, an incremental impact on the sewer maintenance fee will be derived. The incremental impact will be derived by correlating the annualized cost of service with the estimated revenues generated from the current and projected maintenance fee. The un-funded costs will be unitized on a per account or EDU basis and proposed annual maintenance fee adjustments will be derived. 2.2 Harbor Area Sewer Pump Out Cost Recovery Program. In a similar manner to the conduct of services in Task 2.1, in this subtask the Consultant will integrate the City's costs associated with the local harbor sewer pump out facilities into the existing revenue requirements of the sewer maintenance fee. Upon completion of the development of program -related costs, we will develop a cost recovery strategy for implementation by the City. Up to three cost recovery alternatives will be developed. These include integrating the cost in the existing maintenance fee, developing a surcharge rate for targeted beneficial users, and/or the use of an annual dock/sticker fee for boats using the harbor. Unit costs of service will be derived for each alternative based on the associated number of customers for each alternative that will receive the benefits of these services. The City will provide the number of benefiting customers from the available City data. The costs, cost recovery findings, and advantages/disadvantages of each alternative will be 2 discussed with City staff. An important consideration will the cost recovery program's support for the City's overall goal to encourage the use of these current and future sewer pump out facilities, thereby minimizing illegal sewage discharges in the harbor. 2.3 Draft and Final Reports. The costs of these services, study findings, and proposed rates will be documented in a Draft Letter Report of Findings and submitted to the City for review. Integrate City review comments and submit a Final Report of Findings to the City. PROJECT SCHEDULE Based on the preceding scope of work, the Consultant shall submit a draft report of findings for the two tasks within 90 days of the notice to proceed. The final study report will be delivered within 7 calendar days of receipt of comments on the study submission. Should the field Flow monitoring service be required (Task 1.2), the schedule shall be extended for an additional 75 days to contract, schedule, and mobilize a specialized consultant to perform the field evaluation services. Please note that the proposed schedule for project completion is dependent upon several factors outside of our control, including the availability of the required data, City review of submittals, and the scheduling of dry weather field services. Unanticipated delays by these outside factors would prolong the schedule accordingly. CONSULTING SERVICES BUDGET Pursuant to the City's request, we have prepared a budget estimate of our proposed fees for the subject project. The fee for the engineering and financial studies is $25,500, while the fee associated with the field services for Task 2.2 is $35,000, for a total lump sum fee of $60,500. This fee will not be exceeded without written authorization by the City. Should the City elect to not have the Consultant perform all or a portion of the Task 2.2 field services, then the final budget will be discounted by an amount that is proportional to the level of reduced service, with the exception of any increases in unit pricing associated with the reduced number of sites. Please contact us if you have any questions or need additional information. We look forward to continuing our service to the City. Very truly yours, KENNEDYIJENKS CONSULTANTS Roger D. Nuil, V. P. Project Manger RDNIbr 3 EXHIBIT "B" Payment Schedule (Fixed Fee Payment) 1. CONSULTANT shall be entitled to monthly progress payments toward the fixed fee set forth herein in accordance with the following progress and payment schedules. 2. Delivery of work product: A copy of every memorandum. letter. report, calculation and other documentation prepared by CONSULTANT shall be submitted to CITY to demonstrate progress toward completion of tasks. In the event CITY rejects or has comments on any such product, CITY shall identify specific requirements for satisfactory completion. 3. CONSULTANT shall submit to CITY an invoice for each monthly progress payment due. Such invoice shall: A) Reference this Agreement; 13) Describe the services performed; C) Show the total amount of the payment due; D) Include a certification by a principal member of CONSULTANT's firm that the work has been performed in accordance with the provisions of this Agreement. and E) For all payments include an estimate of the percentage of work completed. Upon submission of any such invoice, if CITY is satisfied that CONSULTANT is making satisfactory progress toward completion of tasks in accordance with this Agreement, CITY shall approve the invoice, in which event payment shall be made within thirty (30) days of receipt of the invoice by CITY. Such approval shall not be unreasonably withheld. If CITY does not approve an invoice, CITY shall notify CONSULTANT in writing of the reasons for non -approval and the schedule of performance set forth in Exhibit "A" may at the option of CITY be -suspended until the parties agree that past performance by CONSULTANT is in, or has been brought into compliance. or until this Agreement has expired or is terminated as provided herein. 4. Any billings for extra work or additional services authorized in advance and in writing by CITY shall be invoiced separately to CITY. Such invoice shall contain all of the information required above, and in addition shall list the hours expended and hourly rate charged for such time. Such invoices shall be approved by CITY if the work performed is in accordance with the extra work or additional services requested. and if CITY is satisfied that the statement of hours worked and costs incurred is accurate. Such approval shall not be unreasonably withheld. Any dispute between the parties concerning payment of such an invoice shall be treated as separate and apart from the ongoing performance of the remainder of this Agreement. a2reefformsfexB-1 fixed fec1216i0.3 EXI-1113IT B Fixed Fee Payment 0PURCs ��,`� PROFESSIONAL SERVICE CONTRACTS �„ .,�,� HASING CERTIFICATION RECEIVED 1. Requested by: Todd Broussard, 536-5247 MAR 2 6 2004 2. Date: March 8, 2004 %otHuntingtonBGach �ityAttomey's office 3. Name of consultant: Kennedy/Jenks Consultants 4. Description of work to be performed: Supplemental Study to SMP, CC1249 5. Amount of the contract: $60,500.00 6. Are sufficient funds available to fund this contract?' ® Yes, ❑ No 7. Company number and object code where funds are budgeted: 51185201.69365 8. Is this contract generally described on the list of professional service contracts approved by the City Council'? ®Yes, ❑ No 9. Is this contract within $25,000 or 25% (whichever is less) of the amount stated on the list of professional service contracts approved by the City Council?' ® Yes, ❑ No 10. Were (at least) informal written proposals requested of three consultants? ® Yes, ❑ No 11. Attach list of consultants from whom proposals were requested (including a contact telephone number). 12. Attach proposed scope of work. 13. Attach proposed payment schedule. CHARD AMADRIL, Manager Purchasing/Central Services ' If the answer to any these questions is "No," the contract will require approval from the City Council. Purchasing Certification 3`$.12004 9:13 AM 0 SUPPLEMENTAL STUDY TO SEWER MASTER PLAN, CC1249 REQUEST FOR PROPOSAL SOLICITED FROM: Kennedy/Jenks Consultants Roger Null (949) 261-1577 Richard Brady and Associates Rick Brady (858) 496-0505 Berryman & Hennigar Michael Fakhar (714) 568-7300 • Kennedy/Jenks Consultants Engineers & Scientists 2151 Michelson Drive, Suite 100 Irvine, California 92612-1311 949-261-1577 949-261-2134 (Fax) 18 December 2003 Mr. Todd Broussard, P.E. Engineering Division, Public Works Department City of Huntington Beach, City Hall 2000 Main Street Huntington Beach, California 92648 Subject: Request for Proposal - Sewer Master Plan Additional Hydraulic Evaluations and Financial Services Dear Mr. Broussard: In accordance with our discussions, Kennedy/Jenks Consultants is pleased to present this proposal for additional services related to hydraulic and financial evaluations of the City's sewer system. As the consultant for the City's recent Sewer Master Plan, the additional evaluations can be readily integrated. The associated scope of work, project schedule, and engineering budget are provided in the following. SCOPE OF WORK Taste 1 - Perform Hydraulic Evaluations of Storm Diversion Facilities 1.1 Evaluate the hydraulic implications of including dry weather flows from each of the 15 (9 existing and 6 future) storm water diversion facilities on the City's sewer system. Extract additional sewer pipeline data as necessary to extend the sewer model to each of the identified diversion facilities. Integrate the City provided measured and estimated flows as un-peaked point loads on the existing and future sewer system models to asses the hydraulic implications of continuing the use of these facilities. Meet with the City to discuss the hydraulic modeling findings. 1.2 Based on the findings of Task 1.1 and subsequent direction from City staff, perform a localized field flow study for up to 15 sites to assess the current hydraulic flow conditions downstream of each facility. The localized field study will be based on a data obtained during a 7-day dry weather field flow -monitoring program of the downstream sewer pipeline. The data will be correlated with the diversion facility operation for the existing 9 sites. 1.3 Based on the findings of the above analysis, review the need for a potential modification to the City's design criteria to provide adequate allowance for this additional sewage flow. 1.4 Prepare a letter report of findings to document the findings and recommendations of the previous subtasks. Task 2 — Perform an Incremental Sewer Cost Study In this task, the Consultant will support the City in the performance of a sewer cost study to assess the incremental rate impact of the 0&M costs for the identified diversion facilities and to review and develop a cost recovery strategy for the harbor sewer pump out facilities. The cost recovery program shall consider integrating the cost in the existing maintenance fee, developing a surcharge rate, and/or the use of an annual dock/sticker fee. These services are described in the following subtasks. 2.1 Diversion Facility O&M Cost Recovery Program. In this subtask, the Consultant will integrate the City's costs associated with the diversion facilities into the existing revenue requirements of the sewer maintenance fee. The costs to be identified and integrated shall include the City's O&M costs, applicable permit fees, outside agency pass -through wastewater treatment costs, and other costs related to the management and administration of the diversion program. Once the unfunded costs have been identified, an incremental impact on the sewer maintenance fee will be derived. The incremental impact will be derived by correlating the annualized cost of service with the estimated revenues generated from the current and projected maintenance fee. The un-funded costs will be unitized on a per account or EDU basis and proposed annual maintenance fee adjustments will be derived. 2.2 Harbor Area Sewer Pump Out Cost Recovery Program. In a similar manner to the conduct of services in Task 2.1, in this subtask the Consultant will integrate the City's costs associated with the local harbor sewer pump out facilities into the existing revenue requirements of the sewer maintenance fee. Upon completion of the development of program -related costs, we will develop a cost recovery strategy for implementation by the City. Up to three cost recovery alternatives will be developed. These include integrating the cost in the existing maintenance fee, developing a surcharge rate for targeted beneficial users, and/or the use of an annual dock/sticker fee for boats using the harbor. Unit costs of service will be derived for each alternative based on the associated number of customers for each alternative that will receive the benefits of these services. The City will provide the number of benefiting customers from the available City data. The costs, cost recovery findings, and advantages/disadvantages of each alternative will be 2 discussed with City staff. An important consideration will the cost recovery program's support for the City's overall goal to encourage the use of these current and future sewer pump out facilities, thereby minimizing illegal sewage discharges in the harbor. 2.3 Draft and Final Re orts. The costs of these services, study findings, and proposed rates will be documented in a Draft Letter Report of Findings and submitted to the City for review. Integrate City review comments and submit a Final Report of Findings to the City. PROJECT SCHEDULE Based on the preceding scope of work, the Consultant shall submit a draft report of findings for the two tasks within 90 days of the notice to proceed. The final study report will be delivered within 7 calendar days of receipt of comments on the study submission. Should the field flow monitoring service be required (Task 1.2), the schedule shall be extended for an additional 75 days to contract, schedule, and mobilize a specialized consultant to perform the field evaluation services. Please note that the proposed schedule for project completion is dependent upon several factors outside of our control, including the availability of the required data, City review of submittals, and the scheduling of dry weather field services. Unanticipated delays by these outside factors would prolong the schedule accordingly. CONSULTING SERVICES BUDGET Pursuant to the City's request, we have prepared a budget estimate of our proposed fees for the subject project. The fee for the engineering and financial studies is $25,500, while the fee associated with the field services for Task 2.2 is $35,000, for a total lump sum fee of $60,500. This fee will not be exceeded without written authorization by the City. Should the City elect to not have the Consultant perform all or a portion of the Task 2.2 field services, then the final budget will be discounted by an amount that is proportional to the level of reduced service, with the exception of any increases in unit pricing associated with the reduced number of sites. Please contact us if you have any questions or need additional information. We look forward to continuing our service to the City. Very truly yours, KENNEDY/JENKS CONSULTANTS Roger D. Null, V. P. Project Manger RDN/br 3 Su i� INSURANCE AND INDEMNIFICATION WAIVER r MODIFICATION., REQUEST 1. Requested by: Todd Broussard, 526-5247 RECEIVED 2. Date: January 29 2004 3. Name of contractorlpermittee: Kennedy/Jenks 4. Description of work to be performed: Sewer Study v w+oi Nuntirgtor Gsu_r. P p C` vAicnrie.v of 5. Value and length of contract: $60,5001 1-vear 6. Waiver/modification request: Hold Harmless clause 10 deductible waver 7. Reason for request and why it should be granted: Contract is for a study 1 Consultant is willing to increase insurance to $2,000,000 if necessary in lieu of_0 deductible. 8. Identify the risks to the City in approving this waiver/modification: None known partment Head Signature Date: APPROVALS Approvals must be obtained in the order listed on this form. Two approvals are required for a request to be granted. Approval from the City Administrator's Office is only required if Risk Management and the City Attorney's Office disagree. 1. Risk Management CO�Approved ❑ Denied Signature Date 2. City Attorney's Office 17-11 Approved El Denied.----- Z �gnature ' Date 3. City Administrator's Office ❑ Approved ❑ Denied _ Signature Date If approved, the completed waiver/modification request is to be submitted to the City Attorney's Office along with the contract for approval. Once the contract has been approved, this form is to be filed with the Risk Management Division of Administrative Services WaiverKJ 1/29/2004 2:05 PM Client#: 229 Iv V-f V r uw7T b%_r_Q A IENNECONSI v " - ACORn CERTIFIC OF LIABILITY INSU NCE 01/07/04 °""'' PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION Deaiay, Renton A Associates P. O. Box 12675 ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Oakland, CA 94604-2675 510 465-3090 David Eckman INSURERS AFFORDING COVERAGE INSURED INSURER A:Gr66nWiCh Insurance Company Kennedy/Jenks Consultants INSURER B:Amerlm Ins. CO. 622 Folsom Street San Francisco, CA 94107 INSURER o- INSURER D: INSURER E: COVERAGES . THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING .ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WrrH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION LIMITS A GENERAL LIABILITY GEC001279201 10/01/03 10/01/04 EACH OCCURRENCE 31000000 FIRE DAMAGE ift one fire 51 000, X COMMERCIAL GENERAL LIABILITY CLAIMS MADE OCCUR MED EXP(A one person) 95 D00 PERSONAL a ADV INJURY i1 D00 000 X CU Irx:ludad GENERAL AGGREGATE $2 000 W0 GENLAGGREGATE LIMIT APPLIES PER: PRO DUCTS -COMPIOP AGG s2 000 OW 1-1 POLICY X PRO LOC B AUTOMOBILE X LIABILITY , ANY AUTO MZA.80240112 10/01/03 10/01/04 COMBINED SINGLE LIMIT (Ea accident) $1 ,0wrow BODILY INJURY (Perperson) ; ALL OWNED AUTOS SCHEDULED AUTOS Xi X BODILY INJURY (Peracc)dent) S HIRED AUTOS NON -OWNED AUTOS PROPERTY DAMAGE (Per accident) ; H AGE LIABILITY AUTO ONLY-EAACCIDEN OTHERTHAN EAACC AUTO ONLY: AGG ; ANY AUTO I ; EXCESS LIABILITY OCCUR CLAIMSMADEI I EACH OCCURRENCE ; AGGREGATE ; $ DEDUCTIBLE j ; RETENTION S + B I WORKERS COMPENSATION AND WZC90919476 01/01/04 01/01/05 �( TonywC LIM OTH EMPLOYERS' LIABILITY E.L. EACH ACCIDENT $1 0WI 000 E.L.DISEASE-EA EMPLOYEE ;1 0W0 00 Stop -Gap Uab. iState of IWashin on E.L. DISEASE-POLICYLIMI ;1000000 A OTHER Prof6sSlonal PECO01279301 10/01/03 10/01/04 $1,000,000 per Calm Contractor's $1,000,000 Anni Aggr. Pollution Liab. DESCRIPTION OF OPERATIONS/ LOCATIONSIVEHIC LESIEXC LUSIONS AD DE D BYE N DORSEME NTISPECIAL PROVISIONS GENERAL LIABILITY POLICY EXCLUDES CLAIMS ARISING OUT OF THE PERFORMANCE OF ESSIONAL SERVCES. OVED �� TO FORM: A :NXI�IFEJZ Sewer Master Plan Update - CC1144Pd McGRATH, City Attom,; (See Attached Descriptions) Huntington Beach, City of P.O. Box 190 Huntington Beach, CA 92648 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THEISSUING INSURER WILL MOMAIL30 DAYSWRnTEN NOTICE TOTHE CERTIFICATE HOLDERNAMED TOTHE LEFT. OR AUTHORIZED REPRESENTA VE Ar—ORD 25-5 17/97)1 Of 2 #M97317 DAC 0 ACORD CORPORATION 1988 DE IPTIONS (Continued from age 1) GENERAL LIABILITY ADDITIONAL INSURED: City of Huntington Beach, It Agents, Officers and Employees. For the Pmfssslonal Liability omwage, the deductible has been reduced to -0- for this project, onty. AMS 25.3 (07197) 2 of 2 #M97317 POLICY NUMBER: GECO01279201 COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT. CAREFULLY. ADDITIONAL INSURED - DESIGNATED PERSON or ORGANIZATION This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name of Person or Organization: Huntington Beach, City of ..P.O. Box 190 Huntington Beach, CA 92648 (If no entry apppears above, information required to complete this endorsement will be shown in the Declarations as applicable to this endorsement.) WHO IS AN INSURED (Section II) is amended to include as an insured the person or organization shown in the Schedule, but only with respect to liability arising out of your operations or premises owned by or rented to you. Sewer Master Plan Update - CC1144 GENERAL LIABILITY ADDITIONAL INSURED: City of Huntington Beach, it Agents, Officers and Employees. For the Professional Liability coverage, the deductible has been reduced to -0- for this project, only. APPROVED TO FORM: � NIFER McGRATH, City Attorney CG 20 26 11 85 i • (12) November 3, 2003 - Council/Agency Minutes - Page 12 (City Council) Directed the City Administrator to Make Improvements As Amended to the City's Contracting Processes (Including Professional Services Contracts under Huntington Beach Municipal Code Section 3.03) (120.10) The City Council considered a communication from Councilmember Jill Hardy transmitting the. following Statement of Issue: At the October 20, 2003 City Council meeting, staff recommended improvements to the city's contracting processes. I believe the following recommendations represent effective solutions to recent concerns identified with the contracting process. In addition to the recommended improvements (listed below), I propose that staff provide the City Council an update on the contracting process as part of the FY 2004-05 budget process. A motion was made by Hardy, second (inaudible) as amended to provide that the City Attorney, not Departments will maintain a log of the contracts they enter into which will be transmitted quarterly to the City Clerk's office to ensure proper filing and to direct the City Administrator to make the following improvements to the city's contracting processes within 90 days and provide a report to the City Council regarding the contracting processes as part of the FY 2004-05 budget process: a. City Attorney's office will, upon approving a Professional Services Contract (PSA), transmit the original agreement to the City Clerk's office; and b. Develop an annual training program for processing all types of contracts; and C. Develop Administrative .Regulations to establish the method for processing maintenance/service and public works contracts; and - — d. Contracts will not be dated until they are effective (signed by City Attorney's office); and e. Remove the Mayor and City Clerk signature lines from contracts when not required; and f. Modify Purchasing Manager Certification to apply to maintenance/service and public works contracts; and g. Assign a single department -contract coordinator to ensure contract proper processing; and h. 13epaFtFReRts-City Attorney will maintain a log of the contracts they enter into which will be transmitted quarterly to the City Clerk's office to ensure proper filing; and Staffs professional service agreement signature authority will be capped at $100,000, agreements over $100,000 will require City Council approval. City Attorney Jennifer McGrath clarified for Councilmember Dave Sullivan that her office verifies all documents are accurate, appropriately signed and approved as to form. (13) November 3, 2003 - Council/Agency Minutes - Page 13 City Clerk Connie Brockway responded to Councilmember Dave Sullivan's inquiry relative to why she believed City Clerk attestation on city contracts to be necessary stating that a majority of cities require the City Clerk to always attest to the signatures of city officers entering into contracts on behalf of the city; that attestation by the City Clerk applies to contracts approved and entered into that do not appear on city council agendas and to those contracts which do appear on the city council agenda. The City Clerk informed Council of an email survey her office had conducted of over forty cities wherein all but eight cities required the City Clerk to attest to all agreements even those agreements not appearing on the council agenda. She referred to cities such as the City of Irvine, Santa Ana and Anaheim which require City Clerk attestation to the signatures of the city officers just as the City Clerk must attest to the signature of the Mayor on contracts that go through the city council process. She informed Council of the reasons why she believed her request to attest to in house contracts was reasonable. A substitute motion was made by Sullivan, second Coerper to require attestation and limit contracts to $50,000. City Attorney McGrath stated her opinion that the city seal or attestation line on city contracts is not required. City Attorney McGrath reported on the Huntington Beach Municipal Code Section 3.03 process. City Administrator Ray Silver reported on the Professional Services Contract process stating in order to save staff time his office, the City Attorney and Risk Management developed a standard: . professional services contract. City Administrator Silver informed Council that staff wants to improve the system and address the legitimate concerns raised by the City Clerk. Council voted on the above -mentioned substitute motion made by Councilmember Sullivan. The motion failed by the following roll call vote: AYES: Sullivan, Coerper, Green, NOES: Boardman, Cook, Houchen, Hardy ABSENT: None Council voted on the above -mentioned original motion. The original motion as amended by Councilmember Hardy that the City Attorney, not Departments will maintain a log of the contracts they enter into which will be transmitted .quarterly to the City Clerk's office to ensure proper filing carried by the following roll call vote: AYES: Coerper, Hardy, Green, Boardman, Cook, Houchen NOES: Sullivan ABSENT: None • CITY OF HUNTINGTON BEACH 2 00 0 Main Street P.O. Box 190 Huntington Beach, CA 92648 LETTER OF TRANSMITTAL Attention: Connie Brockway To: City Clerks Office 2000 Main Street Huntington Beach, CA 92648 Fax (714) 374-1573 Date: June 6 -2003 Project/C.C. No.: C.C. No. 1144 Regarding: Sewer Master Plan ® We are sending you: ❑ By Mail ❑ By Fax Mail(Number of pages including this sheet:) ❑ We are hand delivering: ❑ Attached ❑ Under a separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change Order ❑ Other: Item # Copies...'.... Pages Descri lion 1 1 2 Contract Amendment No. 3 with Kenney/Jenks 2 3 4 5 These are transmitted as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ® For your action ❑ Returned for corrections ❑ Return corrected prints ❑ For reviewlcomment ❑ Other: Remarks: In the process of "house cleaning", 1 came across this in my files. never sent to your office for filing. Please contact meat extension 5247 with ny questions you ay have . r- r � It appears that it was 'LL- Tod roussard, Principal Civil Engineer Cc: - U 1144\C0ARFSP\TRANSM \TRANSrOCnYC1ERK1144MC ti+ {�/C I 0 • AMENDMENT NO. 3 TO AGREEMENT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDYIJENKS CONSULTANTS, INC. FOR A MASTER PLAN OF SEWERS THIS AMENDMENT is made and entered into the day of oVe , 2002, by and between the CITY OF HUNTINGTON BEACH, a California municipal corporation, hereinafter referred to as "CITY", and KENNEDYIJENKS, a California corporation hereinafter referred to as CONSULTANT. WHEREAS, CITY and CONSULTANT are parties to that certain agreement, dated October 5, 1992, entitled `'Agreement Between the City of Huntington Beach and Kennedy/Jenks Consultants, Inc., for Master Plan Of Sewers" which agreement shall hereinafter be referred to as the "Original Agreement," and CITY and CONSULTANT wish to amend the Original Agreement as follows: I. TERM The term of this Agreement shall be extended and the services of CONSULTANT shall be completed no later than one year from the date of this Amendment. 2. COMPENSATION In consideration of the performance of services during this extended term, CITY agrees to pay CONSULTANT an additional fee not to exceed Twenty One Thousand Dollars ($2 l ,000.00). 3. REAFFIRMATION Except as specifically modified herein, all other terms and conditions of the Original Agreement shall remain in full force and effect. 02agreemen.kenned} jenks431 G 9.'02 0 • IN WITNESS WHEREOF, the parties hereto have caused this Agreement to be executed by and through their authorized offices the day, month and year first above written. KENNEDY/JENKS CONSULTANTS, INC., By: print name ITS: (circle one) Chairman!Presiden %ice P Bv: vAND a;.-Z print name ITS: (circle one Secretan: hief Financial 01'f3cer./Asst. Secretary - Treasurer CITY OF HUNTINGTON BEACH, a municipal emuoration of the State of California rector of —Public Works APPROVED AS TO FORM: I-- zy�� �7 — City Attorryey 2 -QZ ram }�� 1� 1 REVIEWED AND APPROVED: Cit dministrator 02agreementikennedy jenksp310!9!D2 2 A("IJKI%omn I Irmrm I C Ur LIHDILI I Y IIVOUI"iAMFM I 1213i/02 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION Dealey, Renton & Associates P. 0. BOX 12675 ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Oakland, CA 94604-2575 510 46S3090 David Eckman INSURERS AFFORDING COVERAGE INSURED l(6rVledyJJenks Cortaultanls INSURERA:Gr66nW1Ch Insurance COm y INSURER B:American Im. Co. 622 Folsom Street San Hrar1CISC0, CA 94107 �,., ,,p,' INSURER C:S8CUr1t Ins. Co. of HBrtk)rd INSURER D: �► INSURER E: VFRAr. `C THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WrTH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERT4N, THE INSURANCE AFFORDED BY THE POLICES . DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDMO14S OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPEDFlNSLIRANCE POLICY NUAltil FI POLLCYEFFECTIVE LICYE>PIRATIO LIlufrS A GENERALLIABILITY )( COAAMERCIALGENERAL LIABILI Y CLAIMS MADE OCCUR X CU IncUded GEC0012762 10/01/02 10/01/03 EACH OCCURRENCE 3101M.Ow FIRE DAMAGE (Any cnefIra) 31 0aa 000 MED EXP one paean 35 000 PERSONAL A AOV INJURY i1 000 000 GENERAL AGGREGATE gowm GENLAGGREGATE LIMIT APPLIE5PEit POLICY X PRO- LOC PRODUCTS-COMPIOPA13 = OW 13 AUTOMOBILE X LIABILrrY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIREDAUTOS NON -OWNED AUTOS WAS0234M aPPro TO FOV �Yj, IWTTO-v , City .r•- L„l.� gt Bar : BPuzs' c� 10/01/02 oxmea� O e� 10/01/03 COMBINED SINGLE LIMIT tEa=,dent) s1,00tI,00a BODILY INJURY operpV80nI $ X BODILY ldengRY 3 X PROPERTY DAMAGE pariCCftlsliQ . S GARAQELIA131UTY ANY AUTO -T,�L�►w1. AUTO ONLY-EAACCIDE S EA ACC AUTOONLYN A00 i; EXCESS LIABILITY OCCUR CLAIMS MADE DEDUCTIBLE RETENTION S EACH OCCURRENCE AGGREGATE $ f $ S B WORKERS COMPENSATION AND EMPLOYERS LiAo(LJTY WZC809i2037 .._ _ _ Ai St S EXcept Washington 01/01/03 _ _ 01/01/04 - - 11 wCsrATU- O7H E.L. EACH ACCIDENT t11 000 00a :E.L.OISEASE-EA EMPLOYE $1000000 E-L.DISEASE-POLICYLIM S1,W000 C A OTHE1J Professional ContractorS llution Liab. AEE0700954. PEOD012T93 10/01/02 10/01J02 10/01/03 10/01/03 I $1,000,00D CIeIm/Aggr. I $1,000,OOOCIt�im/Aggr. I DESCRIPTION OF OPERATIONSILOCATIONSIVENICLESIEXDL.USIONSADDED BYENOORSEMEWrISPEMI-PROVISIONS General Liability policy excludes ciatrna arising out of the performance of professional services. Sewer Master Plan Update - CC1144 GENERAL LIABILITY ADDITIONAL INSURED: City of Huntington Beach, (See Attached Descriptlons) HurTtlrVM Beach, City at .... . P.O. Box 190 Huntington Belch, CA 92648 SHOULD ANY OFTHE ABOVE DESCRIBED POLICIES BE CANCELLED BEFOF;ETHE M(PIRATION DATETHEREOF,THEISSUINGINSURER W)LLXW0VWWDMAIL3ft__DAY&WRI"TEN NOTICETO THE CE T FKATE HOLDER NAMEDTOTHE LEFT, OR AUTHORIZED REPRESENT6MVE ACORD 25-S (7t97)1 Of 2 #M82657 DAC o ACORD CORPORATION 1948 0 . ut5(;KIr t IUN5 (uontinued trom rage i) Et Agents, Offers and Empbyees. For the Professional tlabllky coverage, the deduc Uble has been reduced to -0- for this projoM only. AMS 26.3 (07I97) 2 of 2 #M82657 0 POLICY NUMBER: GECO012792 COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED - DESIGNATED PERSON or ORGANIZATION This endorsement modifies Insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name of Person or Organization: Huntington Beach, City of P.O. Box 190 Huntington Beach, CA 92648 (if no entry appears above, information required.to complete this endorsement will be shown in the Declarations as applicable to this endorsement.) WHO IS AN INSURED (Section II) is amended to Include as an Insured the person or organization shown in the Schedule, but only with respect to liability arising out of your operations or premises owned by or rented to you. Sewer Master Plan Update - CC1144 GENERAL LIABILITY ADDITIONAL INSURED: City of Huntington Beach, it Agents, Officers and Employees. For the Professional Liability coverage, the deductible has been reduced to -0- for this project, only. -' �ttor��• D.l • L.'r'^ Y VIM CG 20 26 11 85 CITY OF HUNTINGTON BEACH A 2000 MAIN STREET CALIFORNIA 92648 OFFICE OF THE CITY CLERK CONNIE BROCKWAY CITY CLERK LETTER OF TRANSNIITTAL OF ITEi<I APPROVED BY THE CITY COUNCIL/ REDEVELOPNSENT AGENCY OF THE CITY OF HUNTINGTON BEACH DATE: April 5, 2001 TO: Kennedy/Jenks Consultants ATTENTION: David D. Kennedy Name 2151 Michelson Drive, Suite 100 DEPARTNIENT: Street Irvine, CA 92612-1311 REGARDING: Amendment No. 2 City, State, Zip See Attached Action Agenda Item F-1 Date of Approval 4-2-01 Enclosed For Your Records Is An Executed Copy Of The Above Referenced Agenda Item. L Remarks: Connie Brockway City Clerk Attachments: Action Agenda Page x Agreement x Bonds RCA Deed _ CC: R. Beardsley DPW x x Name Department RCA Agreement T. Broussard DPW x x Name Department RCA Agreement Name Department RCA Agreement Name Department RCA Agreement C. Mendoza x x Risk Management Dept. Insurance x Other x _ Insurance Other x Insurance _ Other Insurance Other Insurance Outer x Insurance ( Telephone: 714-536-5227 ) OTY OF HUNTINGTON BEAR o� aT MEETING DATE: April 2, 2001 DEPARTMENT ID BERTPI -Q � Council/Agency Meeting Held: �'��52- 0) Deferred/Continued to: r4 �Aaproved ❑ Conditi nally Approved ❑ Denied 1f iLs o ity Cl Signature Council Meeting Date: April 2, 2001 Department ID Number: PW 01-004 CITY OF HUNTINGTON BEACH REQUEST FOR ACTION SUBMITTED TO: HONORABLE MAYOR AND CITY COUNCIL MEMBERS i SUBMITTED BY: RAY SILVER, City AdministratordZoy PREPARED BY OOBERT F. BEARDSLEY, Director of Public W rk SUBJECT: APPROVE AMENDMENT NO. 2 TO THE AGREE ENT WITH KENNEDYMENKS CONSULTANTS, INC. TO UPDATE THE MASTER PLAN OF SEWERS AND PREPARE AN INFLOW/INFILTRATION STUDY Statement of Issue, Funding Source, Recommended Action, Alternative Action(s), Analysis, Environmental Status, Attachment(s) Statement of Issue: Should the City Council approve Amendment No. 2 to the Contract with Kennedy/Jenks Consultants to update the Master Plan of Sewers and prepare an Inflow/Infiltration Study? Funding Source: Funds in the amount of $327,000 are budgeted in the OCSD Grant, Account No. 88389003.82600 ($163,500) and Sewer Fund Contract Services, Account No. 21085201.69365 ($163,500). Recommended Action: Motion to: 1. Approve and authorize the Mayor and the City Clerk to execute Amendment No. 2 to the Contract with Kennedy/Jenks Consultants for updating the Sewer Master Plan and preparation of an Inflow/Infiltration Study in the amount of $285,000. 01-004 Apr 2 Broussard(SMP) -2- 3121/01 6:11 PM 0 REQUEST FOR ACTION MEETING DATE: April 2, 2001 DEPARTMENT ID NUMBER: PW 01-004 2. Authorize the Director of Public Works to expend a total of $327,000, which includes the Amendment No. 2 fee of $285,000, estimated contingency of $28,000 and $14,000 in supplemental expenditures. Alternative Action(s): Deny approval of Amendment No. 2 to the contract with Kennedy/Jenks Consultants and direct staff on how to proceed. Delay in approval of this amendment may result in forfeiture of the OCSD grant funding in the amount of $200,000 and jeopardize future OCSD grants. Analysis: The current City Sewer Master Plan was last updated in 1995 by Kennedy/Jenks Consultants, Inc. The Orange County Sanitation District's Cooperative Projects Grant Program (CPGP) requires that an agency's Sewer Master Plan be updated every 5 years. It now also requires that the Master Plan include an Inflow/Infiltration Study in order to be eligible to receive grant funding from this program. The City has already received over $2,000,000 in grants in the last two years from this program and should retain its eligibility for further funding. On March 20, 2000, the City Council authorized staff to apply for funding from the Orange County Sanitation District's Cooperative Projects Program to fund these studies. In July 2000, the City was awarded a grant for a maximum of $200,000 to be matched by City funds to prepare the required study. Kennedy/Jenks was originally selected by the City to develop the 1995 Master Plan through a Quality Based Selection process. Staff was pleased with Kennedy/Jenks Consultant's performance and, therefore, requested and received a proposal from Kennedy/Jenks Consultants to prepare an update to the Sewer Master Plan and prepare an Inflow/Infiltration Study. Due to Kennedy/Jenks' retention of staff involved with the 1995 Study, relative data available, and familiarity with the City's sewer system infrastructure, a cost savings and important continuity of information would be realized by selecting Kennedy/Jenks to prepare these studies. Environmental Status: This project is categorically exempt pursuant to Class 6, Section 15306 of CEQA. Attachment(s): 1. Amendment No.2 to Agreement with Kennedy/Jenks Consultants, Inc for a Master Plan of Sewers, including Approved Certificates of Insurance. 01-004Apr 2 Broussard(SMP) -3- 3121/01 6:11 PM C� ATTACHMENT #1 AMENDMENT NO. 2 TO AGREEMENT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDYMENKS CONSULTANTS, INC. FOR A MASTER PLAN OF SEWERS THIS AMENDMENT No. 2 is made and entered into this 2nd day of April , 2001, by and between the CITY OF HUNTINGTON BEACH, a California municipal corporation, hereinafter referred to as "CITY," and KENN"EDY. JENKS CONSULTANTS, INC., a California corporation, hereinafter referred to as CONTRACTOR. WHEREAS CITY and CONTRACTOR are parties to that certain agreement dated October 5, 1992, entitled "AGREEMENT BETWEEN THE CITY OF HLNTINGTON BEACH AND KE`°NEDY/JENKS CONSULTANTS, INC., FOR MASTER PLAN OF SEWERS" as amended, which shall hereinafter be referred to as the Amended Agreement; and Since the execution of the Amended Agreement, CITY has requested additional work from CONTRACTOR and CONTRACTOR has agreed to perform such work; and CITY and CONTRACTOR wish to further amend the Amended Agreement to reflect the additional work to be performed by CONTRACTOR and the additional compensation to be paid in consideration thereof by CITY to CONTRCTOR, NOW, THEREFORE, it is agreed by CITY and CONTRACTOR as follows: I. ADDITIONAL WORK CONTRACTOR shall provide to CITY such additional services as described in CONTRACTOR'S PROPOSAL DATED December 18, 2000, a copy of which is attached hereto as Exhibit "A," and incorporated by this referenced as though fully set forth herein. 4:'N 4-2t1UI Aercc:rrnt., K4`nedGJ�nk, Anendnent'_ RI_S 2000.; IQ I o-iol 0 • 2. ADDITIONAL COMPENSATION In consideration of the additional services to be performed hereunder as described in Section 1 above, CITY agrees to pay CONTRACTOR an additional sum not to exceed Two Hundred Eighty-five Thousand and no/100 Dollars ($285,000.00). The additional sum shall be added to the amended sum of One Hundred Forty-eight Thousand and no/100 Dollars (S148,000.00), for a new total contract amount of Four Hundred Thirty-three Thousand and no/100 Dollars (S433,000.00). 3. DELETION OF SECTIONS 8, 9, 10, AND 11 OF AMENDED AGREEMENT The following sections of the Amended Agreement are hereby deleted in their entirety: 8. Indemnification and Hold Harmless 9. Workers' Compensation 10. Insurance 11. Certifications of insurance, Additional Insured Endorsements 4. ADDITION OF NEW SECTIONS 8, 9, 10 AND 11 TO AMENDED AGREEMENT New Sections 8, 9, 10 and 11 are hereby added to the Amended Agreement, to read as follows: 8. HOLD HARMLESS CONTRACTOR shall protect, defend, indemnify, save and hold harmless CITY, its officers, officials, employees, and agents from and against any and all liability, loss, damage, expenses, costs (including without limitation, costs and fees of litigation of every nature) arising out of CONTRACTOR'S performance of this Agreement or its failure to comply with any of its obligations contained in this Agreement by 2 4 s: 4-2001 Agreements: Kennedy Jenks Amendment 2 RLS 2000-1191 1; 05'O 1 0 • CONTRACTOR, its officers, agents or employees except such loss or damage which was caused by the sole negligence or willful misconduct of CITY. CITY shall be reimbursed by CONTRACTOR for all costs and attorney's fees incurred by CITY in enforcing this obligation. The CONTRACTOR's indemnification obligations for claims involving "Professional Liability" (claims involving acts, errors, or omissions in the rendering of professional services) and "Economic Loss Only") (claims involving economic loss which are not connected with bodily injury or physical damage to property) shall be limited to the proportionate extent of CONTRACTOR's negligence or other breach of duty. 9. WORKERS' COMPS\TSATION INSURANCE Pursuant to California Labor Code Section 1861, CONTRACTOR acknowledges awareness of Section 3700 et seq. of said Code, which requires every employer to be insured against liability for workers' compensation; CONTRACTOR covenants that it will comply with such provisions prior to commencing performance of the work hereunder; and shall indemnify, defend and hold harmless CITY from and against all claims, demands, payments. suit, actions, proceedings, and judgments of every nature and description, including attorney's fees and costs presented, brought or recovered against the CITY, for or on account of any liability under any of said acts which may be incurred by reason of any work to be performed by CONTRACTOR under this Agreement. CONTRACTOR shall maintain workers' compensation insurance in an amount of not less than One Hundred Thousand Dollars (S 100,000) bodily injury by accident, each occurrence, One Hundred Thousand Dollars (S100,000) bodily injury by disease, each employee, Two Hundred Fifty Thousand Dollars (S250,000) bodily injury by disease, Policy limit. 4 �:4-2001 Agreeme-u: Kenned} JenkN Amendment? RUS 2000-1 t91 l._O,.0, CONTRACTOR shall require all subcontractors to provide such workers' compensation insurance for all the subcontractors' employees. CONTRACTOR shall furnish to CITY a certificate of waiver of subrogation under the terms of the workers' compensation insurance and CONTRACTOR shall similarly require all subcontractors to waive subrogation. 10. INSURANCE A. General Liabilitv Insurance In addition to the workers' compensation insurance and CONTRACTOR's covenant to indemnify CITY, CONTRACTOR shall obtain and furnish to CITY, a policy of general public liability insurance, including motor vehicle coverage covering the PROJECT. The policy shall indemnify CONTRACTOR, its officers, agents and employees, while acting within the scope of their duties, against any and all claims arising out of or in connection with the PROJECT, and shall provide coverage in not less than the following amount: combined single limit bodily injury and property damage, including prod uctsi operations liability and blanket contractual liability, of $1,000,000 per occurrence. If coverage is provided under a form which includes a designated general aggregate limit, the aggregate limit must be no less than S 1.000,000 for this PROJECT. The policy shall name CITY, its agent, its officers, employees and volunteers as Additional Insureds, and shall specifically provide that any other insurance coverage which may be applicable to the PROJECT shall be deemed excess coverage and that CONTRACTOR's insurance shall be primary. Under no circumstances shall the above -mentioned insurance contain a self - insured retention or a "deductible" or any other similar form of limitation on the required coverage. B. Professional _Liability Insurance CONTRACTOR shall furnish a professional liability insurance policy covering the work performed by it hereunder. Said policy shall provide coverage for CONTRACTOR's professional liability in an amount not less than $1,000,000 per occurrence and in the aggregate. A claims -made policy shall be acceptable if the policy further provides that: a:c: 4-2-4.11 Auccricn,.s: Kc• ncdv',Icri1-s Amcndment 1. 1:05'0 I The policy retroactive date coincides with or precedes the initiation of the scope of work (including subsequent policies purchased as renewals or replacements). 2. CONTRACTOR will make every effort to maintain similar insurance during the required extended period of coverage following project completion, including the requirement of adding all additional insureds. 3. If insurance is terminated for any reason, CONTRACTOR agrees to purchase an extended reporting provision of at least two (2) years to report claims arising from work performed in connection with this Agreement. claims. 4. The reporting of circumstances or incidents that might give rise to future 11. CERTIFICATES OF INSURANCE Prior to commencing performance of the work hereunder. CONTRACTOR shall furnish to CITY certificates of insurance subject to approval of the City Attorney evidencing the foregoing insurance coverages as required by this Agreement; the certificates shall: A. provide the name and policy number of each carrier and policy; B. shall state that the policy is currently in force; and C. shall promise that such policies shall not be suspended, voided or canceled by either party, reduced in coverage or in limits except after thirty (30) days prior written notice; however, ten (10) days prior written notice in the event of cancellation for nonpayment of premium. CONTRACTOR shall maintain the foregoing insurance coverages in force until the work under this Agreement is fully completed and accepted by CITY. The requirement for carrying the foregoing insurance coverages shall not derogate from the provisions for indemnification of CITY by CONTRACTOR under the Agreement. CITY or its representative shall at all times have the right to demand the original or a copy of all said policies of insurance. CONTRCTOR shall pay, in a prompt and timely manner, the premiums on all insurance hereinabove required. 4 s: 4-2001 A`;reemems: Kernedy J.rk: Amendment 2 KI S 2000-: 19: 1:05:(11 • 5. REAFFIRMATION Except as specifically modified herein, all other terms and conditions of the original agreement shall remain in full force and effect. IN WITNESS WHEREOF, the parties hereto have caused this Agreement to be executed by their authorized officers on the date first above written. KEN- EDY%JENKS CONSULTANTS, INCH., a California corporation Name DdQTA, D ue(411 edq- (tv-pe or vdal CITY OF HUNTINGTON BEACH, a California municipal corporation NA , f�uc�Nc. Mayor ATTEST: Its (circle one) Chairma(resident: 'ice President , AND City Clerk 0�-QifOl By: 3I,� � APPROVED AS TO hORW Name J)0ih9yD !P, u%r���✓ or print) Its (circle one 9,C4,1rA,ejstant ssistant Secretary:' Chief Financial Treasurer REVIEWED AND APPROVED: Cit dministrator 4, 4-210 i Agreeircns: KeMcdv Jenk, Aniendlrent 2 JU S 2000-: 191 1`(1S 01 City Attorney �Dl INIITIATEPjAND APPROVED: t— Direc;w6f Public Works 13' 18 December, 2000 Mr. Todd Broussard Associate Civil Engineer City of Huntington Beach 2000 Main Street PO Box 190 Huntington Beach, CA 92648 Kennedy/Jenks Consultants Engineers &Scientists 2151 Michelson Drive Suite 100 Irvine, California 92612-1311 949-261-1577 FAX 949-261-2134 Subject: Proposal for Engineering Services Sewer System Master Plan and Infiltration and Inflow Analysis Dear Mr. Broussard: Per our discussion, Kennedy/Jenks Consultants is pleased to submit our proposal for the conduct of the subject project. As you are aware, our firm prepared the City's last comprehensive study in 1995 and offer the City the continuity of ongoing utility engineering and management support services. Clearly one of the most significant requirements to accurately preparing evaluations of this nature is a familiarity and knowledge of the entire sewer system and to understand how it functions internally as well as how it interacts with adjoining systems or subsystems. The process of understanding a sewer system requires significant effort. This effort, in combination with the development of a hydraulic model, is the cornerstone of any master planning effort. Our local Irvine office is in possession of a significant amount of this data (current, historical, and future data and record drawings) and has already obtained a thorough understanding of the City system and functionality. This familiarity and experience will result in both direct and indirect cost savings for the City. We believe that we have developed a comprehensive approach to the City's requested services and have integrated additional services that would provide value to the City. We would be pleased to further discuss our proposed project work plan. Please contact us if you have any questions or need any additional information. Very truly yours, KENNEDYIJENKS C NSULLTANTS e-,� 7/41 1 Roger . Null Vice President RDNIbr KENNESENKS CONSULTANTS SEWER SYSTEM MASTER PLAN UPDATE & INFILTRATION AND INFLOW STUDY BACKGROUND The City of Huntington Beach is an urban city with a population of approximately 200,000 residents. The City's last Sewer System Master Plan was conducted by Kennedy/Jenks Consultants in 1995. This comprehensive plan developed a hydraulic model of selected facilities, evaluated the condition and capacity of the City's 29 sewer lift stations, projected long-term impacts of growth on system infrastructure requirements, developed a phased capital improvement program (CIP), and developed a dedicated sewer use charge that would be necessary to support a new sewer enterprise fund. To support the regional wastewater activities of the County Sanitation Districts' of Orange County (CSDOC) and evaluate the implication of new development, the City desires to update the 1995 Master Plan. This updated plan must bridge beyond the typical master plan scope of work to develop and integrate derived Infiltration and Inflow (I&I) values in the Master Plan findings and recommendations. By integrating the scope of services of these two studies under one project work plan, the City will avoid the duplication of substantial work efforts and increase the depth and breadth of the final work products. It is for these reasons that the City has requested Kennedy/Jenks to provide this proposal for the combined Sewer System Master Plan and Infiltration and Inflow (1&1) study. INTEGRATED STUDY SYNERGY The conduct and integration of the Master Plan and 41 Study will provide additional synergy for the City of Huntington Beach's wastewater system planning work. This synergy is most pronounced in the following areas: • A substantial amount of remedial measures are developed based on a condition assessment of the system. This assessment is a general component of both studies. • Both studies require the measurement and/or estimation of flows in various basin/sub- basin areas of the City and a level of coordination with CSDOC. Available Geographic Information System (GIS) data will increase the efficiency and effectiveness of performing the land use and underground facility evaluation elements. New data is proposed to be created in GIS coverages to further enhance the City's investment in this valuable management tool. These areas of study synergy, as well as the continuity and understanding of the master plan update provided by Kennedy/Jenks, will result in both direct and indirect cost savings for the City of Huntington Beach. pAprojecwhuntinpton aeachtnal 1)rcpcs01lamp20002.doc KENNE&ENKS CONSULTANTS BASIS OF APPROACH While there are a number of scoping issues undetermined at this time, Kennedy/Jenks Consultants has developed a methodical approach to the multi -tasked project based on the following: • Discussions with City Engineering and. GIS staff • Maximum usage of available data to perform the required services • Cost control strategy that utilizes desktop evaluation techniques to qualify I&I conditions and substantiated by field observation data as required • Appropriate development and usage of new data that will enhance the City's sewer system GIS data and coverages • A focused list of project goals and obbjectives • Our in-depth knowledge and understanding of the City's Sewer System gained through the conduct of the City's prior Sewer Master Plan • Our experience in the performance of Sewer Master Plans, Infiltration and Inflow (I&I) Studies, and Sewer System Evaluation Studies SEWER SYSTEM MASTER PLAN UPDATE OBJECTIVES Based on discussions with City staff, the basic objectives of this project is to update the 1995 Sewer Master Plan produced by Kennedy/Jenks to create a current, comprehensive, and accurate planning tool. The proposed approach to achieving the City's objectives in an efficient and cost effective method will include the following considerations and options: • Kennedy/Jenks will provide the same local team members that created the last master plan as the team to produce the update. This will provide the City with a continuity and understanding to the master plan update that will result in both direct and indirect cost savings. • Utilize the 1995 Master Plan and all previously collected documents, data, and files already located at the Kennedy/Jenks Irvine office as a basis to evaluate, identify, and incorporate any revisions that affect system characteristics, evaluation criteria, or flow criteria. • Utilize the new City Geographic Information System (GIS) to facilitate data revisions, automate the exchange of that data, and establish a continuity of current system facility data, planning data, and land use 1 zoning data with the updated sewer master plan. • Incorporate the upcoming comprehensive Inflow & Infiltration Study to provide a significant higher level of flow characteristic accuracy and model calibration. • Develop an updated digitized map of the sewer system schematic evaluated for the master plan, as well as an updated service area map based on the 1995 Master Plan and current GIS data. • Update the hydraulic evaluation model, capital improvement program (CIP), and master plan documents. p-`.projectelhuntinmon beaanl0inai prop=rsarop2W0_2.dac 2 0 KENNE&ENKS CONSULTANTS SCOPE OF SERVICES The following Scope of Services and Project Approach was developed from our knowledge of the City's sewer system obtained during development of the 1995 Master Plan, and recent discussions with City staff. Task 1 — Review New or Revised Plannina and Facility Data Meet with the City to establish specific project goals, needs, and desires for the proposed study. Establish departmental contacts and discuss revised data availability. rrent Plannina and Kennedy ,Jenks is in possession of all documents and data utilized in the completion of the 1995 Master Plan and will only be required to review reports by the City of Huntington Beach and/or consultants to the City that are new or revised since completion of the 1995 Master Plan. The review will include any new Specific Plans, land use / zoning data revisions, system video work, and any sewer system information available from the City Engineering and Planning Departments. This information will be compared to previously obtained documents and evaluated for incorporation to the master plan update. We understand the City has recently completed or will soon complete rehabilitation projects in the downtown area and "island areas which will be incorporated in the update. Subtask I.C. -- Evaluate Current Sewer Flow Criteria We will review any current land use, and flow data to update sewage flow/load criteria for appropriate types of user classes. Land use, occupancy densities and population will be reviewed for consistency with metered discharges from the City to the OCSD sewer system. The land use data and flow rates identified in existing reports will also be checked to approximate peaking factors, infiltration and inflow, and peak wet weather and peak dry weather flows. The relationship between average sewer flow and peak sewer flow will be reviewed and compared to previous Master Plan peak factors, as well as those for comparable Southern California sewerage agencies. The City will provide the land use and General Plan data in a shape file to the Consultant. Subtask 1 Q...: Assess Non -Huntington Beach Generated Sewage Flaws We will compare Non -Huntington Beach Generated Sewage Flows identified and quantified in the 1995 Master Plan to current data and adjust accordingly. Task 2 — Flow Criteria Develooment and Flow Protections Previous Population Proiection The "design population" forecast developed in the 1995 master plan will be compared with current forecasts for the study area and revised as appropriate. Land use projections will be provided by the City staff and will include the user classes as identified in 1995 master plan. The projected population as defined in the City's updated General Plan will serve as the basis for future projected growth through the year 2020. p1projectaknumington beacnYfinal proposa1'%prop2000_2.doc 3 0 KENNEOJENKS CONSULTANTS Subtask2.B. — Review Flow Criteria and Flow Projection The criteria used in the 1995 master plan for sewer system description and analysis will be evaluated and modified to accommodate revised data and documented for review by the City. This methodical approach is intended to provide the City with an understanding of the plan for estimating existing and future sewer flows and establish the methodology for future updates. The draft criteria will be finalized after the development and compilation of additional data is derived from sewer system flow monitoring. Subtask 2.C. — Develop Desion and Unit Cost Criteria Evaluation of the sewer system requires the development of key design criteria. Design criteria will include the type of sewer use (backbone vs. local), maximum depth of flow, pipeline roughness coefficients, minimum velocities, peaking factors, I&I criteria, and lift station operating guidelines. These criteria will be based on City standard specifications, prior master plan criteria, physical and hydraulic pipeline conditions, discussions with City staff, existing literature, model requirements, and our experience on other similar projects. These criteria will be documented for review and concurrence by the City prior to incorporation in the system analysis phase of the project. In addition, unit cost estimates will be based on pipe materials, size, depth of construction, trench width, etc. These defined cost parameters are used to estimate the design and construction costs of underground facilities. The engineer's estimate of probable costs for above ground facilities will be derived on a case -by -case basis. Task 3 - Sewer Sv—stem_Conflauration and Model Development task 3.A. - Renewer Svstem Modelin Building on the system modeling schematic established in the 1995 master plan, we will utilize the City GIS facility data to revise and incorporate any changes. Based on a review of the system revisions and discussions with City staff, we will select the appropriate City owned sewer lines to be modeled, integrate the appropriate pump station facilities, and develop an updated sewer system modeling schematic. This schematic will be indicated on the City GIS basemap and submitted to the City for approval. Upon approval, the City will provide GIS shape files and/or record drawings of the facilities to be digitized and incorporated in the evaluation model. - U ddateTributary Are We will update the 1995 Master Plan service area tributary basins and sub -basins to correlate with system revisions defined in Subtask 3.A. A map will be developed showing the system service areas tributary to the updated model schematic and proposed limits for sewer service. The updated map will be developed using the current GIS basemap depicting the entire sewer system and parcel boundaries. The updated tributary area map will be supplied digitally to the City for addition to the GIS system. z=ta�K;�,u_ - L)eveiop_-.)ewer riows ana moaei, ;a ration The 1995 Master Plan identified 4 major drainage basins that are tributary to non -City trunk lines. To establish current land use loading conditions and support model calibration, we propose to flow monitor up to 12 locations in the City. The focus of this monitoring program is to isolate and pAprojectskhuntinptpn peEkcnkfinal proposal'orop2000_2.0ac 4 0 KENNE&JENKS CONSULTANTS assess the various land use flow characteristics within the City, but will also be used to support model calibration and the associated 1 & I study performed in subsequent tasks. Given this purpose, the monitoring program derived herein is proposed for a 7 day duration. In support of the I&I study, 24-hour composite samplers may also be installed to collect wastewater samples for laboratory analysis related to background strength and/or chloride concentrations. The flow generation results will be compared with the values developed in the 1995 Master Plan. Using the parcel to Utility billing system correlation desktop study performed as an element of the I&I study, we will quantify the average water consumption used in each service area, compare it with the flow monitoring results, and evaluate the appropriateness of the resulting return -to -sewer ratios. The model will be loaded based upon the acreage of each land use tributary to the modeled facilities in combination with the updated sewer generation factors derived herein. A hydraulic computer model is anticipated to be used to efficiently and effectively utilize the available GIS data. s !fA , 9 1IRTZ, 7--Td&VA M A meeting will be held with the City operating and engineering staff to ascertain the current status of known problem areas from 1995 and present. Capacity problems will be discussed using the system schematic as a basis of reference. Subtask 4.B. - Model pnd AnalyZe Exi5t1ng Sewer System The hydraulic adequacy of the existing system will be analyzed as a multi -step process. The first step is to impose the actual land use sewer flows on the sewer system input file of the computerized modeling program. The modeling simulation will be conducted and the results calibrated with the supporting monitoring data. Once the model is calibrated, actual land use sewer flows will be converted to "design loads" and the system will be re -modeled. This "design loaded" simulation will provide the basis for analyzing existing deficiencies as the model will output the total flow verses capacity for each identified reach. Once set up, the model will be a convenient tool to analyze changes in land use, peaking factors, pipeline diameters and/or build - out conditions. Subtask 4.C. - Corap'LeExisting System -Deficiencies Once the "current condition" simulation of design loads is run, a list of existing deficiencies will be compiled and presented to the City. Portions of the system with excess capacity will also be identified. aubtask 4.D. -Model an-i_Analyze Future Sewer System The projected ultimate demands at the year 2020 will be imposed on the sewer system model utilizing the land use overlays and sewage flow estimates of previous tasks. The system model will address pipeline capacities required to meet the anticipated future flows. pAprojecla'•hunlinglon oeaehlftnal propMallprop2000_2.doc 5 KENNEOJENKS CONSULTANTS Improvements will be recommended to address existing sewer deficiencies and to meet the projected demands in the year 2020 and to incorporate methodical pipeline replacement requirements. Tables will be used to summarize pipeline sizes, materials, slope, capacity, design flows, and estimated construction costs and schedule. The recommended improvements will be keyed to a plate for illustration and prioritized according to need, anticipated schedule and costs, and will be separated into cost components of new capacity and existing demands for compliance with Government Code 66000-66024. Based on the results of the previous tasks, recommendations will be developed to provide adequate pumping/lift station capacity and identify pumping station capacity improvements. Pump station data from the 1995 Master Plan will be used to evaluate existing pump station performance, supplemented with updated information provided by the City if applicable, and updated capacity evaluations will be performed. Summary tables will be prepared showing recommended improvements and associated costs. Improvements will be prioritized according to need, and anticipated schedule. Costs will be segregated in compliance with Government Code 66000 to 66024. Per discussions with City staff, no field evaluation services are included in this subtask. The information gained through the performance of the previous tasks will be presented to the City as its 2001 Sewer Master Plan. Five (5) copies of the draft report and associated master plan maps will be provided to the City for review. Upon receipt and incorporation of City comments, fifteen (15) copies of the final master plan document and master plan maps will be prepared and submitted to the City. The master plan documents will include the findings, conclusions and recommendations of the tasks described above, along with appropriate system layouts, graphs, tables, maps, and criteria used in the investigation and analysis of these sewer facilities, p broi".s IunGnpton beach%rmal proposahprop2000_2.doc 6 • KENNEIAJENKS CONSULTANTS INFILTRATION AND INFLOW STUDY GENERAL APPROACH As discussed, there are a number of approaches that may be utilized to conduct an Infiltration and Inflow (1&1) study. The most common approach is to perform a substantial level of localized flow monitoring of major sub -basins and known priority areas under a variety of dry and wet weather conditions for each area. While this approach is effective at deriving the necessary data to perform an I&I evaluation, it is both expensive and time consuming. Moreover, since infiltration may currently be present during dry weather conditions, this approach used without additional data may not produce reliable results. With the development of enhanced computer technologies including the use of the Geographical Information System Software and pump station telemetry data, there are number of approaches that are now available to scrutinize the system's performance and subsequently screen the system's potential for I&I problems. Proceeding in this methodical manner, the more common and expensive services are only utilized to further evaluate areas that have conditions present which one would presume to contribute to a probable I&I deficiency. Our proposal is based on utilizing this modular approach to efficiently perform the I&I study for the City. SCOPE OF SERVICES As previously discussed our approach to this study is based on a modular methodology. Each evaluation task will narrow our focus to isolate the areas with I&I problems. In general, the unit cost to further screen and identify problem areas will increase with each subsequent phase and task element. As such, the methodology that imposes the highest unit cost in its evaluation will be used only as required. It should be noted that while this approach provides a cost effective method to the conduct of studies of these types, it does not lend itself to the development of a final budget. This condition exists due to the fact that the magnitude of services required for each task is not definable until its predecessor task activity is complete. Accordingly, our total project budget is based on a probable not to exceed value. The budget for each Phase 2 task module will be submitted to the City for review and approval prior to the initiation of each task. The probable modular order of tasks that will be performed herein is provided as follows: PHASE 1 PERFORM DESKTOP STUDY The services associated with this task focus on the collection, review, and analysis of currently available data to screen and the City"s sewer system for I&I problem areas. The data that will be substantially utilized in the desktop evaluation includes: any prior studies that were performed by/for the City (sewer or storm) or by/for CSDOC (Sewer) within the City's service area or by/for Orange County (Stormwater) within the City's service area that evaluated I&I, performed flow monitoring, video inspection, chemical analysis, dye testing, smoke testing, or rainfall evaluation services. Additional data that will be required is a shape file of the City's sewer facility data (for age and material), a shape file of the City's APN data base information (including land use), a digital file of the water billing data at a per account level (detailed requirements to be provided) from the City's utility billing system, pump station run time records, known old inferior manhole locations, known root intrusion areas, known sewer low points/creek areas, groundwater elevation data, rainfall data, and storm drain channels information, to the extent each exists. paprojects'nan.fngton beachlrna: proposaKprop20D0 2.doc KENNE&ENKS CONSULTANTS In this subtask, we will review and evaluate the pump run time data for each of the City's 29 pumping stations. We will locate these facilities on a map to facilitate an overlay evaluation of applicable impact from high groundwater levels, and/or seawater intrusion, and will contrast the run time data with rainfall station data and tidal chart activity. From this evaluate, we will identify which pump stations have apparent [&I problems for further review. If substantial wet weather data is available, then facilities with minimal change in pump run time activity will all but conclude the I&I evaluation of the facilities in the tributary areas. The final conclusive exclusion criteria is if there are no known problems within any of these area and if the pipeline -age and material values meet acceptable standards. In this subtask, we will review and evaluate the location and depth of underground sewer system facilities (pipelines and manholes) to ascertain if these facilities may be under the influence of known infiltration sources. Accordingly, we will overlay the location of the City's sewer facilities with the existing groundwater basis, storm drain channel alignments (specifically unlined), and the seawater areas in the harbor. We will correlate the depth of the sewer facilities with the seasonal depth of the groundwater tables, the depth and soil conditions of the storm drains in common alignments, and the oceanographic tidal chart to identify probable infiltration areas based upon the potential influence of these key factors. The areas that have a high correlation with any of these factors will be further scrutinized by one of several alternative methodologies. a I • 1 • l . 11 • ' • • • I • • . 11 The purpose of this sub task is to correlate the current Assessor Parcel Number (APN) data file with the City's utility billing system data file for ongoing management and evaluation purposes. Data cleaning is limited to street name data, as this data field is one of the primary fields of data correlation. The conduct of this task is described as follows: Meet with the City Engineering, GIS, and utility billing department staff to discuss the availability and format of data deliverables. 2. Obtain current parcel -level APN data and account -level utility billing account data from the City in a digital file format. Utility billing data to be focused on master account record data, excluding consumption characteristics. 3. Clean APN and billing account record street name data and parse utility account field data as required to support data correlation. 4. Correlate the digital account -level information derived form the City's utility billing system with digital parcel -level tax assessor data, based on owner name and/or street address. p:tprojenetnuntmpton heaelPsnal propa8alProp2000_2.doc 8 • KENNE&ENKS CONSULTANTS 5. Prepare a listing of utility billing system accounts that are not ' included in the County tax records (Non -Correlating Billing Accounts). Prepare a listing of parcels that are not included in the City's utility billing system (Non -Correlating Parcels). 6. Geocode the non -correlated billing system and APN data files and prepare a plot of findings. Review the check plot findings to identify additional correlating data. 7. Draft Review. Review the listing of Non -Correlating Billing Accounts and Parcels with the City. With the City's assistance, attempt to identify the appropriate billing number/parcel number for each record. Field verification/resolution assistance to be provided by the City, as required. 8. Final Submittal. Integrate the additional data, and provide a digital file to the City to update the utility billing system and County tax roll data files. Update shall include cleaned street name data (both data sources) and associated APN number in the utility billing system data. Evaluation rgea In this subtask we will utilize the APN to water account correlation findings of the previous subtask to: develop APN/utility accounts per sewer basis/subbasin, calculate average annual and seasonal water demands per sewer area, and by applying the updated Sewer Master Plan discharge values, estimate the quantity of wastewater generated in each area. Upon the completion of this evaluation, we will compare the developed sewer flow values with available data to screen isolate areas with probable I&I conditions. sk 4 - Prepare DesktopiReport of Findings In this task, we will summarize the results of the previous tasks and subtasks in a report of findings. We will prescribe the appropriate next steps and matte recommendations for the most viable methodology for further quantification in the next phase of services. We will submit 5 copies of a draft report for City review. We will meet with the City and integrate City comments in the submission of a final report. The scope and budget elements of the subsequent task will also be prepared and submitted to the City. PHASE 2 PERFORM FIELD I&I EVALUATION PROGRAMS k 1 -Video Insnectio Upon completion of the overlay analysis of the City's pumping and piping facilities, we propose to perform a video inspection of the pipelines in those areas that have a high correlation with the infiltration sources. We will video inspect each of these areas (preferably during low flow) to identify the specific problem. This activity will be used to support the I&I Program through the deployment of field personnel to physically view identified manholes for infiltration seepage and/or infiltration water stains and markings. While this activity will not readily ascertain the quantity of the I&I problem, it will be an important element in the overall 1&I reduction plan. pAprojectsthunhngton Deachlr.nai proposa.Vrop2000_2.doc 9 0 KENNE&ENKS CONSULTANTS A series of 24-hour composite wastewater samples will be obtained to perform a chemical analysis of the wastewater quality on the areas with probable I&I related to seawater intrusion. The chemical analysis will focus on the quantification of chlorides to identify this I&I source. Additionally, wastewater sampling may be performed during wet weather conditions to establish the level of dilution to the baseline wastewater constituents associated with I&I. •. 1l•1 i• •. .0 To obtain additional data related actual wastewater flow conditions, we will perform flow monitoring of specific areas that require additional quantification of wastewater flow conditions. Depending on the results of the previous tasks, this flow monitoring program may be purposefully conducted to obtain both dry weather and we weather conditions. Accordingly, the duration of this program may be substantial to capture the data associated with a wet weather event. •. - . •M--•X • !� �• In this task, we will summarize the results of the previous phase, tasks and subtasks in a report of findings. We will formalize the remediation alternatives and derive the proposed methodology for each I&I source and area. Based on the recommended alternative, cost estimates will be prepared and a priority ranking for each source/area will be developed. The findings and implementation recommendations of this study will be documented in a report. We will submit 5 copies of a draft report for City review. We will meet with the City and integrate City comments in the submission of a final report. PAPrDjectsWantfngton heachlfna! proposaHprop2000_2.0oc 10 0 KENNESENKS CONSULTANTS PROJECT SCHEDULE Personnel can be assigned to the project and work can begin immediately after execution of an agreement. It is projected that the Draft Sewer System Master Plan and Infiltration and Inflow Study can be completed within 9 months from the receipt of the notice to proceed. The final report can be completed within three (3) weeks following receipt of City comments. Please note that the proposed schedule for project completion is dependent upon several factors outside of our control, such as the availability of the required data, and City review of draft submittals. Unanticipated delays by these outside factors could prolong the schedule accordingly. CONSULTING SERVICES BUDGET ESTIMATE Based on our understanding of the project, our experience on similar projects, and our scope of services provided herein, we have prepared a consulting services budget for the City's Sewer System Master Plan and I&I Study. As previously discussed, given that the budget for Phase II I&I tasks is based on the findings of Phase I tasks, the budget recommended herein is an encumbered value. The actual budget for Phase II will be developed and submitted to the City for review and approval upon completion of Phase I and prior to the initiation of Phase II activities. The proposed lump sum budget is as follows: + Sewer System Master Plan - $`1-4-1;000 + 1&1 Study Phase I Desktop Study- $ 48,000 + 1&1 Study Phase 11 Field Services (Time and Materials, Not to Exceed) - $ 100,000 + Total Project Budget - $-216�9;980 Our proposal shall remain effective for a period of not less than ninety (90) days from the date of this submittal. piprojecls4huntmgion beachYnal propmAprop2U0Q_2.doc 11 02i26/01 14:50 FAX 949 261 2134 1/15/01 2:11 PM 1-510-4W2193 .-.� �L _ •inn KEtiNEDY JENKS CONSULT 1--949-261034 *TT.•>u r'nT Tc Z. 002 002 Al ORD CERTIFICATE OF LIABILITY INSURANCE DAT 1 /IT/0 -, "' PKODUCER Dealey, Renton & Associates F . O . Box 12675 Oakland, CA 94604-2675 510 465-3090 David Eckman THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERi1r"ICATE HOLDER THIS CERTIFICATE DOES NOT AMEND. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVEItAG£ NSl`rD Kennedy/Jenks Consultanns, Inc. 622 PolsoT. Street San 1=rarciSCO, CA 94107 iNS-JRBRA- Commerce & industry I„S„Reza. Amer_ —can Insurance Company INSJUERc: Security Ins. Co. of Fa;t c,d WSiIR(?R LI: INSURER B: r'III V . . rrc THE POLICIES OF DMUIIANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAEv1ED ABOVE FOR THE POLICY PERIOD INDICATED- NOTWI H T.aLNDIN' ANY REQUIREMENT. -MRM OR CONDITION OF &NY CONTRAL-r OR OTHER DOCUMENT WITH RESPECT :O WHICH THIS CERTIFICATE MAY BE ISSOP:I o MAY FHR'A:N, T"RE INSURANCE AFFORDED BY T14E POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TEILMs, EXCLUSIONS AND CCNDMONS OF 51-'C` POI_:C:ES A03U :ATP. I-Ily( •I'S SHOWN MAY HAVE BEE. REDUCED BY PAID CLA--AS. N�1 TYPE OF I NSURANCE _4 POLICY NOMEER POW CY&PFLCnv& POLICY E'.J(PIRA?ION L,tiI1Ta A !:FNF.JI.4LLIABILITY GL417-78-03 10/Ol/00 l0/01/01 EACH OCCURRENCE f1 OQv Rol' P:RB DAMAGE' — Gr.) i t l 0 0 0 Q 0 0 RCVd-GENERALLIAB;LITY CLni+5 MADE }OCC 7 Q §tanoP..�N FBRSCVAL &ADV INJURY L1 0nC 000� CI,cluded 1+.IC—II GENERALAGGRSGATE % 2 Q 0 O 000 PRODUCTS-COMPIOPAGG L 2 0 0 0 0 0 0 ICBN'LAGCRn GATE LIMRAPPL!5S PER: i 1 c0L-CY I X PAO LOC B A;70tIOD1 LE LIABILITY ' X ANY AUTO DZA80214937 10/01/00 10/01/01 COM6i,V8C. SWOR-S LIM17.1 1 r�Qc ODD 1 V , BOO!LY INJURY L A..-OW'4RD A';-W S`4E=1:..ED A.'TCL I �� d� O) R� � X I X v�7N-cwNeD AIRas ' APPROVED AS TO FO s GAIL HUTTON CITY ATTOPE21Y _ PRCPERTYDAMAGE 'Pcr—Ide;LL) L GARAGE LIAEI:.ITY By: AUTO ONLY - BA ACCIDENT �S �EIRTHAN ONLY: PA ACC �L AGC L RANY AUTO Do ty A t me EXCESS IJABILITY -^ O'`'CSR El CLAIMS MADE BA::}; OCvIJRRE\CB I I AGGRECATS L i ' LE711C?'IBLE G I R3T 3.�TION S H WORKERS COUPENSAT[ON AND DZN80869628 01/01/01 y 01 /01/02 }� WC STATE- O' - EN PLOY L:IL4 LIABILITY I „ 11 States Excep L' E.L. RACH ACCIDENT n S 1 0 0 0 Q Q 0 L11. 000 00'0 Washington B.L.DISBA58-EAEMPLOYHE 1 S 1 0 Q C C v Q `B.L. O;98ASE - POL:C -IMIT C 1—liERProfessional CPL508242 10/01/00 10/01/01 1,000,000 per Claire. Contractors Lilut-jor. 1,000,000 Ar_nl. Aga. Liab . DUICR:P':':Ov OF OPERATIONIILOCA IIONSlVEH1CLESIMCLU91ONS ADDED RY ENDORNP-MF.NT1SPFCIAL PROVISIONS Sewer Master Plan. Update - CC1144 GENERAL LIABILITY ADDITIONAL INSURED: City of Huntington Beach, 4t Agents, Officers and Employees. Deductible is $10,000 For the Professional Liability coverage, the deductible has been reduced Li.2- -0---for this project, only. SHOULD ANYOPTHEABOVE DESCRIBED POL:Cus BECA4CELLED BEFORETHEEX?rRdq":O%' .-"- in-ington Beach, City of DA :'E ?H£RCOF, ".'NE IRRJING INSURER W1:.L]t��Nj=]Q'0t%7A:1��n—DAl'E W:cfl^]iN P.O. Box 1-90 NO"10ETOTHE CERTIFICATE HOLDER NAMED TOT. HE:&F-,j0TyALMXXffl9QR.XDC-X Huntington Beach, CA 92648 xa¢�aaeEyo�caracE�cxsaaeumec�ao�nmeasxxscExaxlx AUTHOR: LED REPRMNTATT Acorn zs-S (7197) 1 of 1 # M16472 DCE 6 ACORD CORPORATION 1988 CITY OF HUNTINGTON BEACH APPLICATION FOR INSURANCE REQUIREMENTS WAIVER OR MODIFICATION k S2*-) 1. Name/Title/Department of Requesting Staff Member�NQM FVAUM 42D, . CIVIL. CrWhtti•_ � �• �:1� 2. Date of RequestO Z 6401 3. Name of Contractori?errnittee_ KE'Nh) I le-S Cow u ZT21.Yt , 4. Description of work to be performed PLAW O pDATE An.1D (iJPL�ltrei_f 1N�iLr��'n.n1� �a�{ 5. Value of Contract_ k zmSicob 6. Length of Contract_, , _ 9 — 17, mnsi-r }S 7. Type of Insurance W aiveraso UndApeciex Requested: 000 'DMM 1L-neol (�jl hm%&L LIh0I �) �$ mOD1Tr1GA�Cf�1,>` �51 "[b i`f� �15SD AClyM (a) Limits: (b) Coverage 8. Have you contacted Risk Management to determine if professional liability coverage is available through SCOPE?_ _ Kt> 9. Reason for Request for Waiver or Reduction of Limits 10. Identify the risks to the City if this request for waiver or modifications granted 00 V,&K 6 AVX .. 1 ent Heart Siunarore (This section to be completed by City Anorney) Recommendation: Approve Deny City Attorney's Signature/Date I I 1 Settlement Committee approva es) otof required for this waiver. If Settlement Committee approval is required, submit this form to City Attorne ffice to be placed on the agenda. Recommendation: Approve V Deny City.Council appro [is] [is t required for this waiver. If City Council approval is required, attach this fo to the RCA after considerate y ie 'settlement Committee. This insurance waiver [is not] on City Council agenda. Reviewer's initials: }mp/mi s'inswa iver/3/ l 4/00 RCA kOUTING SHEET INITIATING DEPARTMENT: Public Works SUBJECT: APPROVE AMENDMENT NO.2 TO THE AGREEMENT WITH KENNEDY/JENKS CONSULTANTS, INC. TO UPDATE THE MASTER PLAN OF SEWERS & PREPARE AN INFLOW/INFILTRATION STUDY, CC-1144 COUNCIL MEETING DATE: I Aril 2, 2001 RCA ATTACHMENTS STATUS. Ordinance (w/exhibits & legislative draft if applicable) Not Applicable Resolution (w/exhibits & legislative draft if applicable) Not Applicable Tract Map, Location Map and/or other Exhibits Not Applicable Contract/Agreement (w/exhibits if applicable) (Signed in full by the City Attome Attached Subleases, Third Party Agreements, etc. (Approved as to form by City Attome Not Applicable Certificates of Insurance (Approved by the City Attome) Attached Financial Impact Statement (Unbud et, over $5,000) Not Applicable Bonds If applicable) Not Applicable Staff Report (If applicable) Not Applicable Commission, Board or Committee Report If applicable) Not Applicable Findings/Conditions for Approval and/or Denial Not Applicable �EXPLANATIOWFOR MISSING` A°TTACHMENTS REVIEWED -'.: RETURNED : FORWARDED Administrative Staff Fe Assistant City Administrator Initial City Administrator Initial cam City Clerk EXPLANATION.FOR. .RETURN"OF ITEM';. RCA Author: T. Broussard AMENDMENT NO. I TO AGREEMENT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDY/JENKS CONSULTANTS, INC. FOR A MASTER PLAN OF SEWERS THIS AGREEMENT is made and entered into this Ik-00,day of I#Ai, 1994, by and between the CITY OF HUNTINGTON BEACH, a California municipal corporation, hereinafter referred to as "CITY," and KENNEDY/JENKS CONSULTANTS, INC., a California corporation, hereinafter referred to as CONTRACTOR, WHEREAS CITY and CONTRACTOR are parties to that certain agreement dated October 5, 1992, entitled "AGREEMENT BETWEEN THE CITY OF HUNTINGTON. BEACH AND KENNEDY/JENKS CONSULTANTS, INC., FOR MASTER PLAN OF SEWERS;" and Since the execution of the aforesaid agreement, CITY has requested additional work from CONTRACTOR and CONTRACTOR has agreed to perform such work; and CITY and CONTRACTOR wish to amend the original agreement to reflect the additional work to be performed by CONTRACTOR and the additional compensation to be paid in consideration thereof by CITY to CONTRACTOR. NOW, THEREFORE, it is agreed by CITY and CONTRACTOR as follows: 1. ADDITIONAL WORK CONTRACTOR shall provide to CITY such additional services as described in Page One (1) of CONTRACTOR'S proposal dated January 6, 1994, hereinafter referred to as Exhibit "A," and by this referenced incorporated as though fully set forth herein. 2. ADDITIONAL COMPENSATION In consideration of the additional services to be performed hereunder as described in Section 1 above, CITY agrees to pay CONTRACTOR an additional sum not to exceed Five Thousand and no/100 Dollars ($5,000.00). The additional sum shall be added to the original sum of One Hundred Forty-three Thousand and no/100 Dollars ($143,000.00), for a new total contract amount of One Hundred Forty-eight Thousand and no/100 Dollars ($148,000.00). 41s1Kennedy 1 \03/30/94 Attachrmt 1. REAFFIRMATION Except as specifically modified herein, all other terms and conditions of the original agreement shall remain in full force and effect. IN WITNESS WHEREOF, the parties hereto have caused this agreement to be executed by their authorized officers on the date first above written. CONTRACTOR: KENNEDY/1ENKS CONSULTANTS, INC a California corporation B Donald F. Graf Its Vice President By Blaine L. arrison Its $ecretary REVIEWED AND APPROVED: CITY: CITY OF HUNTINGTON BEACH a California municipal corporation s/s Linda Moulton -Patterson Mayor ATTEST: e-, City Clerk C1Za APPROVED AS TO FORM: '4,9ic IZr'm / '�21 f City Atl6rney INITIATED AND APPROVED: +. • /Director of .Works Attachment: 1. 2 41slKennedy 1 i03130194 n L L J - \pr IL iiS4EDATT: k Qi<:. , .-,--.. -..Ss,,, .. ,... <f.:..-.:�. h;;fk fN•d4s- ..::: - :o-.:dx a. - - <. - -.. ...C. . ONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DEALEY , RENTON & ASSOCIATES [DOESNOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE P.O. BOX 12675 OLICIES BELOW. OAKLAND, CA 94604-2875 COWANIES AFFORDWG COVERAGE ATT: DAVID ECKMAN/FAX 452-2193 510-465-3090 A �CCWAANTT6 DESIGN PROFESSIONALS INS. CO B L�ETT�A ER� ASSOCIATED INDEMNITY CORP. KENNEDY/JENKS CONSULTANTS COMPANY C MARATHON PLAZA, 10TH FLOOR THE MISER CAN INSURANCE CO, 303 SECOND STREET D SAN FRANCISCO, CA 94107 1�T�N COMMERCE & INDUSTRY INS. CO. COMPANY E LETTER ��. � �:.. ...... -• ._ �" 3 '' � ::,: ..::.}::JG.�i. .{�`"02U.. . .- .-....: x.( —..-.�a.,,s.::...:...:t..:..�- -Y:.. ..rc:.5i......' •V'3 iY+sii�S�YaSi�iY�S,r..�:iii:b.A- THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOT WITHST ANDING ANY REOUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCL.MENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAMS. ob L. TYPE OF PiPAANOE POLIOYNUWM POLIOYETTECTIVE POLIOYOWIIAT LIMITS DATE(YMI/OD/W) DATT!(MMI/p01VY) OENERALLIABLFTY GENERAL AGGREGATE f' 2 000 000 X PRODUCTS- COMP/OPAOG. t 2,000,000 D COWERCIAL GENERAL LIABILITY GL 3406311 10/01/94 10/01/95 CiAIMS MADE 7x] OCCUR PERSONAL d AIN. INJURY ( 1.000. 000 EACH CCCURRENCE : 1,000,000 OwN'R-S 6 CONTRACTOR'S PROT. PRE DAMAGE (Ary oee We) $ MED. EXPENSE G one oerco $ AHTOMAOBLE LIABLITY COMBINED SINBLE = C X ANY AUTO MXA 00143204 10/01/94 10/01/95 UMI T 1 000 000 BODILY INJURY ' ALL OwN-0 AUTOS SCHEDULED AUTOS (per penori BODILY INJURY 1 }(l HIRED AUTOS X QN-OWNE7 AU:'S (Pee uciaenU PROPERTY DWAGE i GARAGE JAaILITY LXGESSLIABLITY EACH OCCURRENCE UMBRELLA FORM AGGREGATE Ir -- - - OTHER THAN UMBRELLA FOFM WORCER'e DOMPbMATION X STATUTORY UMITS EACH ACCIDENT 1,00000 B WC 80661126 1/01/95 1/01/96 AM DISEASE -POLICY LIMIT 1 DOD 000 EWILOYEWLIABLITY DISEASE -EACH EMPLOYEE OTHER A PROFESSIONAL RPL700043 9/15/94 9/15/95 $1,000,000 PER LIABILITY CLAIM AND ANNUAL AGGREGATE D[SANPTION or OPEAATwakoCATIONwfWHW_Ef $MiAL nEMi ALL OPERATIONS OF THE NAMED INSURED. General Liability Endorsement Attached. CfRTIFICAT HOL33EFE, 4 k ` #, 0M s gC,hIECEEI.IIiiOH SHOULD ANY OF THE ABOVE CFSCRIBEp POLICES BE CANCELLED 9E=QRE THE EXPIRATION DATE THEREOF. THE ISSUING COMPANY W'.LL ENDEAVOR TO . MAIL 30 DAYSWRITTENNOTICE '+OTHECERTIFICATEHOLCERNAMEDTOTHE City of Huntington Beach LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR Attn: Steve Kreiger LIABILITY OF ANY KD140UPON THE CGMPANY,ITS AGEENTSORREPRESENTATIvES. 2000 Main Street :: AUTHoq[iEDREAAESEN7ATN 1 P.O. Box 190 RNTO & 28560000 Huntington Beach, CA 92040 BY >»SY �, .�fkt,.ks _t _ �} } pry {�i..y�y� 2t t /�, �RifyRP�/.-RA�70?;'C.99si'.• ...::..}--,.}y }}-4 .r� -A: ?P 3 $ ..w};.24- M..K#'? k-- :} ..;�K4V A2+ [iff� CITY OF HUNTINGTON BEACH INTER -DEPARTMENT COMMUNICATION HUMIrGTON REACH TO: Steve May, Principal Engineer FROM: Evelyn Schubert, Deputy City Clerk SUBJECT: Kennedy Jenks Consultants, Inc. DATE: February 1, 1995 " The City still does not have an executed agreement for Kennedy Jenks Consultants because the insurance certificates have not been provided to the City as is required under the terms of the agreement. This contract was approved May 18, 1994. 1 talked with you twice in May and once in October and was assured the Certificates of Insurance would be forthcoming. g:Cel�ite\May - _ r + }� F� 3sr f .T,-�"o;frf_�' .•'y $• 4� a 1 J F q,,, - <, F' 'L .'' �i+T,, . i �1. �!-� 9. f_ - 1 , i'- .f� [• -. ,y �,� ,.° ti - • }, ! qLS J ' J - 1l . - - r• ' '•� C,,,• q3,- _ -.'� !• }, T . ' 3 i • '?; �,•' • o - � • � o r' ., _' � �ry �� F > "µ• -'�- 4, Sq } •�tf - �Y 1 Jr'y. t - ;`_'_ ., i � �r'� 1r �' �, wF;.� ,P --! + !' l - _ f- !'^ �: F •y$ ' 1!-. rFFjritli _rY-. n i _ _7 } - }w.4� y #-• �_ r. _ 4, J. Y - .. ; - j:. 4 .+' r - i J - r - - ''r c''•_ Y r!t�' ?... 4 'ems . � . p - 1 '- - _ `�. � � - _,�-r4-",.., , -Fri r ; _J- � .{ ��[�•. ����1' �' q'- :f--� - .��-�- - •!�/f Yam`-{�® ..�`_-'�-fi {r. .r: ;�. - r.- - •"` �` -. `'-r`•ti: `'y-,r� "-" -- collng-147. Jll�P}r'- •f"€([..y, fA C �!l/F���1 � ,,. i• r ' ��, ` is �_ k r Ab IN-V• +-�� •,. _ �,�-_ tJn �t } t _ r' , S 1. e .k�!i+ -` ,i . �S _ j ;, s .7' � ..._...._.., -..-. .._._.. --�,.,�.'-....�.u.a-,..•� •,- r �� a {f` +Z` �� . S , _,` ..� 5-n" � i- ,3A �Gr �� -�;��� �� ,w - -- � . __ _..w-•—.-.+_ _ _ _ .mart•' ; � r.,i� u mil_ ni ti�A �u is R• -Qu FO - •-{ - 'Cy '� A ii r�� , r �, r f /y ''R.r1�r'¢r Y.- ! __ �..l� -'! a , .A�['r"��•�,+,�i45 ''-e-'�C- i.~ y_ _ -_�� li _ .- 'W". ly3naL�1 I1 tin114�7Yi+[+~ttG�� f 4 4 •i_`3•J,b•U+-�Sf-- .. .Il a', ]-r- I•Tiv -YiJ _ � � y r., G p•rw-w.wi..y qCk'`%• -,_ .rw�•,w - x} �w s �_ �_ �y�, k a,--sue•-`.i{g7; - �'• ?"r`sc •r - - ilJ 7i -aA - {+x .. [-•'�3J y- ''I rani :r� `- -�JSo'� `;,-'"r"'�.',T..-�5`k+ w ft4.4q. ! 'w•l+a'';+!'i�.. wr 7; �'t -r- ,v: r l_' e _ ri (ryw-Y s' 4-.1 F - _ .•); tyy­. �, //?��F { //J� /�I � �� ``"^`x ,�. -c. ir.�'� aar� - ��'�" %`4 ._".r" w'.�! :�:v�:^•i�• "'`L`� � K � , r . V r? I.�..r �.i.1/F'. R� � '�� �,_ �, •�-1 J� ` :z •� _. .9•-'{�'liFaT� L.,. •r,. ,y_. �r;J�•4 rf '�iy3<�+ i� o- �a. < .•u A yam,- +a F {,y�._.(.r1+7•y',, i+".,b..` a`W{k �'i?• rf r•,. �i' ' r] -'fir {'_ .4 r,,_� AI', �}�'.4`�i`��,/ , (J /s.�y ..� +�1 ,a ,•fa •i , ' ,- �, •r Y.'�! ��i �' C x,r �! {,(/i/{./:'f/f�tis- T Sl r .fSr-- _ �..��~ 'l 1 ' - , �'t�",aF� Sr- -�' ! i �r __ �. �` ArJ'� y// • �. 5 _ _ ��m_ -v � �u�.� � ti � - rx v jj�/// •f r r` � 4^..:.. f+i �. i -e`•�= `�� 'LIa; /.rioat •wr.•4r -4 vc 9yiae•.or.r-.�-�rQ�_- �..rY «..�:-.• �..}"..'^'t .={'f •;��.i� �S'N`i ' ,. C� � � � //''�'' ��] ��(/_� /}�•�• _ �] , ." Ali Y: �__ f-.l G � q� �S '��j �,1p��+� j� ! M V vY { .. 1t ..U..1 •} ,�r •T..� :_O i!'w'. [� - - •IF �iij ii. _-lh�T'[T' -.r. �•,,�� - 11, ita .....r. r,4,rir!. = _ i/// -. - •.. - - - - . +r.w.r+arl. r,. ' Y p.• i'1, +} _ - t1it•,.. I Om }'•'l�. '{^".. ('`"_-""�.'�-"'- --`- - -- +ar _.,,r.r�a--_-,�.c-.e.v _ J. - + A ,Y•-'' j�`�A� •6ir�_� i _ 'r#"`.,.'.--�'-v-__�..'7- „��„ f "-•y ....,�.s„�.cn,� e"+r7r".c.wn", - �:: •_ ,� . +_ „'r�. ;l,E ° NLrp ci 4� f� { '� - � ,+}l." -� T' w ; �L�' __' r•, �*I '.,1 - � � ,,: S, �,•ni � t, - -�-t �'•- 9 n - �i `r' � � "' " 1 r L'viJ Ji.1. r rl .irtil�w ;ti •._ : w,Jr .► a "" v w , 1� h [j .fgU�,} 4c .1" r5 ..., t T .,{J }, fG - .^�^,w,^•?^y��+R'!r P-�,L- q�- ., •tb ,f'tia'�.f ' � _, v:7. i r: ,I,. ,* ' i � - ,+` a LF a •�� Fv - .. 9 • ,1,. -•j .. �:� �• - '- �- ' „�.�s S' - ,k r •i �iy i• +n � • � l5' '_ , ..� - - - .• 9'a"'••-"�"'Y�"�r'F'I'r�-....+r•.r• } - - i _ bl � � + -$�� 1 L `� -_ r'' J-�:� 1 � y� : � .,�'.�r'�� 'I; .4 � +� .- - "i • >` •:-•a. `, .. - - •.f. -� < - ¢i ~ u'r�• '`Z�� zK CITY OF. HUNTINGTON BEACH INTERDEPARTMENTAL COiMMUNICATION TO: Jennifer McGrath, Deputy City Attorney FROM: Linda Daily, Public Works SUBJECT: Completion of Outstanding Approved Agenda Items DATE: December 18, 1997 1) Kenned.y Jenks Consultant- Amendment to the Master Plan .of�ewers greement Dated The contract was not executed by the Mayor and Clerk because current Certificates of Insurance were not obtained. The terms of the contract were fulfilled and full payment was made. Kennedy -Jenks is a reputable professional engineering corporation that continues to provide services for the Public Works Department. Their insurance was valid in 1992, and has be current on other proposals and contracts. We have no reason to Relieve the insurance lapsed during the term of the 1994 contract. Since this was an advisory document, the Public Works Department requests that the insurance requirement pertaining to this contract be waived. 2) Contract for Mushroom Farm Sit@ Grading -Roadway Construction Co..lnc, Dated A ri, 1993. The contract was not executed by the Mayor and Clerk because Certificates of Insurance were not obtained. Due to the age of the document, the Public Works Department cannot determine why these items were not received or the issue pursued, The terms of the contract were fulfilled and full payment was made. As this was a grading project, inspected by the Public Works Department, we have no reason to believe that there is potential for any actions by Roadway Construction, or the City. Please waive the required documentation so that the item may be resolved. I have discussed this action with the City Clerk, and she is in agreement Please call me at extension 5599 if you have any questions. Thank you. Attachments: City Clerks Office Completion requests (2) RCACU.DOC u �• 0 City of Huntington Beach P-O. BOX 190 CALIFORNIA VaGM FROM THE DESK OF RAY SILVER Assistant City Administrator 0 0 HUNTINGTON BEACH From the desk of- City of Huntington Beach P. 0. Box 190 - 2000 Main Street Huntington Beach, California 92648 Connie Brockway, CMC City Clerk Telephone: (714) 536-5404 Fax: (714) 374-1557 71z�- A e -A DATE: //-,�6 -9 7 TO: " ,� ,-,- �f�j1./Il �+ to ftfL FROM: Connie Brockway, City Clerk The above item Can be officially filed if� the following requirements are met: �e /?a t n eA C� rl D 7Y' t71N1 D P w 'L. C I T-� /T i r ✓NR / Yl e'- 7 7c Al bw — — —(A , 5 w o s )n-e u-R^ S i �r",j �'I f 1 y/ o ✓� f�'�� b-ecaus bPw AJ not kA-uc 11-g- VAS -)P14A-e P)-e"s-e �A-Ue.. C4 H1 ft- CID we- rr ie GLw�,V L)nSPD � 'T-S �� hA'fT r-ee « 'i'o 1c no-J, 637 In order for the City Clerk's Offic to proceed, please check (r/) as applicable: le- CJ-1 v acte� � our ( ) The necessary requirements will be provided by�e �Q Date OR (Y) Completion of this item is no longer necessary uj.p wvh Ct b 1 e fu Ct?n n -e At r wa T Department Head Signature _ City Attorney zh0--, D puty ity Attobh cc: City Attorney City Administrator lJ DATE: TO; , FROM: Connie Brockway, City Clerk suBJECT .. COMPLETIONBY:YOUR;DEPARTMENT OF CITY COUNCIL APPROVED. AGENDA ITEM'—':,... -- ::. f ITEM: /.1�/LXll%► - 1 U v Date Approved: The above item can be officially filed if the following requirements are met: In order for the City Clerk's Office to proceed, please check (,/) as applicable: ( } The necessary requirements will be provided by Date OR { ) Completion of this item is no longer necessary. Department Head Signature cc: City Attorney City Administrator City Attorney Deputy City Attorney i- ,11� - - �7 r �Y/9- DATE: TO: FROM: Connie Brockway, City Clerk :.: :.. :. :SUBJECT COMPLFTI.ON BY YOUR DEPARTMENT. OF CITY COUNCIL APPROVED AGENDA.:ITEM ITEM: kfAjAjrsn'7 - SLrn�kS Ceti.so 1 N ftfs —A,154- 00/0,,l Date Approved: R E C E I V JE The above item can be officially filed if the following requirements are nIMPT• of PURL-1c WDR K_ OCT 2,7 1997 IiUNTINGTO,V BEA H, C In order for the City Clerk's Office to proceed, please check (,/) as applicable: { ) The necessary requirements will be provided by Date OR ( ompletion of this item is no longer necessary. Department Head Signature City Attorney cx�2L deputy City Attcoey cc: City Attorney City Administrator 4' i3- 97 RAY, �1e4�s r Q S 0v%d - T$% P a'k o�• -JIB Cis CITY OF HUNTINGTON BEACH 1117, INTERDEPARTMENTAL COMMUNICATION HUNTINGTON BEACH TO: Ray Silver Assistant City Administrator FROM: Connie Brockway C0 City Clerk DATE: September 2, 1997 SUBJECT: KENNEDY JENKS CONSULTANTS --MASTER PLAN OF SEWERS ORIGINAL AGREEMENT --ATTACHED During the agenda process meeting you attended, the backlog of agreements was discussed. This is an agreement for which the Clerk's Office could not obtain the approved insurance certificate and could not affix the Mayor's signature until Public Works, who was to get the insurance from the contractor, was able to get it. As the job is probably complete and paid, it would be appreciated if Administration and the City Attorney's Office would complete the attached yellow completion sheet. The Clerk's Office does need to know if the contract should be signed by the Mayor and Clerk even though there is no insurance in the file to cover the agreement. (If the Public Works Department could get a copy of what the company had in force, it would help even if it did not meet requirements --it would show there was insurance in force at the time.) This is an agreement for which Steve May, Public Works Department, was to obtain insurance. He is no longer here as you know. I have others on which I will be requesting your assistance, but this is a start. Thank you. Attachments: Original Amendment No. 1 To Agreement Between The City of Huntington Beach And Kennedy/Jenks Consultants, Inc. For A Master Plan Of Sewers New Form For Departments To Obtain Insurance cbmemos/97-096cg J � HUNTINOTON BEACH TO: FROM: DATE: i CITY OF HUNTINGTON BEACH INTERDEPARTMENTAL COMMUNICATION �` ✓ Ray Silver Assistant City Administrator Connie Brockway Co City Clerk September 2, 1997 rt+ , 1 timwork6o SEP p5199� NcTOr4 E3�GH. l-Avr4-rx SUBJECT: KENNEDY JENKS CONSULTANTS --MASTER PLAN OF SEWERS ORIGINAL AGREEMENT --ATTACHED During the agenda process meeting you attended, the backlog of agreements was discussed. This is an agreement for which the Clerk's Office could not obtain the approved insurance certificate and could not affix the Mayor's signature until Public Works, who was,to get the insurance from the contractor, was able to get it. As the job is probably complete and paid, it would be appreciated if Administration and the City Attorney's Office would complete the attached yellow completion sheet. The Clerk's Office does need to know if the contract should be signed by the Mayor and Clerk even though there is no insurance in the file to cover the agreement. (If the Public Works Department could get a copy of what the company had in force, it would help even if it did not meet requirements --it would show there was insurance in force at the time.) This is an agreement for which Steve May, Public Works Department, was to obtain insurance. He is no longer here as you know. I have others on which I will be requesting your assistance, but this is a start. Thank you. Attachments: Original Amendment No. 1 To Agreement Between The City of Huntington Beach And Kennedy/Jenks Consultants, Inc. For A Master Plan Of Sewers New Form For Departments To Obtain Insurance cbmemosl97-096cg i • .11 JJAT HUNTINGTON BEACH From the desk of- /i 6,-'?7 City of Huntington Beach P. O. Box 190 - 2000 Main Street Huntington Beach, California 92648 Connie Brockway, CMC City Clerk Telephone: (714) 536-5404 Fax: (714) 374-1557 !��3 ry+G T�cl�� G"r1�S.o�c.l[Y7i117 r rr I DATE: TO: FROM: Connie Brockway, City Clerk suB�ECT...: COMP: LETION K.Y...OUR DEPARTMENT OF CITY..: COUNCIL APPROVED AGENDA ITEM ITEM: Date Approved: The above item can be officially filed if the following requirements are met: In order for the City Clerk's Office to proceed, please check (,/) as applicable: ( } The necessary requirements will be provided by Date OR Completion of this item is no longer necessary. Department Head Signature City Attorney �WP' D�ty City Attorn cc: City Attorney City Administrator FB CITY OF HUNTINGTON BEACH `I INTER -DEPARTMENT COMMUNICATION rurmtieson SEACH TO: Steve May, Principal Engineer n FROM: Evelyn Schubert, Deputy City Clerk "SUBJECT: Kennedy Jenks Consultants, Inc. DATE: February 1, 1995 The City still does not have an executed agreement for Kennedy Jenks Consultants because the insurance certificates have not been provided to the City as is required under the terms of the agreement. , This contract was approved May 18, 1994. 1 talked with you twice in May and once in October and was assured the Certificates of Insurance would be forthcoming. e9v .l_�P— 1e,111 3 &iamcn�tensy REQUEST FOR CITY COUNCIL ACTION Date: May 16, 1994 Submitted to: Honorable Mayor and City Council AppRpV.. NC;IL Submitted by: Michael T. Uberuaga, City Administrator Prepared by: Louis F. Sandoval, Director of Public Works c cz x Subject: A JE ME TO CONTRACT WITH KENNEDY JENK C NSULT C FOR RE OF THE BOLSA CHICA DRAFT EIR ,�j� %Ajr - - Gy a -All Consistent with Council Policy? {X] Yes ,,, L a �,�, �� Y 13' � ��t...�, p w ----------------------- -- �''-.c.4�—�------------------� Statement of Issue, Recommended Action,' Analysis, Environmental ource, Alternative Action, Attachments: -'t ` - --------'-''-`-e -----------------JZ&P- -------- 4 dot STATEMENT.OF_ ISSUE: It is requested that the existing contract with Kennedy Jenks Consultants, Inc. for preparation of the City's Sewer Master Plan be amended to provide for assistance to staff, by Kennedy Jenks Consultants, Inc., in the review of the Bolsa Chica Draft Environmental Impact Report. RECOMMENDED ACTION: 1. Approve an amendment to the current year budget by appropriating $5,000 for consultant services to assist staff in the review of the Bolsa Chica Draft Environmental Impact Report; AND, 2. Approve the attached contract amendment with the firm of Kennedy Jenks Consultants, Inc. to assist staff in the review of the Bolsa Chica Draft Environmental Impact Report. ANALYSIS: The City Council had previously directed that staff conduct a thorough review of the Bolsa Chica Draft Environmental Impact Report (BCDEIR). The current work load assigned to Public Works Staff did not allow for a thorough review of the sanitary sewer elements of the BCDEIR within the short time available, Therefore, consultant services were used to assist staff in completing the review of the sanitary sewer element of the BCDEIR. Kennedy Jenks Consultants, Inc. is presently working on the City's Sewer Master Plan; They are very familiar with the City's sanitary sewer systems, and they are highly qualified to review the sanitary sewer aspects of the BCDEIR. R REQUEST FOR CITY COUNCIL ACTION Date: May 16, 1994 Submitted to: Honorable Mayor and City Council APPROV':. Submitted by: Michael T. Uberuaga, City Administrator l ^� 19 Prepared by: Louis F. Sandoval, Director of Public Works 00i,C CLLAK ,Jice Subject: AMENDMENT TO CONTRACT WITH _. KENNEDY JENKS CONSULTANTS, INC. FOR REVIEW OF THE BOLSA CHICA DRAFT EIR Consistent with Council Policy? [XI Yes Statement of Issue, Recommended Action, Analysis, Environmental Status, Funding Source, Alternative Action, Attachments: TATEM NT OF ISSUE: It_is requested that the existing contract with Kennedy Jenks Consultants, Inc. for preparation of the City's Sewer Master Plan be amended to provide for assistance to staff, by Kennedy Jenks Consultants, Inc., in the review of the Bolsa Chica Draft Environmental Impact Report. RECOMMENDED ACTION: 1. Approve an amendment to the current year budget by appropriating $5,000 for consultant services to assist staff in the review of the Bolsa Chica Draft Environmental Impact Report; AND, 2. Approve the attached contract amendment with the firm of Kennedy Jenks Consultants, Inc. to assist staff in the review of the Bolsa Chica. Draft Environmental Impact Report. ANALYSIS: The City Council had previously directed that staff conduct a thorough review of the Bolsa Chica Draft Environmental Impact Report (BCDEIR). The current work load assigned to Public Works Staff did not allow for a thorough review of the sanitary sewer elements of the BCDEIR within the short time available. Therefore, consultant services were used to assist staff in completing the review of the sanitary sewer element of the BCDEIR. Kennedy Jenks Consultants, Inc. is presently working on the City's Sewer Master Plan; They are very familiar with the City's sanitary sewer systems, and they are highly qualified to review the sanitary sewer aspects of the BCDEIR. } Request for City Council Action Amendment to Contract with Kennedy Jenks Consultants, Inc. May 16, 1994 Page 2 Kennedy Jenks Consultants, Inc. completed their review of the BCDEIR, and their comments were included with the staff report to the City Council Committee on the BCDEIR. The attached contract amendment would allow for payment to Kennedy Jenks Consultants, Inc. for work already completed by them in reviewing the BCDEIR. EWIRONMENTAL STATUS: The recommended action is not a "project" as defined in Cal. Gov. Code. Section 15378, and is not subject to provisions of CEQA. FUNDING SOURCE: Funds are available in the unreserved, undesignated General Fund. This item is not budgeted. ALTERNATIVE ACTION: Deny the recommended action. If the recommended action is denied, then payment to Kennedy Jenks will be made under the existing contract by eliminating portions of the scope of work necessary to complete the City's sewer master plan. ATTACHMENTS: 1. Amendment No. 1 to the contract between the City of Huntington Beach and Kennedy Jenks Consultants, Inc. for review of the Bolsa Chica Draft Environmental Impact Report. LFS:REE:SWM:swm REQUE 7 FOR CITY COUNCIL ACTION Date: October 5, 1992 Submitted to: Honorable Mayor and City Council Submitted by: Michael T. Uberuaga, City Administrator Prepared by: aA ouis F. Sandoval, Director of Public Works Subject: NEW MASTER PLAN OF SEWERS Consistent with Council Policy? [X] Yes APPROVED BY CITY COUNCIL y- I CITY CLI ' ------------------------------------------------------------------------------ Statement of Issue, Recommendation, Analysis, Funding Source, Alternative action, Attachments: -----_------------- ------ STATEMENT OF ISSUE: The City's Master Plan of Sewers requires updating to identify areas of system deterioration and to address changes in law, design criteria, land use and funding mechanisms. RECONDAENDATION: 1. Authorize staff to reappropriate $100,000 from the unappropriated sewer fund balance to cover the total costs of preparing a new Master Plan of Sewers, and 2. Approve the attached agreement with Kennedy Jenks Consultants, Inc and authorize the Director of Public Works to expend $150,000 to cover contract costs of $1431,000, anticipated change orders of $5,000 and supplemental expenditures of $2,000. ANALYSIS: Introduction: The City's current Master Plan of Sewers was prepared by Lowry and Associates in 1979. Since that time there has been system deterioration and changes in legislation, design criteria, .land uses. and funding mechanisms. A new master plan of sewers is needed to adequately plan future sewer system improvements, and to fairly assess sewer connection fees and user fees. Consultant Services Justification: It is proposed that an outside consultant be used to prepare the master plan. Following is justification for this proposal. 1. Major components of the master plan are beyond the expertise or manpower capabilities of City staff. And, the computer modeling r and analysis can not be achieved with computer assets available to 1J ' t Request for City Counci Action New Master Plan of Sewers October 5, 1992 Page 2 City staff. The master plan must be completed within a one year period so that it is not obsolete by the time it is completed. The labor hours involved would require six staff members, at half time, for one year; these staff people are not available. Legal and engineering expertise in the field of cost allocation is required and is not available among current staff. The following, general scope of work identifies which tasks can not be performed by City staff: a. Task No. 1; Research and investigation to evaluate existing data and to observe field conditions. Current staffing does not allow for the time required to complete this task. However, an intern was hired in August, 1992 to begin researching City records and accumulating data. This in --house research effort does not require special expertise, and will be completed by the intern at one third the cost of consultant services. The proposed consultant contract already accounts for portions of this work to be completed by City staff. b. Task No. 2; Develop design criteria and product specifications to conform with the City's needs, current law, and the future geographic information system (GIS). The expertise of one dedicated to this field of engineering and law is required. C. Task No. 3; Develop a computer model of existing and future sewer systems. Computer programming expertise required is not available among City staff. d. Task No. 4: Analyze existing and future systems. Personnel required to complete this task are not available among City staff. e. Task No. 5: Prepare cost estimates for future improvements. Manpower required to complete this task is not available among City staff. f. Task No. 6; Prepare a cost allocation program for system maintenance, upgrade and expansion. This program will identify user costs and may be used as a basis of future fee programs. The expertise of one dedicated to this field of law is required. g. Task No. 7; Prepare a comprehensive, draft, master plan report and user's manual. Personnel and expertise required to complete this task are not available among City staff. h. Task No. 8; Prepare a comprehensive, final, master plan report and user's manual. Personnel and expertise required to complete this task are not available among City staff. i. Task No. 9: - Provide project management. Professional responsibility requires that this task be done by the consultant responsible for the master plan. Request for City New Master Plan October 5, 1992 Page 3 CounciVAction • of Sewers J. Task No. 10; Conduct training program to train City staff on use and maintenance of the master plan. This task must be done by the consultant who prepares the master plan. The cost of this effort has been minimized by limiting the number of staff to be trained. Additional training, as necessary, will be by City staff. k. Task No. 11; Conduct meetings for City staff, community groups, and City Council, as necessary. City staff will perform as much of this task as possible, within limitations of personnel and expertise. 2. Additional staff could be hired to complete the master plan in- house, in lieu of contracting with a consultant. The need for legal and engineering responsibility for the completed work product would require that the entire team of experts and manpower be brought under control of City staff. It is obvious that the hiring effort and indoctrination costs would not be justified for a short term project of one year duration. Present market conditions have allowed City staff to obtain proposals for professional services which appear to be minimally profitable for the proposers, and which will cost the City much less than hiring the necessary expertise and Personnel. Proposal Evaluation and Recommendation: On May 11, 1992 requests for proposals engineering consultants. Each firm was response by June 8, 1992. Proposals were four firms: Firm 1. Boyle Engineering 2. Kennedy Jenks Consultants 3. BSI Consultants 4. Tait & Associates were mailed to 11 qualified asked to submit a written received from the following Location Newport Beach, CA Irvine, CA Santa Ana, CA Orange, CA On June 23, 1992 a four member committee met and Iprepared written evaluations of each proposal on the basis of qualifications and experience of key individuals, staff availability, references, successful completion of similar projects, and quality of proposal. Boyle Engineering and Kennedy Jenks Consultants received the highest scores and were interviewed on June 29, 1992. The committee then, unanimously selected Kennedy Jenks Consultants. Boyle Engineering submitted an excellent proposal and made a very professional presentation, however the proposed scope of work as presented by Kennedy Jenks Consultants was less extensive and is better suited to the needs of the City and with budget limitations. Therefore, the Director of Public Works recommends the attached agreement with Kennedy Jenks Consultants, Inc. be approved with the following provisions: Request for New Master October 5, Page 4 City CouncipAction • Plan of Sewers 1992 Agreement amount: $143,000 Anticipated change orders: $ 5,000* Supplemental expenditures: $ 2,000** TOTAL = $150,000 * The Director of Public Works is requesting authorization to spend up to $ 5,000 for anticipated change orders which can not be specifically identified or precisely defined until investigation and analysis phases of the work are completed. ** Completion of the master plan could require some field testing, reproduction or other expenses. Therefore, the Director of Public Works is requesting that $ 2,000 be encumbered for supplemental expenditures. Budget: The approved City budget for 1991/92 included $100,000 for phase one of the Master Plan of Sewers, and the approved budget for 1992/93 includes $50,000 for phase II. The above scope of work includes both phase I and phase II, and the proposed fee is within the estimated budget of $150,000 for both phases. The $100,000 appropriated in 1991/92 was not carried over to 1992/93. Therefore, the Director of Public Works is requesting that $100,000 be reappropriated from the unappropriated sewer fund. FUNDING SOURCE: $100,000 is available in the unappropriated sewer fund balance (Account No. G-SL-00-000-3-01-01). $ 50,000 is available in expenditure account E-SL-PC-838-3-90-00. ALTERNATIVE ACTION: Deny approval of the agreement the unappropriated sewer fund, Plan of Sewers. Sewer connection of development projects may not may be subject to challenge. ATTTACIZ=S: and proposed transfer of $100,000 from and forego development of a new Master fees currently collected with approval be in compliance with current law and 1. Kennedy Jenks Consultants, Inc. agreement. 2. Fiscal Impact Study. LFS:REE:SWM: RCA. 03 • • H CITY OF HUNTINGTON BEACH INTER -DEPARTMENT COMMUNICATION HUNTINCTON BEACH TO: MICHAEL T. UBERUAGA, City Administrator FROM: ROBERT J. FRANZ, Deputy City Administrator SUBJECT: REQUESTED APPROPRIATION FOR DEVELOPMENT OF NEW MASTER PLAN OF SEWERS, FIS 93-17 DATE: SEPTEMBER 17, 1992 As required by Resolution 4832, a Fiscal Impact Statement has been prepared for the proposed appropriation of $150,000 to accommodate an update of the City's Master Plan of Sewers. Sufficient funds are available in the Sewer Funds Contractual Services Account to accommodate approximately $50,000 of the anticipated expense. Upon approval of the City Council, the remaining $100,000 would be derived th ugh accessing undesignated, unreserved, unaudited Sewer Fund mo ies, thereb educing the balance of these funds to $3,552,000. ' ROBERT J. j Deputy ty Aq inistra RJF:skd WPADSERT:111O ::-�-�t.... r;M1.v : r�,•i: i#;g:g�>'u }•''tr"��"":�+� � (YY/ ..s �/ E2 S i:�Y,�k';i. «?6Y.t:' rl,}::o .<;.:n..s.::$i TSSNED TE .gi °t..:.,icrtycr k`.ri V: :.:tr,'",:.:;. -j;>y'x. Sb:L.k r{,{{ ;{}�;i{.. ay, r•^•�- :wawwo..o:avai�: :;:<6 o.tiiCLJw}f,"; ,lr M..Y''v':t.'u, THIS CIERTIFICAlk 13 133UhU AS A MATTER OF INFORMATION ONLY ANU CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DEALEY, RENTON dl ASSOC. DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE P.O. Box 12675 POLICIES BELOW. COMPANIES AFFORDING COVERAGE Oakland, CA 94604-2675 ATTN: DAVID ECKMAN COMPANY A 510-465--3090 Security Ins. Co. of a o d COMPANY LETTER B A oeiated ndemni Co Rlupm COPANY C Kennedy/Jenks Consultants Marathon Plaza, 10th Floor American Insurance Co COMPANY D 303 Second Street Son Francisco, CA 94107 LETTER Scottsdale Ins, Co COMPANY E LETTER _,.-:,.>sc�w...,,w�wwa�;.�s.,av ..,.._.. :r::r::;..:: }}.: �: 1� �o-::: :.r �:.,. ..ac•,r:r.:?,...xt ;;t•:,: S... ,.:...:. THIS IS TO CERTIFY THAT THE POLICIES OFINSURANCELISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIO[) INDICATED. NOTWITHSTANDING ANY REOUIREMENT, TERvT OR CONDITIONOF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWNMAY HAVE BEENREDUCED BY PAID CLAMS. CO LT TYPEOFINSURANCE POLIOVNUNIQF POLIOYFJFEOTNE POLIOVEXPIRATICA LIMITS DAT!(YY/DD/YY) pATE(YY/Op/YY) CIENERALL1ABLTfY GENERAL AGGREGATE t 1 000 000 PRODUCTS-COMP/OP ADO. INCLUDED D COMMERCIAL GENERAL LIABILITY RENWAL OF AES000252 10/01/02 10/01/93 CLAIMS MADE a] OCCUR. COMPREHENSIVE GENERAL PERSONAL 6 ADY. INJURY =INCLUDED EACH OCCURRENCE t .000.000 OWNER'S A CONTRACTOR'S PROT. LIABILITY FORM FIRE DAMAGE (Aone fire) _ IVIED. EXPENSE U one ersa = AVTOMODLa LIADLrrY COMBINED SINGLE C X ANY AUTO RENEWAL OF 10/01/92 10/01/93 LIMIT 000 000 BODILY INJURY i ALL OWNED AUTOS SCHEDULED AUTOS MXA80105526' (Per person) BODILY INJURY 1 X HIRED AUTOS �•-, PF l'r n`,[ i_.. __ _ Y X NON OWNED AUTOS - �' (Per accid[n11 �'_I.`c GARAGE LIABILITY .- PROPERTY DAMAGE ; B EACH OCCURRENCE AGGREGATE TLIJBIFIELLIABLFTY A FORM M� EA THAN UMBRELLA FORM WORKER'S OOM PO4ATION X STATUTORY LIMITS .................... EACH ACCIDENT t 1.000.0.00 B AM WP00490028 1/01/91 1/01/94 DISEASE —POLICY LIMIT 1 A.000 000 F f�LOVEIIS"LIAO�RY DISEASE—EALH EMPLOYEE OTHER A PROFESSIONAL RPL489957 9/15/92 9/15/93 $1,000,000 PER LIABILITY CLAIM AND ANNUAL DESCRIPTION OF OPMATIOKWLOOATIONSIVOIIOLES1kPE01AL F1EMS ALL OPERATIONS OF THE NAMED INSURED. General Liability End't Attached -c}-:s.:;.:: ::hii^: •: - - - - - .Y-i.".%Yx G:4:':{.::ti.i:G:4':.G:h' 8. :0:�2�<). i.,f.{%:r%c.{r :•xr: 4 £.. ::a:d:hr.'•>a}.s::i::a:•::dY.:.»::.}:sr:Y.Y.>isa�.:::•::�}::�}:a:�:��:}:ir.:.:,::-._:-:.: :..�:: _ - �{•#��{?f-}:•6..: r#S-.. si��J?n:�:-: G.-.sa:....(�: f: �. t.....:.v:{{.,_;i�ii:v:.•%•#::4%G:}:G::u.-.-:..�r.,..ienv.v::.vnv.:v::4�:.:v.v::::..v:.vi:?�.i::::�:.v::.v.v..-::.z�n�: l..:.:?� �Y:.i�: nvhv..:s:v. �.-0:•}:..ra:ti:L�"if'�:ivy:.U:.�pn'�f.:{nS:O:S:G.'C.4'iiv'R�S�.itikv.w{vtvntiti�rc�{.�i�:�ni�n�fti':�.:- ^Y.{•r.J.�:4:tvv�:5{vn :.$n:i::• SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 30 DAYSWRITTENNOTICETOTHECERTIFICATEHOLDERNAMEDTOTHE City of Huntington Beach r LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR Attn: Steve Kreiger LIABILITYOFANYKINDUPONTHECOMPANY. ITS AGENTS ORREPRESENT ATIVES. 2000 Main Street ` G:= AurHaT®TATFVE DEAL Y, RENTON P.Q. Box 190JC1285600D0 Huntington Beach CA 92049 BY v.: f' ::i::: s:? - - . I.SF.��.}:- �I�T' :..-:::...-. r.::r...:: �:':: ::: :;:.�:::.. - .--.. .�::. �: ': �: �:�: ;:#;:!s:;:. �. .�M 1!S��I��•i4M1 . �:...... ...... ........t :.nh:ri::?.h;:.::�-.-„i.:..:?: jr ti• In consideration of an additional premium, it is hereby understood and agreed that the following applies: Additional Insured The City of Huntington Beach its officers and employees is/are Additional Insuredls as respects work done by Named Insured. Primary Coverage With respect to claims arising out of the. operations of the Named Insured, such insurance as afforded by this policy is primary and is not additional to or contributing with any other insurance carried by or for the benefit of the above Additional Instired/s. Cross Liability Clause The naming of more than one person, firm or corporation as insureds under this policy shall not, for that reason alone, extinguish any rights of the insured against another, but this endosement, and the naming of multiple insureds, shall not increase the total liability of the Company under this policy. Notice of Cancellation It is understood and agreed that in the event of cancellation of the Policy for any reason other than non-payment of premium; 30 days written notice will be sent to the certificate holder by mail. In the event the policy is cancelled for non-payment of premium, 10 days written notice will be sent to the above. Policy No.: Renewal of AES000252 Effective Data, 10/1/92 Insurance Company: Scottsdale Insurance Company Issued to: Kennedy/Jenks Consultants, Inc. DEAI Y, RENTON 8 AAOCIATES Authorized Representative: BY �L � • 0- CITY OF HUNTINGTON BEACH 2000 MAIN STREET OFFICE OF THE CITY CLERK CONNIE BROCKWAY CITY CLERK October 21, 1992 Kennedy -Jenks Consultants 17310 Red Hill Avenue, Suite 220 Irvine, CA 92714 CALIFORNIA 92648 The City Council of the City of Huntington Beach at the regular meeting held October 5, 1992 approved an Agreement between the City of Huntington Beach and Kennedy Jenks Consultants, Inc., for a Master Plan of Sewers. Enclosed is an executed copy of the agreement for your records. Connie Brockway City Clerk CB:bt Enc. i Telephone: 714.536.5227 ) r AGREEMENT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDY JENKS CONSULTANTS, INC. FOR A MASTER PLAN OF SEWERS TABLE OF CONTENTS PAGE 1. WORK STATEMENT . . . . . . . . . . . . . . . . . . . . 1 2. CITY STAFF ASSISTANCE . . . . . . . . . . . . . . . . . 2 3. TIME OF PERFORMANCE . . . . . . . . . . . . . . . . . 2 4. COMPENSATION . . . . . . . . . . . . . . . . . . . . . 2 5. EXTRA WORK . . . . . . . . . . . . . . . . . . . . . . 2 6. METHOD OF PAYMENT . . . . . . . . . . . . . . . . . . 3 7. DISPOSITION OF PLANS, ESTIMATES AND OTHER DOCUMENTS 4 8. INDEMNIFICATION AND HOLD HARMLESS . . . . . . . . . . 5 9. WORKERS' COMPENSATION . . . . . . . . . . . . . . . . 5 10. INSURANCE . . . . . . . . . . . . . . . . . . . . . . 6 11. CERTIFICATES OF INSURANCE; ADDITIONAL INSURED ENDORSEMENTS . . . . . . . . . . . . . . . . . . . . . 7 12. INDEPENDENT CONTRACTOR . . . . . . . . . . . . . . . . 8 13. TERMINATION OF AGREEMENT . . . . . . . . . . . . . . . 8 14. ASSIGNMENT AND SUBCONTRACTING . . . . . . . . . . . . 8 15. COPYRIGHTS/PATENTS . . . . . . . . . . . . . . . . . . 9 16. CITY EMPLOYEES -AND OFFICIALS . . . . . . . . . . . . . 9 17. NOTICES . . . . . . . . . . . . . . . . . . . . . . . 9 18. IMMIGRATION . . . . . . . . . . . . . . . . . . . . 10 19. ENTIRETY . . . . . . . . . . . . . . . . . . . . . . . 10 T r • • AGREEMENT BETWEEN THE CITY OF HUNTINGTON BEACH AND KENNEDY JENKS CONSULTANTS, INC. FOR A MASTER PLAN OF SEWERS THIS AGREEMENT, made and entered into this 15 _6XII of oerAL&� 1992, by and between the CITY OF day HUNTINGTON BEACH, a municipal corporation of the State of California, hereinafter referred to as "CITY," and KENNEDY JENKS CONSULTANTS, INC., a California corporation, hereinafter referred to as "CONTRACTOR." WHEREAS, CITY desires to engage the services of an engineering design contractor to update its Master Plan of Sewers in the City of Huntington Beach; and Pursuant to documentation on file in the office of the City Clerk, the -provisions of HBMC Chapter 3.03, relating to procurement of professional service contracts, has been complied with; and CONTRACTOR has been selected to perform said services, NOW, THEREFORE, it is agreed by CITY and CONTRACTOR as follows: 1. WORK STATEMENT CONTRACTOR shall provide all services as described in the Suc.y 14, CONTRACTOR'S Fee Proposal dated 3e 1, 1992 (hereinafter referred to as Exhibit "A"), which is attached hereto and incorporated into this Agreement by this reference. Said services shall sometimes hereinafter be referred to as "PROJECT." CONTRACTOR hereby designates Roger Null, who shall represent it and be its sole contact and agent in all consultations with CITY during the performance of this Agreement. 9/16/92:sg -1- r 2. CITY_STAFF ASSISTANCE CITY shall assign a staff coordinator to work directly with CONTRACTOR in the performance of this Agreement. 3. TIME OF PERFORMANCE Time is of the essence of this Agreement. The services of the CONTRACTOR are to commence as soon as practicable after the execution of this Agreement and all tasks specified in Exhibit "A" shall be completed no later than August 31, 1993. These times may .r be extended with the written permission of the -CITY. The time for. performance of the tasks identified in Exhibit "A" are generally to be as shown 'in the Scope of- Services" on the Work Program/Project Schedule. This schedule may be amended to benefit the PROJECT if mutually agreed by the CITY and CONTRACTOR. 4. COMPENSATION In consideration of the performance of the engineering services described'in Section 1 above, CITY agrees to pay CONTRACTOR a fee of One Hundred Forty -Three Thousand and no/100 Dollars ($143,000.00). 5. EXTRA WORK In the event CITY requires additional services not included in Exhibit "A," or changes in the scope of services described in Exhibit "A," CONTRACTOR will undertake such work after receiving written authorization from CITY. Additional compensation for such extra work shall be allowed only if the prior written approval of CITY is obtained. 9/16/92:sg -2- 6. METHOD OF PAYMENT A. CONTRACTOR shall be entitled to progress payments toward the fixed fee set forth in Section 4 herein in accordance with the progress and payment schedules set forth in Exhibit A". B. Delivery of work product: A copy of every technical memo and report prepared by CONTRACTOR shall be submitted to the CITY to demonstrate progress toward completion of tasks. In the event CITY rejects or has comments on any such product, CITY shall identify specific requirements for satisfactory completion. Any such product which has not been formally accepted or rejected by CITY shall be deemed accepted. C. The CONTRACTOR shall submit to the CITY an invoice for each progress payment due. Such invoice shall: 1) Reference this Agreement; 2) Describe the services performed; 3) Show the total amount of the payment due; 4) Include.a certification by a principal member of the CONTRACTOR'S firm that the work has been performed in accordance with the provisions of this Agreement; and 5) For all payments include an estimate of the percentage of work completed. Upon submission of any such invoice, if CITY is satisfied that CONTRACTOR is making satisfactory progress toward completion of tasks in accordance with this Agreement, CITY shall promptly approve the invoice, in which event payment shall be made 9116t92:sg -3- • • within thirty (30) days' of receipt of the invoice by CITY. Such approval shall not be unreasonably withheld. If the CITY does not approve an invoice, CITY shall notify CONTRACTOR in writing of the reasons for non -approval, within seven (7) calendar days of receipt of the invoice, and the schedule of performance set forth in Exhibit "A" shall be suspended until the parties agree that past performance by CONTRACTOR is in, or has been brought into compliance, or until this Agreement is terminated pursuant to Section 12 hereof. D. Any billings for extra work or additional services authorized by the CITY shall be invoiced separately to the CITY. Such invoice shall contain all of the information required under paragraph 6C, and in addition shall list the hours expended and hourly rate charged for such time. Such invoices shall be approved by CITY if the work performed is in accordance with the extra work or additional services requested, and if CITY is satisfied that the statement of hours worked and costs incurred is accurate. Such approval shall not be unreasonably withheld. Any dispute between the parties concerning payment of such an invoice shall be treated as separate and apart from the ongoing performance of the remainder of this Agreement. 7. DISPOSITION OF PLANS, ESTIMATES AND OTHER DOCUMENTS CONTRACTOR agrees that all materials prepared hereunder, including all original drawings, designs, reports, both field and office notes, calculations, maps and other documents, shall be turned over to CITY upon termination of this Agreement or upon 9/16/92:sg -4- • • PROJECT completion, whichever shall occur first. In the event this Agreement is terminated, said materials may be used by CITY in the completion of PROJECT or as it otherwise sees fit. Title to said materials shall pass to the CITY upon payment of fees determined to be earned by CONTRACTOR to the point of termination or completion of the PROJECT, whichever is applicable. CONTRACTOR shall be entitled to retain copies of all data prepared hereunder. 8. INDEMNIFICATION AND HOLD HARMLESS CONTRACTOR hereby agrees to indemnify and hold and save harmless CITY, its officers and employees from any and all liability, including any claim of liability and any and all losses or costs arising out of the negligent performance of this agreement by CONTRACTOR, its officers or employees. 9. WORKERS' COMPENSATION CONTRACTOR shall comply with all of the provisions of the Workers' Compensation Insurance and Safety Acts of the State of California, the applicable provisions of Division 4 and 5 of the California Labor Code and all amendments thereto; and all similar state or federal acts or laws applicable; and shall indemnify, defend and hold harmless CITY from and against all claims, demands, payments, suits, actions, proceedings and judgments of every nature and description, including attorney's fees and costs presented, brought or recovered against CITY, for or on account of any liability under any of said acts which may be incurred by reason of any work to be performed by CONTRACTOR under this Agreement. 9/16/92:sg -5- CONTRACTOR shall -obtain and furnish evidence to CITY of maintenance of statutory workers' compensation insurance and employers' liability in an amount of not less than $100,000 bodily injury by accident, each occurrence, $100,000 bodily injury by disease, each employee, and $250,000 bodily injury by disease, policy limit. 10. INSURANCE In addition to the workers' compensation insurance and CONTRACTOR'S covenant to indemnify CITY, CONTRACTOR shall obtain and furnish to CITY the following insurance policies covering the PROJECT: A. General Liability InsUrance. A policy of general public liability insurance, including motor vehicle coverage. Said policy shall indemnify CITY, its officers, agents and employees, while acting within the scope of their duties, against any and all claims of arising out of or in connection with the PROJECT, and shall provide coverage in not less than the following amount; combined single limit bodily injury and property damage, including products/completed operations liability and blanket contractual liability, of $1,000,000 per occurrence. If coverage is provided under a form which includes a designated general aggregate limit, the aggregate limit must be no less than $1,000,000. Said policy shall name CITY, its officers, and employees as Additional Insureds, and shall specifically provide that any other insurance 9/16/92:sg -6- • • coverage which may be applicable to the PROJECT shall be deemed excess coverage and that CONTRACTOR'S insurance shall be primary. B. Professional Liability Instirance,. CONTRACTOR shall acquire a professional liability insurance policy covering the work performed by it hereunder. Said policy shall provide coverage for CONTRACTOR'S professional liability in an amount not less than $500,000 per claim. A claims made policy shall be acceptable. 11. CERTIFICATES OF INSURANCE; ADDITIONAL INSURED_ ENDORSEMENTS Prior to commencing performance of the work hereunder, CONTRACTOR shall furnish to CITY certificates of insurance subject to approval of the City Attorney evidencing the foregoing insurance coverages as required by Sections 9 and 10 herein; said certificates shall provide the name and policy number of each carrier and policy, and shall state that the policy is currently in force and shall promise to provide that such policies will not be cancelled or modified without thirty (30) days prior written notice to CITY. CONTRACTOR shall maintain the foregoing insurance coverages in force until the work under this Agreement is fully completed and accepted by CITY. The requirement for carrying the foregoing insurance coverages shall not derogate from the provisions for indemnification of CITY by CONTRACTOR under Section 8 of this Agreement. CITY or its representative shall at all times have the right to demand the original or a copy of all said policies of 9/16/92:sg -7- • • insurance. CONTRACTOR shall pay, in a prompt and timely manner, the premiums on all insurance hereinabove required. A separate copy of the additional insured endorsement to each of CONTRACTOR'S insurance policies, naming the CITY, its officers and employees as Additional Insureds shall be provided to the City Attorney for approval prior to any payment hereunder. 12. INDEPENDENT CONTRACTOR CONTRACTOR is, and shall be, acting at all times in the performance of this Agreement as an independent contractor. CONTRACTOR shall secure at its expense, and be responsible for any and all payments of all taxes, social security, state disability insurance compensation, unemployment compensation and other payroll deductions for CONTRACTOR and its officers, agents and employees and all business licenses, if any, in connection with the services to be performed hereunder. 13. TERMINATION QAGREEMENT All work required hereunder shall be performed in a good and workmanlike manner. CITY may terminate CONTRACTOR'S services hereunder at any time with or without cause, and whether or not PROJECT is fully complete. Any termination of this Agreement by CITY shall be made in writing through the City Engineer, notice of which shall be delivered to CONTRACTOR as provided in Section 16 herein. 14. ASSIGNMENT AND SUBCONTRACTING This Agreement is a personal service contract and the supervisory work hereunder shall not be delegated by CONTRACTOR to 9/16/92:sg -8- 1S. j GRATIOt� CONTRACTOR shall be responsible for full compliance with the immigration and naturalization Iawa of the United States and shall, in particular, comply with the provisions of 8 U.S.C. 1324a regarding employment verification. 19. ENTIUIX The foregoing, and Exhibit "A" attached hereto, set forth the entire Agreement between the parties. IN WITNESS WHEREOF, the parties hereto have caused this - Agreement to be executed by and through their authorized officers the day, month and year first above written. CONTRACTOR: CITY OF HUNTINGTON BEACH,' KENNIEDY JENKS CONSULTANTS, INC. a municipal corporation . Takaicbd, n- President t laine L.- Hairison, Secretary ATTEST: City Clerk REVIEWED AND A�PRGyP�'% City strator of the State of California Mayor APPROVED AS TO FORM: Z&II-e - S� ?-ti- City Attorney -.,-� ,s.6,'Vg_zs_5z -tt 1- «- 4z. INkTIATED AAp APPROVEC_: P".-IId�z Directlar of Public Works 9/16/92:sg -10- 18. IMMIGRATION CONTRACTOR shall be responsible for full compliance with the immigration and naturalization laws of the United States and shall, in particular, comply with the provisions of 8 U.S.C. S 1324a regarding employment verification. 19. ENTIRETY The foregoing, and Exhibit "A" attached hereto, set forth the entire Agreement between the parties. IN WITNESS WHEREOF, the parties hereto have caused this Agreement to be executed by and through their authorized officers the day, month and year first above written. CONTRACTOR: CITY OF HUNTINGTON BEACH, KENNEDY JENKS CONSULTANTS, INC. a municipal corporation of the State of California Lynn M. Takaichi, Vice President Blaine L. Harrison, Secretary ATTEST: City Clerk IEWED AND APPROVED: City inistrator Mayor APPROVED AS TO FORM: e City Attorney In 9 - A ` 9 z-- INI�IATED AND APPROVED: Directorlof Public Works 9/16/92:sg -10- 14 July 1992 Mr. Steve W. May Principal Engineer City of Huntington Beach Public Works Department 2000 Main Street Huntington Beach, California 92648 Subject: Proposal for Engineering Services Sewer Master Plan Dear Mr. May: Kennedy/Jenks Consultants Engineers and Scientists 17310 Red Hill Avenue, Suite 220 Irvine, California 92714 714-261-1577 FAX 714.261.2134 In response to the City's Request for Proposal dated May 1 1, Kennedy/Jenks Consultants is pleased to submit this updated proposal for engineering services for the preparation of the Sewer Master Plan for the City of Huntington Beach, California. This proposal incorporates our scoping revisions as discussed at the meeting of 10 July 1992 and attempts to format our proposal for inclusion into the City engineering services agreement format. Over the last five years, we have assisted the City with the evaluation and design of two projects: the design of 21,000 linear feet of 20-inch diameter water transmission pipelines and an evaluation and design of seismic renovation improvements to the Peck Reservoir. In addition, Kennedy/Jenks Consultants has recently prepared water/wastewater master plans for several Southern California communities including the Cities of Ontario, Calexico, Fillmore, Santa Paula, Chino, Upland, Montclair, and San Jacinto. In addition, we have prepared rate studies and revenue plans for the Cities of Santa Monica (water and wastewater), Tracy, High - Desert Water District, Fillmore, Susanville Sanitary District, and the Westboro Water/Sewer District. This recent and relevant experience gives our project team insight into the identification and resolution of common deficiencies and problems experienced by Southern California communities. Our well qualified project team also includes Advanced Digital Mapping, which will assist us with development and digitization of sewer record drawing data. We have enjoyed a continuing relationship with many of our planning clients and have provided design and construction services for recommended sewer improvements including: lift stations, treatment plants, and sewer lines. In addition, we have prepared numerous facility operation and maintenance manuals. DMIBIT 'IA" • Mr. Steve W. May City of Huntington Beach 14 July 1992 Page 2 Kennedy/Jenks Consultants We feel confident that our senior level staff has the experience, expertise, and teamwork to perform the sewer master plan and revenue financing plan within the schedule envisioned by the City. We would be pleased to meet with you to discuss our qualifications. Very truly yours, KENNEDY/JENKS CONSULTANTS 7. Roger D. Null Manager of Client Services William R. Bazlen J Branch Manager WRB:ca =IBIT "A" TABLE OF CONTENTS Section Paae PROJECT APPROACH 1.1 PROJECT SCHEDULE 2.1 PROJECT BUDGET, MANPOWER ALLOCATION AND FEE SCHEUDLE 3.1 PROJECT ORGANIZATION 4.1 EXPERIENCE & QUALIFICATIONS 5.1 DESCRIPTION OF PRODUCT 6.1 APPENDICES A - Team Member Biographies B - Sewer System Model (SWRMDL) C - List of City Required Information EMIBIT "A" PROJECT APPROACH The scope and potential implications of the Sewer Master Plan requires that a comprehensive approach be undertaken by the consultant. This comprehensive approach must address key administrative, technical, operational, and financial issues required for the effective management of the City's sewer system. BACKGROUND The City of Huntington Beach is an urban city with a population of approximately 190,000 residents. The City is in the process of preparing a new General Plan to guide the City's future zoning and development. It is for this reason, as well as the need to routinely re- evaluate the infrastructure's ability to meet future demands, that the City has requested proposals for an updated sewer master plan. The planning period will be from present to the year 2010. EXISTING SEWER SYSTEM The City is responsible for operating and maintaining approximately 250 miles of sewer collection system which predominantly consists of 8-inch lines supported by 30 lift stations varying in capacity from 130 gallons per minute (gpm) to 2800 gpm. By contract, sewage treatment and disposal is the responsibility of the Orange County Sanitation -District (OCSD). The City currently operates and funds its sewer utility as a component of the General Fund. Although no sewer user charge exists, the City operates a special fund for the accounting of its sewer connection fee revenues, in compliance with AB 1600. It is the City's desire to develop and implement new sewer service charges and create a new sewer enterprise. OBJECTIVES Kennedy/Jenks Consultants have based the project approach on an understanding of the City's specific objectives. From our discussions with City staff and our understanding of the project issues, the following key objectives have been identified: 0 Develop a project approach with the City as a key team member to support project data gathering, criteria development and sewer system simulation. This approach provides an efficient means of developing a cost effective master plan. • Conduct sufficient field investigation to verify adequacy of existing data for development of the sewer and pumping system model. 0 Develop a digitized map of the sewer and pumping system that can be integrated with the City's current Auto Cadd based right-of-way data file and forthcoming_ Geographic Information System (GIS).. • Evaluate the adequacy of the existing collection and pumping system for current and future flows. 1.1 EXHIBIT "�►" • • • Develop recommended costs for annual operations and maintenance of sewer facilities. • Formulate an easily implementable sewer master plan with prioritized capital improvements. • Present a master plan which can be easily updated by the City. • Conduct a sewer rate study and develop a revenue and financial plan to create equitable sewer service charges and connection fees and establish the basis for a self funded sewer enterprise. SCOPE OF SERVICES The following comprehensive Scope of Services and Project Approach is developed from the Scope of Work presented in the request for proposal (RFP) by the City of Huntington Beach, discussions with City staff, our understanding of the project issues and objectives, and our experience with similar sewer master plans, rate studies and revenue planning projects. De ailed T sk Descri tion A detailed description of each of the tasks follows. Specific subtasks are identified which describe the unique approaches proposed by Kennedy/Jenks Consultants. Task_1 - Planning Data Collection and Review Subtask I.A. - Establish Proiect Goals Meet with the City (1 meeting) to establish project goals, needs, and desires of the proposed study, establish departmental contacts and discuss data availability. Subtask 1.13. - Review of Available Planning and Engineering Documents We will review previous reports by the City of Huntington Beach and/or consultants to the City, relating to population, land use and the previous 1978 Sewer Master Plan. Review shall include the general plan, records/plans from OCSD, City of Seal Beach, Bolsa Chica and the Holly Seacliff Specific Plans, and current mapping of land use and sewer systems available from the City, Engineering and Planning Departments. Subtask 1.C. - Review Zoning Classifications and Sewer Flow Criteria We will review the City's existing zoning, land use and flow data to assess sewage flow/load criteria for appropriate types of user classes. Land use, occupancy densities and population will be reviewed for consistency with metered discharges from the City to the OCSD sewer system. The existing land use data and flow rates identified in existing reports will also be checked to approximate peaking factors, infiltration and inflow, and peak wet weather and peak dry weather flows. The relationship between average sewer flow and peak sewer flow 1.2 F AIBIT "A" will be reviewed and compared to previous Master Plan peak factors, as well as those for comparable Southern California sewerage agencies. The following typical land use types are similar to those used by the City of Huntington Beach for its current and future land use plans: • Residential - Low, Medium, and High Density • Commercial • Industrial • Public Facilities - Parks, Schools, Government, Cemeteries and Churches Subtask J.D. - Assess Non -Huntington Beach Generated Sewage Flgw§ Additional coordination may be required to determine the present and future loading of surrounding municipalities. discharging into key interceptors running through the City or utilizing City pumping stations. Data will be provided by the City from those municipalities or districts contributing flow to the City's system. We understand that this will include the OCSD and the City of Seal Beach. Task 2 - Criteria Develooment and Flow Proiections Subtask 2.A. - Preoare Service Area Mao We will prepare a map showing the study area and proposed limits for sewer service. This task will be closely coordinated with the City's Planning and Engineering staff, as the service area map and associated land use will provide the basis for determining sewer flow projections. The map will be developed using the Auto Cadd data base provided by the City. Subtask 2.B. - Review Population Proiections Population projections and land use data as provided by the City will be documented through the year 2010. A "design population" forecast will be developed in close collaboration with the City Planning Department. The resulting population will be compared with other forecasts for the study area and a rationale given for the selection of the design forecast. Land use projections will be provided by the City staff and will include the user classes identified in Subtask 1.C. above, if appropriate. An annual growth forecast will be prepared through the year 1997 to reflect the number and types of new service connections. This annual growth data will be developed to support the City's need to update capital facilities fees (connection fees) in compliance with AB 1600. Subtask 2.C. - Develop Criteria and Flow Projection We will analyze existing sewer flows by land use type. Peaking ratios will be developed using . City data, existing literature and reviews conducted by Kennedy/Jenks Consultants of. municipalities similar to the City. Design factors will be developed for average and peak flow conditions and will include allowances for infiltration .into the system based upon an assessment of sewer system age, conditions and discussions with City staff. 1.3 EXHIBIT "A" The criteria to be used in the sewer system description and analysis tasks of the project will be documented for review by the City. This is intended to provide the City's staff with an understanding of the plan for estimating existing and future sewer flows. The draft criteria will be finalized after the development and compilation of additional data is derived from field investigations and sewer system flow monitoring (Task 3). Subtask 2.D. - Task 2 Summary and Meeting We will summarize the results of Task 2 and meet with the City 0 meeting) to discuss the results. This meeting will also present our approach to the sewer collection system field investigations including sewer and pumping station evaluation and flow monitoring requirements. Task 3 �- Sewer System Configuration and Model Development SWbJpsk 3.A.1. - DgvgleP Sgwer System Modeling Schematic As discussed with City staff, we propose to use the City's updated atlas as the primary means of identifying and communicating the sewer system to be digitized and modeled. The City will provide a key role in the development of this subtask as a, means of controlling the cost of extracting record drawing data. As discussed with the City, City staff will update the existing sewer atlas with record drawing information (approximately last 5 years) and provide the updated atlas to. Kennedy/Jenks Consultants.: This atlas and other appropriate plans and reports of the existing City's sewer system infrastructure will be reviewed.. Based on this review and discussions with City staff, we will select the appropriate sewer lines to be modeled and develop a proposed sewer system modelling schematic. This schematic will be indicated directly on the sewer atlas and submitted to the City for approval. Upon approval, the City will provide record drawings of the facilities to be digitized and simulated. . 3.A.2 - Develop -Digital -Data File of Sewer System Schematic The recorded drawings submitted by the City in the previous subtask will be reviewed and specific data extracted (i.e. manhole elevations, sewer diameters, and points of connection of lateral sewers). A manhole numbering system with areas segmented into drainage basin quadrants for easy identification and reference will be developed and noted on the sewer atlas. An inspection of up to 40 manholes will be conducted in order to assess depths and direction of flows, debris build-up, depth to inverts and general structural conditions for selected portions of the system. The manhole locations, invert elevations, pipe sizes and lengths and numbering system will be digitized and a sewer system data file will be created. This data file will be merged into the computerized sewer system model. Information concerning computer modeling software proposed for the City's Sewer Master Plan is presented in the Appendix. Subtask 3.A.3. - Develop Sewer System GIS Data File The data file of the facilities representing the sewer system schematic will be developed for incorporation into the City's forthcoming GIS System. The digitized sewer file and their corresponding identification numbers will be adjusted to overlay with the existing Auto Cadd 1.4 E UBIT "A" based right-of-way map and data file provided by the City. As discussed with the City, this data file will require the reconciliation of individual data point locations for correlation with the Auto Cadd file. Subtask 3.6. - Develop Sewer Flows and Model Calibration Data Estimates of current sewage flows shall be made using the land use data and criteria established in Task 1.C., recent water demand data (February and March rains), OCSD plant, land use and monitoring station flows, and supporting flow monitoring data. We will develop a flow monitoring plan to assess actual land use loads and provide model calibration. The plan will include a combination of seven day and/or twenty-four hour composite flow measurements. Flow monitoring will be provided by the City. It is projected this effort would include monitoring at not more than 40 locations to measure flow, velocity and depth. The magnitude of inflow and infiltration can be evaluated only if wet weather is experienced during the duration of this limited program. We assume that the City will provide the pipe size and slope for each monitoring site for calibration of the equipment. The results will be summarized and presented in a type -written report including: average daily flow; daily peak flow; and average hourly flow. Subtask 3.C. - Execute Pumging/Lift Station Ins ec i n Each of the City's thirty pumping stations will be inspected to evaluate the ability to meet existing and projected flow conditions. The inspection/evaluation will address pumping station dimensions, equipment configurations and nameplate data. Current pumping records, provided by the City, will be compared to original pump curves and nameplate data to assess adequacy and performance of each existing pumping station. Existing standby power systems will also be reviewed. The sequencing of pumps in multiplex pump stations will be established for model simulation. It is assumed that the City will provide record drawings of all pumping/lift stations and will provide assistance of operations staff during site inspections. Subtask 3.12 - Task 3 Summary and Meeting We will summarize the results of Task 3 and meet with the City 0 meeting) to discuss the results. Task 4 - Sewer and Pumping System Analysis Subtask 4.A. - Identify Sewer System Deficiencies A meeting will be held with the City building department and operating and engineering staff. to ascertain known problem areas. Capacity problems will be discussed using the system schematic as a basis of reference. 1.5 UMBIT "A" Subtask 4.B. - Model and Analyze Existing Sewer and Pum_ging. System The hydraulic adequacy of the existing system will be analyzed as a multi -step process. The first step is to impose the actual land use sewer flows on the sewer system input file of the computerized modelling program. The modelling simulation will be conducted and the results calibrated with the supporting monitoring data. Once the model is calibrated, actual land use sewer flows will be converted to "design loads" and the system will be re -modeled. This "design loaded" simulation will provide the basis for analyzing existing deficiencies as the model will output the total flow verses capacity for each identified reach. Once set up, the model will be a convenient tool to analyze changes in land use, peaking factors, pipeline diameters and/or build -out conditions. Subtask 4.C. - Compile Existing System Deficiencies Once the "current condition" simulation of design loads is run, a list of existing deficiencies will be compiled and presented to the City. Portions of the system with excess capacity will also be identified. Subtask 4.D. - Model and Analyze Future Sewer and Pumping System The projected ultimate demands at the year 2010 will be imposed on the sewer system model utilizing the land use overlays and sewage flow estimates of previous tasks. The system model will address pumping/lift station capacity and the capability of lift station discharge sewer lines to meet the anticipated flows. An attempt will be made to evaluate alternatives that maximize the use of existing facilities. These alternatives will be discussed for the City's concurrence prior to performing analysis. Subtask 4.E. - R commend Sewer System] morovements Improvements will be recommended to address existing sewer deficiencies and to meet the projected demands in the year 2010. Tables will -be used to summarize pipeline sizes, materials, slope, capacity, design flows, and estimated construction costs and schedule. The recommended improvements will be keyed to a plate for illustration and prioritized according to need, anticipated schedule and costs, and will be separated into cost components of new capacity and existing demands for AB 1600 compliance. Subtask 4.F.- Recommend _Pumping Station System Improvements Based on the results of the inspection program and computer modeling, recommendations will be developed to provide adequate pumping/lift station capacity and identify pumping station improvements. Summary tables will be prepared showing recommended improvements and associated costs. Improvements will be prioritized according to need, anticipated schedule, and costs, and will be segregated for AB 1600 compliance. Subtask 4.G_.-_Provide-Computer Model Training An original version of the hydraulic model and supporting data files will be provided to the City. Training will be provided on the use of the hydraulic model in the form of two half -day 1.6 F�iIBIT "A" workshops with selected City staff. This training will focus on the procedure used to evaluate future alternatives,• modify land use demands and zoning, and replan when new data become available. Subtask 4.H. - Task 4 Summary and Meetina We will summarize the results of Task 4 and meet with the City (1 meeting) to discuss the results. Task 5_-_Develop Onerations and Maintenance Cost Projection Following the system hydraulics evaluation, an operation and maintenance cost estimate will be prepared. This cost estimate will be based on historical costs and incremental increases in growth and compared with similar operation and maintenance programs of other local municipalities and private agencies. Maintenance requirements will be prioritized to focus immediate attention where required. Operation and maintenance costs will also be included in the revenue plan as incremental increases in the. revenue requirements of the existing sewer operational costs and allocated as costs to be recovered through the new sewer user charges. Task 6 -_Submit Sewer Master Plan Documen The information gained through the performance of the previous tasks will be presented to the City as its 1993 Sewer Master Plan. Two (2) copies of the draft report and associated master plan maps will be provided to the City for review. Upon receipt and incorporation of City comments, twenty (20) copies of the final master plan document and original mylars of master plan maps will be prepared and submitted to the City. The master plan documents will include the findings, conclusions and recommendations of the tasks described above, along with appropriate system layouts, graphs, tables, maps, and criteria used in the investigation and analysis of these sewer facilities. The Sewer Revenue and Financing Plan (Task 7) will be prepared and submitted as a separate document. We will also present the result of the study (1 meeting) to the City Council and attend one community meeting 0 meeting). Task 7 - Develop Revenue and Financing Plan The purpose of this task is to provide the City with a revenue/financial plan to fund the capital improvements and operational expense requirements developed in the sewer master plan, perform a five year revenue projection of utility revenue and funding requirements and accomplish the City's financial objectives of a self funded sewer enterprise. The financial plan incorporates the operation and maintenance program recommendations and capital improvement requirements assessed in the Sewer Master Plan. The primary tasks anticipated. to accomplish the financial planning objectives are detailed below: Task 7.A. - Assess Revenue Req_uirerngnts In this task, Kennedy/Jenks Consultants will perform a financial projection to assess revenue and funding requirements for the City's sewer utility. Additionally, we will develop a revenue 1.7 E2HIBIT "A" • 0 program to meet financial obligations in conformance with the State Water Resources Control Board's (SWRCB) "fair and equitable" guidelines. This will be accomplished by performing the following subtasks: Identify and classify budgeted (FY 1992-93) operating and non -operating expenses that should be included in the new sewer enterprise. This classification should include a review of the City's list of capital assets to assess sewer system assets and the associated depreciation expense. 2. Incorporate the operation and maintenance program recommendations assessed in the Master Plan and project the enterprises operating and maintenance expenses including cost of collection and administrative functions. 3. Assess and project the new costs associated with utility billing, collection and administrative functions. 4. Project the increases in the City's sewer treatment expanse by assessing incremental increases in treatment unit costs and incorporating growth and demand information developed in the Master Plan. 5. Incorporate and project the capital improvements program requirements including normal system additions and replacements and extraordinary capital projects as identified by the City and the Master Plan. The impact of additional capital expenditures also requires the projection of new depreciation expense. 6. Assess capital financing and debt service requirements of the City's sewer utility. Debt service requirements will include existing obligations, if any, the conversion of projected capital financing to annual debt expense and the revenue requirements to meet financing conditions of debt coverage ratios and levels of fund balance. 7. Review sources of revenue and other income/funds presently in use and which might be available to fund utility operations and capital improvements. 8. Assess the impact of reduced water consumption on utility revenues and expenses. 9. Construct a five-year financial projection (1993-1999) of operating revenues, operating expenses, debt service, capital expenditures and other sources and uses of funds. To the extent available, we would collect five years of historical data by account numbers on operating expenses, debt service and capital expenditures to assist in performing the financial projection. This will contrast the City's financial position during the past five years with the projection for the next five years. 10. Assess annual cash requirements which define short and long-term needs to increase revenues, obtain financing, etc., for the five year planning period. The financial projection will provide the basis for developing a time -phased financial plan for the City's sewer system in which amounts and timing of user charge revenue increases are defined. The plan will also define utilization of other sources of funds and financing to be 1.8 LIMIT "A" employed to supplement user charge revenue increases. The revenue requirement plan will assist in a discussion of the funding needs of the City's sewer system relative to the customer's sewer requirements, capital improvement plans and operating expenses so that appropriate decisions can be made by the City. Task 7.13. - Allocate Cost of Service In the preceding task, Kennedy/Jenks Consultants will identify the proposed revenue requirements for the City's sewer system operations. In this task, we will perform a sewer cost of service evaluation which allocates sewer system costs to user classes by sewage characteristics (OCSD and/or SWRCB parameters for flow, BOD, and SS), determines rates of return which measure the fairness and equitability of rates charged user classes (residential, commercial, industrial, etc.), and derive unit costs useful in designing appropriate sewer rates and charges. The following subtasks will be performed: 1. Define user classes of service (residential, commercial, industrial, etc.) for the development of unit costs of service and incorporate results in the study. 2. Analyze the sewer system to identify capital investment which could be directly assigned to user classes. 3. List operating expenses by function and percentages of investment in sewer facilities. 4. Classify operating expenses and investment in City sewer facilities to capacity, strength and customer related cost components. This will result in separation of costs reflecting user class capacities, sewage strength (OCSD and/or SWRCB parameters) and customer related costs (such as billing, meter reading, etc.) and includes a breakdown of fixed and variable costs. 5. Develop capacity, strength and customer related allocation factors and allocate costs to user classes. 6. Derive unit capacity, strength and customer costs useful in designing proposed sewer rate structures. 7. Calculate proposed fixed and variable revenue requirements for user classes which reflect costs to serve. The cost of service evaluation will allow the identification of costs of providing sewer service to the different types of users. It enables the City to design and adopt sewer rates which are fair and equitable to each user class and defines the revenue required from each class. Task 7.C. - Evaluatq Ratemaking Concepts In this task, we will evaluate optional ratemaking concepts which could be incorporated into the recommended sewer rate structure. Among these concepts will be the desirability of assessment of sewer charges based on water consumptionto supportwater conservation, and the allocation and recovery of fixed and variable costs. 1.9 =IRIT "A" 0 Task 7.D. -_Develop_and_ Design_Reommended_Sewer_Rates Using the results from previous tasks, this task will address sewer ratemaking issues and design proposed sewer rates. The subtasks to be performed in this task are: 1. Review present sewer rates and rate structures applied to user classes. 2. Recommend sewer ratemaking concepts, including review of the Environmental Protection Agency and State of California Water Resources Control Board Guidelines for developing an appropriate user charge system; connection fees; and, the relationship of fixed to variable costs in developing rate structures. 3. Develop and design sewer rates for the established user classes. 4. Demonstrate the impact of proposed sewer rates on each of the City's user classes. 5. Review, discuss and design sewer connection fees relative to recovery of capital improvement costs, according to the principles of AB 1600. 6. Review and evaluate alternative methodologies of billing adopted sewer rates. This task will design and propose sewer rates and charges which can be adopted by the City to provide funds required to continue sewer operations on a financially sound basis. Task 7.E. - Submit SWRCB Sewer Revenue Program for FY 1993- 4 Based on the results of the sewer rate study, we will prepare the City's Sewer Revenue Program for FY 1992-93 which must be submitted to the SWRCB. To prepare this submittal, we propose to utilize a proprietary computer program called REVPGM which is designed to facilitate the preparation of the SWRCB forms. Task 7.F. - Submit Draft _and Final Resorts In addition to the tasks described herein, Kennedy/Jenks Consultants will perform the following subtasks: 1. Submit five (5) copies of draft report for review by the City. 2. Meet with the City (1 meeting) to review the draft report and present the results to City staff. 3. After incorporation of City review comments, prepare twenty (20) copies of a final - report of the sewer rate study to document the financial projections, ratemaking concepts, cost of service allocation and proposed rates. Task 7.G. - Assist the City with Ordinance Revisions and Support, In addition to the preparation of the Consultants report associated with the development of a revenue and financing plan, we will assist the City in the following subtasks: 1.10 �IIBIT ".A" Review the City's Charter Municipal Code and the OCSD sewer use ordinance to establish legal authority, maintenance and industrial pretreatment requirements and Municipal Code format. 2. Assist the City in the preparation of two (2) Draft Ordinances to create a Sewer Enterprise and establish a new sewer fund. Prepare the document using Word Perfect 5.1 and submit a computer disc of the draft document to the City for in- house modification and finalization. 3. Assist the City in the preparation of a Draft- Ordinance for the administration, management and schedule of charges of the new sewer enterprise. Prepare the document using Word Perfect 5.1 and submit a computer disc of the draft document to the City for in-house modification and finalization. F�iIBIT "A" • • PROJECT SCHEDULE Work can begin immediately after execution of an agreement. We have the experienced personnel and resources needed for this project, and we are prepared to commit the key staff through the successful completion of the City of Huntington Beach's Sewer Master Plan and Revenue Financing Study. Please note that the proposed schedule for the project completion is relatively compressed and dependant upon several factors outside of our control, such as the availability of the required data and City review. Unanticipated delays by these outside factors would prolong the schedule accordingly. The following schedule reflects the number of weeks required to reach the identified milestone from receipt of a notice to proceed (NTP). Milestones are described in our Project Approach Section presented earlier in this proposal. Milestone Description Approximate Weeks from NTP Projected Notice To Proceed (NTP) 0 City Update of Sewer Atlas 8 Task 1 - Planning Data Collection and Review 8 Task 2 - Criteria Development and Flow Projections Task 3 - System Configuration and Model Development City Review of Configuration and Model * Task 4 - Analyze Sewer and Pumping System Task 5 - Project Operations and Maintenance Costs Task 6 - Draft Master Plan City Review of Draft Master Plan Task 6 - Submit Sewer Master Plan Document Task 7 - Develop Revenue Financing Plan City Review of Draft Revenue Financing Plan Task 7 - Submit Final Revenue Financing Plan * Assumes 3 weeks for City review of draft submittals. This schedule is shown graphically on the following page. 2.1 11 14 17 23 25 27 30 33 38 41 44 08/17/92 10/12/9 2 10/12/92 11 /02/92 1 1 /23/92 12/14/92 01 /25/93 02/08/93 02/22/93 03/15/93 04/07/93 04/28/93 05/19/93 06/15/93 EIIBIT "A" SEWER MASTER PLAN SCHEDULE CITY OF HUNTINGTON BEACH WEEKS FROM NOTICE TO PROCEED 12/14/92 _ 3/15/93 5/19/9 TASK/MILESTONE DESCRIPTION NTP 4 8 12 16 " 20 24 28 32 36 40 " 44 Projected Notice To Proceed (NTP) - 8/17/92 City Update of Sewer Atlas xxxxxxxxxxxxxxxx Task 1 - Planning Data Collaction and Review xxxxxxxxxxxxxxxx Task 2 - Criteria Development and Flow Projections xxxxxxxxxxxXxxXxxx Task 3 - System Configuration and Model Development xxxxxxxxxxxxxxxxxxxxx City Review of Configuration and Model Xxxxxxxx Task 4 - Sewer and Pumping System Analysis xxxxxxxxxxxxx Task 5 - Develop Operation and Maintenance Costs xxxxx Task 6 - Submit Draft Sewer Master Plan Documents xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx City Review of Draft Master Plan Documents xxxxxx Task 6 - Submit Final Sewer Master Plan Documents XXXXXXXXX Task 7 - Develop Draft Revenue Financing Plan xxxxxx XXXXXXXXXXX)MXXXXXXXXXXXXX City Review of Revenue Financing Plan xxxxXxx. Task 7 - Develop Final Revenue Financing Plan xxxxxxxx 2.2 IUMMBIT "A" • • PROJECT BUDGET, MANPOWER ALLOCATION AND FEE SCHEDULE In response to the City's Request for Proposal dated May 11, 1992 and the subsequent scoping meeting of 10 July 1992, Kennedy/Jenks Consultants is pleased to submit herewith the estimated fee for engineering services associated with the preparation of the Sewer Master Plan for the City of Huntington Beach, California. As requested, a cost and labor breakdown is provided for each of the tasks detailed in the Project Approach section of our Proposal for Engineering Services. The tasks are summarizes as follows: TASK SUMMARY The proposed Scope of Services is grouped into seven tasks which are generally described as follows: • Task 1.- Planning Data Collection and Review This task will focus on those items identified for review in the City's RFP. • Task Criteria Development and Flow Projections Task 2 will incorporate the information gathered in the previous task and include development of design criteria and flow projections for verification during the measurement and analysis tasks to follow. • Task 3 - Sewer System Configuration and Model Development This task will establish the configuration of the sewer collection and pumping system to be modeled, develop a digitized data input file and incorporate field observations and City provided flow monitoring data for model calibration. • Task 4 - Sewer and PuEnl2ing System An sis Task 4 includes modeling and analyzing the sewer collection and pumping system, identifying current and future system deficiencies, recommending improvements and estimating capital costs. • Task 5 - Develop Operations and Maintenance Cost Projections Task 5 will develop the operations and maintenance costs for inclusion in the revenue financing plan. • Task 6 - Submi Sewer Master Plan Documen Task 6 will consist of compiling work from Tasks 1 - 5 and developing the draft and final master plan documents. 3.1 EYHIBIT ifA" • Task 7 - Develop Revenue end Finanging Plan This task will develop a revenue and financial plan to incorporate the findings of the master plan, design new sewer user charges, update the City's connection fees and assist the City in the creation of a new sewer enterprise. PROJECT BUDGET The proposed fee for the City's Sewer Master Plan is $143,000. This fee is developed from the City's Scope of Work, the detailed Project Approach provided in our proposal and the subsequent scoping meeting of 10 July 1992. Per the City's Request for Proposal (RFP), this total cost is separated into services to be performed under a fixed fee and services (meetings) to be conducted under a time and materials not to exceed (NTE) basis. This project cost is separated as follows: Scope of Services Less Meetings - Lump Sum Fee = $136,000. Seven (7) Project Meetings - Time and Materials NTE = $7,000. Although it is difficult to estimate, we have based the modeling and data digitization labor effort on developing 200 to 250 modeling nodes. The per task labor and cost breakdown and a Schedule of Charges, dated January 1, 1992 for additional services are included on the following pages. 3.2 FMIIBIT "A" CITY OF HUNTINGTON BEACH SEWER SYSTEM MASTER PLAN AND FINANCING PLAN BUDGET ESTIMATE - BILLING CLASSES SUPERVISOR SENIOR GRADE 1 GRADE 2 GRADE 3 DRAFTER WORD HOURS TOTALS $ ENGINEER ENGINEER ENGINEER ENGINEER ENGINEER DESIGNER PROCESS JOB TASKS BILLING RATES $11B S110 595 S83 $05 SM S45 TASK 1-PLANNING DATA COLLECTION & REVIEW Task 1A-Establish Project Goals 4 4 4 0 0 0 2 14 S7,3B2 Task 1 B-Review of Available Documents 0 8 e 12 0 0 2 30 $2,728 Task 1C-Review Zoning & Sewer Flow Criteria 0 4 12 s 0 0 2 28 $2eW Task 1D-Assess Non-CltySewerFiows 0 2 4 8 0 0 2 16 $1,354 Subtotal Task 1 4 18 28 28 0 0 e as $7,796 TASK 2-CRITERIA DEVELOPM ENT AND FLOW PROJECTIONS Task 2A- Prepare ServiceArea Map 0 D 4 0 0 s 0 12 3900 Task 20-Revkrw Population Projection 0 0 4 0 8 0 2 14 5990 Task 2C-Develop Crttadsand Flow Projection 0 2 e 4 16 0 2 32 $2.442 Task 2D-Task 2 Summery and Meeting 4 I 4 0 0 0 2 14 S7'3R Subtotal Task 2 4 s 20 4 24 8 s 72 $5,714 TASK 3-SEWER SYSTEM CONFIGURATION AND MODEL DEV_EiOPMENT Task 3A7 -Develop Sewer Modeling Schematic - 0 2 18 0 40 0 0 58 $4.340 Task 3A2-Digital Data File & Model Schematic 0 2 12 16 32 0 0 92 $4,788 Task 3A3-Develop Sewer System GIS Data File 0 0 4 D 0 20 0 24 $1.890 Task 3B-Develop Sewer Flows & Model Callbration 0 2 e 24 0 O 4 38 $3.152 Task 3C-Execute Pumping System Evaluation 2 8 8 40 0 0 e W S5,55s Task 313-Task 3 Summary and Meeting 4 4 4 O 0 0 2 14 $1,382 Subtotal Task 3 s 18 52 s0 72 20 14 202 S20,878 TASK 4-SEWER AND PUMPING SYSTEM ANALYSIS Task aA-Identify Sewer System Deficiencies 2 4 e 0 D 0 2 18 S1.526 Task 4B-Model & Analyze Existing System 2 e 24 32 80 0 4 150 $11,432 Task 4C-Compile Existing System Deficiencies 2 4 B 1s 0 4 4 38 S3,204 Task 4D-Model & Analyze Future System 2 8 1s 40 0 12 4 82 $8,916 Task 4E -Recommend Sewer System Improvements 2 4 B 18 24 1s is Be $6,054 Task4F-Recommend Pumping Station Improvements 2 4 B B 0 0 4 26 $2,280 Task 40- Provide Computer Model Training 2 0 20 0 0 0 B 30 $2,496 Task 4H-Task 4 Summary and Meeting 4 4 . 4 0 0 0 2 14 MIM Subtotal Task 4 18 38 98 112 104 32 44 442 S35,320 TASK 5-DEVELOP O. AND M. COST PROTECTION 2 e 24 0 0 0 e 3B S3.44e TASK B_ SUBMIT SEWER MASTER PLAN DOCUMENT 4 28 32 0 32 24 24 144 $11.312 TASK 7-DEVELOP REVENUE AND FINANCING PLAN Task 7A-Assess Revenue Requirements 4 80 0 0 18 'O 4 84 58292 Task 7B-Allocate Cost of Service 4 40 0 0 8 0 B 00 S5,752 Task 7C-Evaluarte Ratemaking Concepts 2 12 0 0 0 O 0 14 S1,558 Task 713-Develop & Design Recommended Rates 2 40 0 D 0 O B 50 $4,996 Task 7E-Submit SWRCB Sewer Revenue Program 2 25 0 0 4 0 0 34 S3,570 Task 7F- Submit Drattand Final Reports 4 28 0 0 0 2 1s 50 $4,402 Task 7G -Asalst Ordinance Revisions & Support 4 48 4 0 0 0 1s 72 $8.852 Subtotal Task 7 22 250 4 0 28 2 52 364 $35.425 TOTAL HOURS so 3W 250 224 290 Be 154 1,405 TAL DOLLARS $7,000 $40,4BO $24,320 $18,592 $18,9D0 $5,590 Ss,930 S119,892 AL QUALITY CONTROLIASSURANCE 20 0 0 0 0 0 0 20 $2,3s0 DJECT MANAGEMENT 0 80 0 0 0 0 0 BO $9.0w HER DIRECT COSTS S2,148 13CONSULTANT - ADVANCED DIGITAL MAPPING S12.000 TOTAL SEWER SYSTEM MASTER PLAN BUDGET ESTIMATE $143.000 • Is Client/Address: City of Ountington Beach 2000 Main Street, P.O. Box 190 Huntington Beach, CA 92648 Contract/Proposal Date: 14 July 1992 Schedule of Charges Personnel Compensation Classification tennedy/Jenks Consultants Hourly Rate Drafter[Technician .......... ................ $ 52 Designer/Senior Technican ..................... 65 Engineer -Scientist, Grade 3 ..................... 65 Engineer -Scientist: Grade 2 .................. .. 83 Engineer -Scientist: Grade 1 .............. . ...... 95 Senior Engineer -Scientist ..... . ................ . 110 Supervising Engineer -Scientist ......... . .........118 Principal/Consultant ........................... 125 Laboratory Analyst .......... .......... ...... 53 Word Processor ............................... 45 Non -Technical` .............................. 35 January 1, 1992 Nan-techn cal ti-re will be charged only for preparation of technical repors and similar material and does not app;y to routine adm-nistrative-type activities. Direct Expenses Reimbursement for direct expenses, as listed below, incurred in connection with the work, will be at cost plus ten percent for items such as: a. Maps, photographs, reproductions, printing, equipment rental, and special supplies related to the work. b. Consultants, soils engineers, surveyors, contractors, and other outside services_ c. Rented vehicles, local public transportation and taxis, travel and subsistence. d. Telecommunications and delivery charges. e. Special fees, insurance, permits, and licenses applicable to the work f. Outside computer processing, computation, and proprietary programs purchased for the work. Reimbursement for owned automobiles, except trucks and four-wheel drive vehicles, used in connection with the work will be at the rate of 3511 per mile. The rate for trucks and four-wheel drive vehicles will be $25 per day and 40" per mile. Reimbursement 'or use of microcomputers will be at the rate of $10 per hour. Reimbursement for use of computerized dra"ing systems (CADD) wi',' be at the rate of S20 per hour for microcomputer based systems and $40 per hour for minicomputer based systems. Rate for professional staff for legal proceedings or as expert witnesses will be at a rate one and one-half times the Hourly Rates specified above. In-house laboratory anaysis, samp'ng vehicle, and equ;oment charges will be per current rate schedule or special quotat on. Excise and gross receipts taxes, if any, will be added as a direct expense. Additional processing charges will be added for other than standard invoice backup documentation The foregoing Schedule of Charges is incorporated into the agreement for the services provided, effective December 21, 1991 through December 18, 1992. After December 18, 1992, invoices will reflect the Schedule of Charges currently in effect. EMMMBIT "A" PROJECT ORGANIZATION Kennedy/Jenks Consultants is a multidisciplinary environmental engineering firm which has been providing consulting services continuously for over 70 years. The firm's available staff includes civil, sanitary, mechanical, electrical, structural, geotechnical, environmental and chemical engineers holding professional registrations in more than 20 states and territories. Other staff include architects, chemists, biologists, rate specialists and air quality scientists. The firm's collective staff experience covers all phases of project planning, design, and construction management and utility financial planning. This section describes the project team and the organizational structure we propose for the successful completion of the comprehensive Sewer Master Plan. Specific detailed experience and qualifications of key project team members are presented in the Appendix. We propose to assemble a particularly well qualified project team to prepare the.Sewer Master Plan and revenue financing plan for the City. Since a relatively broad range of skills and services is required, we propose to use engineers, planners, and rate specialists to perform the work. This team of senior level staff has significant recent experience in preparing sewer master plans, pumping system evaluations, and rate and revenue plans. This team will efficiently combine the analytical components of the sewer master plan with the data requirements and analysis of the revenue and financing study. This efficiency is essential to the success of the City's Sewer Master Plan. The following paragraphs describe the project team members, their responsibilities, and qualifications. A project organization chart is provided at the conclusion of this section. Lynn M. Takaichi - Officer in Charge Mr. Lynn M. Takaichi will serve as the Officer in Charge of this study. In this capacity, he will assist the Project Manager with the administration of the project contract and support the resource allocation to the project. Mr. Takaichi has served in this capacity on many master planning and financial studies. As the District Engineer for the Castaic Lake Water Agency, he is experienced with the many issues involved in long range planning, such as: development of capital and operational costs, development of utility rate and revenue/financial plans, understanding legal authority issues, and the preparation of ordinances for utility management and administration. Roger D. Null - Project Manager The project will be organized under the direction of Mr. Roger D. Null. As Project Manager, Mr. Null will coordinate all administrative and management functions to assure that adequate staffing and other resources are available to complete the work on schedule. He will also be 4.1 =IBIT "A" responsible for the technical execution of the revenue and financial component of the proposed study and will manage the preparation of the Sewer Master Plan to assure it is conducted to the level of detail required for use in the revenue and financing element of the study. Mr. Null has served in this capacity on many recent master planning and financial studies. He has over 15 years of experience, and specializes in utility planning and the development of utility rate and revenue plans and municipal ordinances. In the last two years, Mr. Null has completed eight water/wastewater rate and revenue studies, and managed two utility master plans. These master planning projects have included system digitization for GIS compatability, system modeling and development of CIPs for AB 1600 compliance; while the rate and revenue studies have included development of new ordinances, assessment of water conservation rate structures, assessment of utility system billing requirements, development of rates, connection fees and revenue programs, and development and projection of utility operational costs. Harold B. Tennant, P.E. - Technical Advisor and QA/QC Mr. Harold B. Tennant will perform the Quality Assurance/Quality Control review of the work in progress. Mr. Tennant, one of our firm's senior staff members, will provide technical support to the project team. He has over 30 years of experience with the planning, design, and construction management phases of engineering projects and has worked on numerous planning and design efforts related to wastewater facilities. As Chief Engineer of our firm's Southern California offices, Mr. Tennant manages the firms's overall quality control and technical review program. Craig W. Lichty, P.E. - Project Engineer Mr. Craig W. Lichty will serve as the project engineer for the preparation of the Sewer Master Plan. In this capacity, he will be instrumental in the development of criteria, flow projections, development and calibration of the sewer model, and development of a prioritized short- and long-term capital improvement plan. Mr. Lichty has over ten years of experience in the planning, design, and construction of sewer conveyance, pumping, treatment and disposal systems. Within the last three years, Mr. Lichty has completed a Wastewater Collection, Treatment, and Disposal Feasibility Study for the City of Fillmore, a Sewer Master Plan for the City of Santa Paula, a Wastewater Engineering Study for the Ventura Regional Sanitation District, and an update to the City of Fillmore Sewer Master Plan. These projects typically include: establishment of land use and growth projections, sewer flow monitoring, development of a collection system computer model, evaluation of existing facilities, and recommendations for a facilities improvement plan. 4.2 EMMMBIT "A" Jonathan B. Howard - Staff Engineer_ - Flow Criteria, Projections, Collection System Hydraulics and Modelling Mr. ,Jonathan B. Howard will support the team in the evaluation of existing population and land use data, establishing flow criteria, and projecting sewer flows. He will assist in the development of future sewer flows using the City's existing population growth rates, land use projections, and future development plans. In addition, he will interface with the data development and GIS subconsultant to establish the configuration and characteristics of the system for the computer model, and will evaluate the model to recommend capital improvements to address current and future collection and pumping system deficiencies. Mr. Howard is experienced in the planning, design, and construction of sewer systems. Mr. Howard assisted in the development of the software for computer modeling performed as part of the Wastewater Collection, Treatment, and Disposal Feasibility Study for the City of Fillmore, and has conducted numerous computer modelling projects. Mr. John M. Wyckoff, P.E. - Sanitary Engineer - Pumping System Analysis Mr. John M. Wyckoff will establish the physical condition and capacity of the City's pumping stations through physical inspections, will investigate the.availability of standby power, and will develop pumping system cost estimates. Mr. Wyckoff has over 15 years experience in sanitary engineering and has specialized expertise with system hydraulic evaluations and design of wastewater pumping systems. He has recently performed the evaluation and design for replacement of three pumping systems for the Central Marin Sanitation Agency. The project included design of a new pumping system that provides flow equalization and can simultaneously pump to separate locations at varying flow rates. Advanced Digital Mapping - Data Development and GIS Advanced Digital Mapping (ADM) will provide efficient and cost effective support to the project through the extraction and digitization of record drawing information and the development of the digital layer interface with the City's Auto Cadd based right-of-way file. ADM will work closely with the project team to extract and input sewer system data (pipe length, slope, and manhole depths) and input the corresponding manhole numbering system. ADM is a specialized mapping firm with significant experience in data development and conversion form one media source to another. ADM has provided similar services on other utility master planning and record drawing digitization projects. As discussed with the City, biographies of all team members and subconsultants are provided in the Appendix. 4.3 EXHIBIT "All SEWER MASTER PLAN ORGANIZATION CHART Kennedy/Jenks Consultants CITY OF HUNTINGTON BEACH Steve W. May Principal Engineer OFFICER IN CHARGE Lynn M. Takaichi PROJECT MANAGER Roger D. Null PROJECT ENGINEER Craig W. Lichty STAFF ENGINEERS Jonathan B. Howard Flow Criteria, Projections & Modelling John M. Wyckoff Pumping Systems Evaluation TECHNICAL REVIEW/OA OC Harold B. Tennent SUBCONSULTANT Advanced Digital Mapping Data Development and CIS IMMIT "A" EXPERIENCE AND QUALIFICATIONS This section of our proposal discusses our firm's overall experience, technical competence, and capabilities needed to prepare the Sewer System Master Plan for the City of Huntington Beach. In addition, descriptive materials in other key areas are included. In providing our relevant experience for this project, we would like to emphasize the following key points: • Kennedy/Jenks Consultants has a proven track record of engineering performance since 1917. During this time, we have successfully completed over 3,500 projects, with a significant number of these projects being in the field of analysis and planning of water and wastewater systems. • We have previously worked with the City on two projects. In the last five years, we have desigged approximately 4 miles of 20-inch water transmission pipelines in the downtwon area and evaluated and designed improvements to the Peck Reservoir. • Through discussions with City staff and a review of the City's latest sewer master planning and selected video inspection efforts, we have developed a fundamental understanding of the City's sewer system and the availability of data to accomplish the required services. • Kennedy/Jenks Consultants has adapted "off -the -shelf" computer programs to evaluate water and wastewater systems which provide an efficient and cost- effective means of identifying system deficiencies and expansion alternatives. • Kennedy/Jenks Consultants has assembled a project team which is well experienced in the areas of expertise required to accomplish the Scope of Services. GENERAL TECHNICAL CAPABILITIES Kennedy/Jenks Consultants is a multidisciplinary environmental engineering firm which has been providing consulting services continuously for nearly 70 years. The firm's staff of over 400 includes civil, chemical, mechanical, electrical, structural, construction and environmental engineers holding professional registrations in more than 20 states and territories. Other specialists include architects, chemists, biologists, toxicologists, hydrologists, rate specialists, and air quality scientists. The firm's collective staff experience covers all phases of project planning, design, construction management and utility financial planning. Our firm maintains regional offices in several West Coast and Pacific cities: Irvine, Ventura, San Diego, San Francisco, Palo Alto, Sacramento, and Bakersfield, California; Reno, and Carson City, Nevada; and Seattle -Tacoma, Washington. CLIENT REFERENCES Mr. Stan Scholl Director of Public Services City of Santa Monica 1685 Main Street Santa Monica, California (310) 458-8221 Mr. Kelly Polk Special Project Manager Ventura Regional Sanitation District/ City of Fillmore 90401 1001 partridge Drive, Suit 150 Ventura, California 93003 (805) 658-4661 5.1 EMUBIT IV A VV VA" The project objectives, previously addressed in this proposal, identified key issues associated with the successful accomplishment of the City's Sewer Master Plan and associated revenue financing plan. Based upon these issues, we have identified the following categories necessary to effectively perform this project and to provide additional services that may be required by the City. Other relevant experience is presented in the following sections. • Sewer System Master Planning Experience • Sewer Rate and Revenue Programs SEWER SYSTEM MASTER PLANNING EXPERIENCE Kennedy/Jenks Consultants experience in the planning and design of sewer collection facilities has included analysis of the existing system and conceptual layout of future systems for expansion or improvement purposes. Long-range planning has included population projections, system demands, projected flow requirements, determinations of existing capacity, measurement of infiltration/inflow, overflow and exfiltration, and identification of deficiencies. In addition, we have prepared cost estimates and implementation schedules for the renovation and replacement of collection systems and provided financial planning to assist our clients in implementing planned projects. Sewer System Master Plan City of Ontario, a i ornia Kennedy/Jenks Consultants was recently selected by the City of Ontario to conduct a sewer master plan of the City's 40 square miles of infrastructure. The purpose of this project was to analyze and evaluate the impact of the City's ten year growth requirements on the existing sewer system and assess maximum flow requirements at total City build -out. The project included the development of a digitized utility system data base and its integration with City ARC -INFO based GIS system, the development of current and projected land use loading factors, the development of a computerized sewer system model to analyze over 150 drainage basins, a flow monitoring plan for model and loading factor calibration, the evaluation of sewer capacity deficiencies and utility replacement program, and the development of a phased capital improvement program. Project Participant: Roger Null Sewer System Master Plan City of Santa Paula, California Kennedy/Jenks Consultants recently completed a sewer master plan for the City of Santa Paula. The data collection phase included review of sewer line maintenance records, as -built plans of the collection system, and interviews of City staff to identify maintenance problems within the system. Land use information and annual treatment plant flow records were also collected to identify system -wide infiltration/inflow and to provide a basis for estimating sewage flows from sewer service areas within the City. A second phase included an above- ground inspection of sewer system manholes to determine their condition, measure sewage flows, and to get an indication of the condition of the sewer pipelines based upon their condition at the manholes. The flow monitoring phase included selecting locations within the collection system for monitoring of sewage flows during peak wet weather flow conditions. Wastewater flows were continuously recorded during this phase. The last phase consisted of a television inspection of selected sewer lines followed by submittal of final master plan documents. Project Participants: Lynn M. Takaichi, Harold B. Tennant and Craig Lichty 5.2 =IBIT "A" Sewer System Master Plan Cily of Fillm re C lifornia Kennedy/Jenks Consultants conducted a sewer master plan to evaluate the existing condition of the City's sewage collection system capacity and assist the City in planning for future infrastructure needs. The project included determining actual flow conditions, documenting land use projections and population, modeling of the sewer system and development of a revenue program and capital improvement program. Sewer system alternatives were analyzed to consider diverting flows in order to optimize the utilization of the existing system. Project Participants: Lynn M. Takaichi, Harold B. Tennant and Craig Lichty Sewer System Mager Plan City of Calexico California Kennedy/Jenks Consultants was retained to provide a 20-year Master Plan of Wastewater Facilities for the City of Calexico. As a community of 20,000 residents, Calexico is experiencing rapid growth estimates to have a population of 40,000 by 2005. The City had several trunk sewers at capacity and had reached capacity in its wastewater treatment facilities. Kennedy/Jenks Consultants prepared a comprehensive master plan of wastewater facilities which included documentation of all sewers with the City, preparation of sewer system maps showing each sewer and sewage lift stations within the City and analysis of the existing system. The master plan determined available capacity within the sewer system and provided for a detailed plan of sewer improvements. These improvements were necessary to accommodate near -term developments in manufacturing and commercial industries as well as long-term residential development within the City. Kennedy/Jenks Consultants also prepared a comprehensive financial plan in order to establish a workable capital improvement program for the City's near -term development and establish available financing mechanisms for the City's 20-year development plan. Project Participants: Lynn M. Takaichi and Harold B. Tennant Wastewater Utility Management Plan City of Henderson, Nevada Kennedy/Jenks Consultants prepared a twenty year wastewater utility management plan for the City of Henderson to provide them with a flexible planning tool for forecasting the schedule and cost of new collection facility requirements. The project involved selection of flow and population parameters, development of peaking factors curves, modeling of the existing collection system and computer forecasting for identifying and prioritizing the capital improvement requirements. The computer model was provided to the City for ongoing development of "what if" scenarios. Project Participant: Roger Null Unit W_(Phase 1) Improvements City of Thousand Oaks Thousand Oaks C lifornia Kennedy/Jenks Consultants was responsible for field and television inspection of approxi- mately 7,000 feet of 18- through 36-inch diameter gravity trunk sewer, and field inspection of 3,000 feet of 30-inch diameter pressure sewer and six collector sewers suspended on the side of a canyon. Kennedy/Jenks Consultants developed and evaluated alternatives for 5.3 FKHIBIT "A" rehabilitation of the facilities, including slip -lining, in -place reconstruction, repair, replacement, and rerouting of existing facilities. Conceptual designs, cost estimates, and an implementation plan were developed for the recommended alternatives. Estimated capital cost for the project is approximately $3.1 million, with an estimated completion date of mid-1994. Project Participant: Johnathon B. Howard om reh nsive Sew ra a Plan Pierce County. Washington . Kennedy/Jenks Consultants has completed the development of a total drainage basin sewerage plan and implementation program for an $84 million wastewater facilities program which will provide sewers for an 85-square-mile service area. The facilities include sewage collection systems, pump stations, and major interceptors, ranging in size from 8-inch collection systems to 54-inch interceptors. A computer program was utilized for the system analysis, assessment proceedings and for design. The implementation phase was started in 1972 and an Environmental Impact Statement for a major current phase was completed. This project has included joint projects for consolidation of service with the City of Tacoma to provide the sewering of unsewered areas. Project Participant: Harold B. Tennant C si as Springs Wastewater Collec ion S st m Oak View Sanitary District Oak View. California Kennedy/Jenks Consultants performed engineering services for the proposed Casitas Springs Wastewater Collection System. The system would consist of approximately 7,400 feet of 8-inch gravity sewer pipeline and would serve 150 parcels, primarily residential. Branched sewer pipelines are included to provide all parcels with reasonable accessibility to the sewer system. The facility plan included an area reconnaissance survey, projection of future flows, evaluation of alternative system .layouts, and a recommended final system layout and estimated construction cost. Alternative financing methods, including assessment district and certificates of participation were studied. CEQA documents were prepared for this proposed collection System. Project Participant: Lynn M. Takaichi Exfil ra i n Ou flow Study, South Tahoe Public L )tility District North Tahoe Public Utility District Tahoe City Public Utility District South Lake Tahoe California Kennedy/Jenks Consultants conducted an extensive evaluation of sewers for three separate districts in the Tahoe Basin to determine if wastewater from sanitary sewers could be leaking and contributing nutrients to Lake Tahoe. We conducted a comprehensive field investigation of approximately 26,000 feet of sewer main and 20,000 feet of laterals. The investigation included smoke testing of sewers and a two-phase flow study. During the first phase, flumes were placed in selected manholes typifying drainage areas, and flow measurements were made during the wet and dry seasons. Results indicated that more extensive flow monitoring and a TV inspection of sewers were needed. These studies were performed during Phase 11. In addition to conducting field investigations, we prepared a study report which evaluated 5.4 M_MBIT 'vA'r alternative sewer repair and replacement measures and recommended specific correction actions. These actions included sewer repair by slip lining, replacement of badly damaged sewers, and manhole repairs. We recently completed design specifications for these measures and are scheduled to provide partial construction management services. Project Participant: Harold B. Tennant Wastewater Flow-Stud�c California Institution_for Women California Denar ment of Corrections Chino. Calif nia Kennedy/Jenks Consultants recently completed a wastewater flow study for the California Department of Corrections at the California Institute for Women. The purpose of the flow study was to verify current wastewater flows, develop flow generation factors and assess the accuracy of the flow monitoring equipment. SEWER RATE STUDIES AND REVENUE PROGRAMS The staff of Kennedy/Jenks Consultants are experienced in the development of rates, cost of service allocations and design of revenue programs. This experience includes determination of revenue and funding requirements, financial and load forecasts, implementation of water sampling plans, sampling design and interpretation of results, allocations of costs of service (capital costs and operating expenses) to user classes, rate of return analysis, analysis of alternative ratemaking concepts including water conservation, development of user charge systems and rates, review of allocation procedures for common support costs, development of capital facility charges (connection fees) in compliance with AB 1600, billing system implementation support and assistance with financial bonding. Several of these projects are listed below. Wastewater Rae Study and Revenue Program City of Santa Monica Santa Monica. California Kennedy/Jenks Consultants was engaged to prepare a wastewater revenue program for the City of Santa Monica to a $68 million revenue bonding program. This project involved the design of wastewater user rates for residential, commercial and industrial users and the development of capital facility charges for AB 1600 compliance. These rates were developed from a detailed cost of service analysis where costs were parameterized in terms of both quantity and quality of flow. Final rates were designed to support water conservation with a variable rate component, while the fixed component was distributed within customer the customer class based on water meter size. The cost of service analysis and subsequent revenue program were prepared in accordance with the State of California Water Resources Control Board. • Assistance was provided in the preparation and presentation of rate and financial information to the municipal bond rating agencies and public forums. Project Participants: Roger Null and Lynn M. Takaichi 5.5 =IBIT "A" Wastewater _Rate_and_Study Revenue Program_ 5usanville Consolidated Sanitary District Susanville. California In conjunction with a wastewater master plan, Kennedy/Jenks Consultants developed a revenue and financial plan for the effective implementation of the recommended capital improvement costs. The revenue plan assessed the rate and revenue impact of new growth and incremental increases in costs for the projected 5 year planning period and .researched applicable grants to assist in the financing of unsewered areas. The capital costs associated with the septic system conversion, were converted to debt service and a revenue plan developed to include unique connection fees and surcharges for each of the annexation areas. These costs were developed in compliance with AB 1600. Project Participant: Roger Null Wastewater Rates Study Coachella Sanitary District City of Coachella, California Kennedy/Jenks Consultants conducted a review of the financial condition of the Coachella Sanitary District and a Wastewater Rates Study in anticipation of the expansion of the Wastewater Treatment System capacity. The study consisted of a review of current revenue requirements, a study of future revenue requirements and the development of a recommended revenue plan. In addition to the existing fixed rate structure, variable rate structures based upon the amount of water usage were examined. Assistance to the Coachella Sanitary District was also provided in evaluating mechanisms for financing approximately $2,500,000 in capital improvements. Certificates of Participation were subsequently obtained at very favorable terms. Project Participant: Lynn M. Takaichi Water and Sewer Revenue Program Westboro Municipal Water District Project included the development of a capital asset inventory of water and sewer facilities, the development of current replacement cost and current levels of accumulated depreciation. in - conjunction with this capital asset replacement study, the project included the development of a water and sewer revenue program to assess the required impact of the capital replacement program on existing rates, an assessment of District funding opportunities and use of capital reserve funds for rate stabilization. Project Participant: Roger Null 5.6 IMMIT "A" • • DESCRIPTION OF PRODUCT TO describe the final product, the proposed project team has developed a draft table of contents for the City of Huntington Beach's Sewer Master Plan. This table of contents is based on our project understanding, the City's Scope of Work, our proposed Project Approach and our experience on similar projects and is shown as follows: SEWER SYSTEM MASTER PLAN DRAFT TABLE OF CONTENTS Ch�p�#er Title EXECUTIVE SUMMARY 1 INTRODUCTION Background Authorization Scope of Service Conduct of the Study Abbreviations and Definitions 2 STUDY AREA, LAND USE AND POPULATION Study Area Existing Boundaries Study Area Description Land Use Existing Land Use Ultimate Land Use Land Use Development Projections Population Historical and Current Population Future Population Projections 6.1 EMIMIT "A" 3 EXISTING SEWER SYSTEM System Overview City Drainage Basins Orange County Sanitation District (OCSD) Existing Collection System Existing Pumping Station System Existing Pumping Station System Deficiencies Flow Metering Collection System Pipe Conditions Existing Collection System Deficiencies Sewer System Design Criteria 4 SEWER FLOWS General Historical Sewer Flows Seasonal Fluctuation Peaking Factor Criteria Infiltration/inflow Field Investigation and Flow Monitoring Sewer Loadings Residential Commercial Industrial Public/institutional Open Space Non City Flows Flow Verification Water Conservation Impacts Projected Sewer Flows 5 ANALYSIS OF EXISTING SEWER FACILITIES Analysis of the Existing Collection System Development of Hydraulic Computer Model Hydraulic Modeling Schematic OCSD Trunk System Pumping Station Testing and Analysis Existing System Deficiencies and Potential Problem Areas Summary Analysis of Pumping Station System Current Loads Projected Loads Summary 6.2 MMIBIT "A" 6 PROPOSED SEWER SYSTEM IMPROVEMENTS Approach to Developing System Improvements Overview of Design Criteria, Facility Deficiencies and Proposed .System Improvements System Deficiencies Existing Deficiencies Projected Deficiencies Recommended Sewer System Improvements Recommended System Improvements Schedule and Cost Estimates AB 1600 Capital Improvement Allocation Recommended Operation and Maintenance Costs 7 REVENUE AND FINANCING PLAN Current Revenue Requirements Historical Revenues and Expenses FY 1992-93 Operating and Capital Future Revenue Requirements Customer Growth and Sewer Flow Operating Expense Projections Capital Expenditures Financing Plan Debt Service Requirements Potential Sources of Revenues Present Sewer Rates Proposed Sewer Rates Present Capital Facility Charges Proposed Capital Facility Charges Summary of Proposed Sewer Rates APPENDICES A Sewer System Inventory Listing B Hydraulic Modeling Computer Data C Flow Monitoring Data D Pump Station Pump Curves E Ordinances of Sewer Rates and Charges 6.3 Budget Projections E HIBIT 'RA"